Report FPS2ol5-oo,/8 T 7233 sw eee Ld EJELZ14795 S.W. 72nd Avenue PORTLAND. OR 97224 PHONE 503-620-4020 FIRE, C■ FAX CCB#6414 RECEIVED D JUL 2 g Z015 CITY OF TIGARD BUILDING DIVISION Nuance System Portland, OR DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM July 13, 2015 DELTA FIRE, INC. PROJECT # 15-5462 FIRE PROTECTION CONTRACTORS Nuance Systems July 13,2015 Page 2 of 2 i TABLE OF CONTENTS Pipe & Fittings Steel Pipe Ductile Iron Screwed Fittings Victaulic Coupling Style#05 Victaulic Mechanical Tee Style#922 Hangers, Anvil Ring Hanger Anvil Threaded Rod Sammy GST20 Vertical Screw Sammy SWG20 Horizontal Screw Sprinkler Heads Reliable Model F I FR-56 '/z"200 Degree Chrome Upright Reliable Model F 1FR-56 Y2" 155 Degree Chrome Pendent Reliable Model F 1FR-56 !/2" 135 Degree Chrome Upright Flexhead Braided Flex Drop Y2"x 48" FIRE PROTECTION CONTRACTORS 14795 S.W. 72" D E t PORT A D, OR 97224e PHONE 503-620-4020 FIRE, INC. FAX CCB# 64 674-1 0 58 i • e & F ' ttin s FIRE PROTECTION CONTRACTORS INUII'INUfCN _=Pipe and Supply Corp. Pipe Specification A135 Specification A135 NPS 1/4--30", Schedules 10, 40 and XL THD, Lightwall Scope Covers two grades of electric resistance welded steel pipe. Grade A is adapted for flanging and bending and is suitable for welding. Purpose for which pipe is intended should be stated on order. Kinds of Steel Permitted Open-hearth Basic-oxygen For Pipe Material Electric-furnace Permissible Variations The minimum wall thickness at any point shall not be more than 12.5%under the nominal wall thickness specified. in Wall Thickness Threadable,lightwall(XL)must meet manufacturers minimums. Chemical C max°A° Mn max% P max% S max% Requirements Seamless or ERW Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Tensile Grade A Grade B Requirements Tensile Strength,min.,psi 48,000 60,000 Yield Strength,min.,psi 30,000 35,000 NDE& Hydrostatic inspection test pressures for plain end and threaded are specified. Hydrostatic pressure shall be maintained Hydrostatic for not less than 5 seconds for all sizes of electric resistance weld pipe. Non-destructive electric test should be in accordance Testing with practices E213,method E227 or practice E213. Permissible Variations Plus or Minus 10%schedule 10 in Weights per Foot Plus 10%minus 3 1/2%schedule 40 Permissible Variations Plus or minus 1% in Outside Diameter Mechanical Tests Tensile Test--Transverse returned on pipe NPS 8 and larger. Specified Flattening test--Three steps required with weld located 0°or 90°from the line of direction of force required. Number of Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style. Tests Required Lengths Pipe shall be furnished in 38'with a minimum of 20 ft. Pipe furnished to schedule 10 shall be in a specified length between 16 and 22 ft. Required Markings Rolled,Stamped or Stenciled(Mfgrs.Option) on Each Length Name or brand of manufacturer. (On Tags attached to Kind of pipe,that is,electric-resistance welded A,electric welded B,same schedule wall thickness,schedule 10 or 40,NL each Bundle in case ASTM A135 of Bundled Pipe) Length of pipe. General End finish may be plain end beveled or plain end square cut. Information r 90° ELBOW (:,,:�wiL (/ v Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & fu, FM Approved for 500 psi service. .i 4 1 i Ductile iron per ASTM A536 Class 65-45-12. °e Dimensions conform to ASME B16.3 .< Threads are NPT per ANSI/ASME B1,20,1, NOTICE,Ductile iron listings have higher tensile strength than Shot of steel pipe,Therefore,over rigleening oon cane damage io pipe Crawls which may cause leakage Ductile iron littirits should be lightened three turns beyond hand light,but no more thou lour sums COO 4> Illiffil APPROYea Sera ELBOW fYt e,4 o4rilarburnNMN MY W M M Y M9 .*Fkvm WT o, CO p Nominal Sire Max.Working Dimensions Approx. Pressures A g WI.Each In.(mm) P51 fkl'al 1n.maul ln.(ran) Ms.t1g1 .—A 1m_...�,�.—.,.- 500 1.50 1.50^ 0.62 450 _ Je t,,, 028 r 1% 500 1.75 1.75 0.90 -t IF - 32 3450 4e45 4445 e4' B isi 500 1.94 1.94 1.20 40 3450 4.9..24 0276 0.54 __ 2 500 2.25 2.25 1.65 50 3450 SIPS _',, A-Working Pressure Ratings are for reference only and based on S ..a0 pipe.For the Iwcs+ULRAC. and FM pre ore ratings versus pipe schnduio,please visit on.iiirrtl.aom at conlocl your local Anvil Represenloiwe. 45° ELBOW + ia 14uvi1; C{spFiaNv.. ' Ductile Iron MATERIAL SPECIFICATIONS 1 `� Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. '' Ductile iron per ASTM A536 Class 65-45.12. ug,l Dimensions conform to ASME B 16,3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE:Duchle iron fittings hove higher tensile strength than that of steel pipe.Therefore,over tightening con cue damage to pipe threods which may cause leakage.Ductile iron fillings should be tightened three terns beyond bond tight,but no more thou lour tarns. egK REM APPROVES 45' ELBOW I'm Lni..,a+'Mr4+a thrNas and LVM»rm. wo uo an k... it V.,.Jorleb ecreio lA-rw Nominal Size Mex.Working Dimensions Approx.. Pressures A 13 WI.Each Mired PS!(kPe) In.(Wool h.(owl) IM.(kg) $ i.(m 1 500 1.12 1.12 0.46 r 114 500 1.29 1,29 0.73 ,r Ji 32.I6 f.i! ' A -i I K 500 1.43 1.43 0.92 ; 11111111111111111 40 3a,;+ 36 32 2 500 1,68 1.68 150 A-Waking itcssurc R,dingi arc for rohvasce only and bored en Sdi.40 pipe.Fur ER IMO MARC, and FM pranwc runnels veriin pipe schodule,plaasa visit amtilin&com cc contact your local Anvil lApresenMirre. STRAIGHT TEE '`z iINVI (KF/r vv4�� Ductile Iron c--- . MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL & ULC Listed & FM Approved for 500 psi service. f Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE.Ductile iron fittings hove higher tensile strength than that of stool pipe.Tlsendlore,twee tigbfaming con case damage to pipe rlsreods w4sich may cause leakage.Dtxiile iron fittings should be tightened three turns beyond bond tight,but no more kin lour tans, uesa �rrrtavt:o STRAIGHT TEE Fa vorooa'rosowa�ennl. maa. or voodoo a wrowaor011 com re Meta. Nominal Site Mex.Working Dimensions Approx. Pressure. A g Wt.Foch frt.oorn) P5(Vol In.Mimi M.F myr fie (ig! �'®l ,._. 500 1.50 1.50 0.85 B 3BJ9 P`. l i 500 1.75 1.75 1.22 '"" r t4.aS 44.45 05.`: 1.', 500 1.94 1.94 1.55 <b5P 4927 4927 ari �- A ►,--A�� 2 500 2.25 2.25 2.45 4 3450 51.iS 51 is i! A-Working Pressure Railings aro for refven=only and bowl on Sch.IO pipe.For fat loot UVULC, rani FM prestiwe rulings versus pipe schedule,please visit arm'lintl.carn or conlaci yaw local Anvil RepreseMOInt BUSHINGS ("Jr-A. luviL CCCC /FINvi Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL&ULC Listed & 4' _ FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME B1,20,1. `` NOTICE;Ductile Iran fillings ha.e higher knsrle strength than that of steel pipe.Therefore,ores tightening can nest danxge to pipe Goods while may cause kwkage.Ductile iron fieings should be tightened three turns beyond tend light,let no more them lour hens. a®r Q ttnb APPROVE° BUSHINGS r�v>ow r*x ,.=re,«a .sa...cwMa a u»uen an MF S.nW n(V+uaruerF. Nanino4 Siva Max.Working Dimensions Style Approx. Pressure. A 8 ( Wt.Each M.foot) PS1 Ms) m.WA) 1r rA7al) an.f tbs,f+g) C-I f I ic' 500 035 0.25 1,42 Outside 0.22 B .7 V0. 5 1.42 .17N 1 x 500 0.75 015 1 d2 Outside 0.17 A 19t5 5..35 0.a5 1u x 1 500 0.80 0.28 1.76 Wade 0.28 Inside Head ' i3]:+ 2052 2 11 0,i3 1 irx 1 500 0.83 0.31 2.00 outside 0.45 45, 5455 2i LL` i.874 N.x 1 1 SOO 083 0,31 2.00 Outside 0.30 C 1 4 4f,a.. .3" 2LC5 f.U4 11111111111•111111 B 2 x 1 500 0_$8 OM 1.95 Inhale 0.67 A 5° :.11.7 22.3 u 4 i4 0.5? e 3C; 2 x 1'J, 500 0.88 0,34 2.48 Outside 0.73 {sd.fit .. 2.35 8.(5e .;a 0;3 Outside Head 2 x 11/2 500 0.88 0,34 2.48 Outside 0.61 ♦-Working Pressure t re ngs are hor reference ady and based on ScA.40 pipe.For the Indust Ut/ULC, and f M primers rotings*entos pipe schedule,phase visa orreginticorn or twihnt your local Anvil Rapresmtolise. CAR :, will (CCS----PF/FINV Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL & ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65,45-12. Dimensions conform to ASME B 16.14 Threads ore NPT per ANSI/ASME B1.20.1. NOTICE:Ductile iron finings hove higher'ensile strength than that of steel pipe.Tlreselme,over tightening tan<owe damage to pipe lxeodt which may cause leakage.Ductile iron lt1ngs should be lightened three turns beyond hand Kg1.t,but no not than lour hums. eC)le 41> auto APPRDYee CAP ra Larr9vlpoc,fsi NW,art Lmrnsm. Nay err WebrteMIWYMIM140,8 COT IX asxwt VI!nor 5drra Rt(raaararn.ra Nominal Size Max.Working Dimensions Approx. Pressures d WI.Each AT(on) PS)OW t(ore o) ibx(ie)� 1 500 1.16 0.32 A 500 1.78 0.43 ; . : _. pa50 0..7o 1 ; 500 1.33 0.60 3450 ?; 2 500 1.45 0.91 3450 a t' A—Working Pressure Ra ngs am for refererco only and based on Sch,AD pipe,For des brow UVULC, and FM pressure roadrtgs versus pipe schedule,please visit am+9ind.wm a conlad your local Anvil P.eprese.ninhive. COUPLING z 1111IVIL Ductile Iron a.� MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UI.& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B 16.14 Threads are NPT per ANSI/ASME 81.20.1. NOTICE:Ductile iron fillings have higher tensile strength than that of stet pipe.Therefore,over tightening con copse damage to pipe!tweak.which may cause leakage.Ductile iron finings should be lightened three turns beyond bond ngbt,but no mare than lour toms. C® LIM APPROVED ussrevAinraft.totrio$and Umtata," COUPLING rp at we*Amara„corn woad en Me sat rtrrnssresrv.s Nominal Size Max.Working Dimetnions Approx. PressareA A WI.Each 7n Cann] ASf fire) At.firm) Iles.as) r"—C�) 1 500 1.67 0,40 1% 500 1.43 0.57 -- ,y3 Z5 f z 500 7.15 0.75 c50 i d.34 7 500 7.53 1.15 ..»d= 642e 05? A-Working Pressure Ratings ors For refrenca orrly and based on Sch.40 pipe.For die bless UWtC, and FM prossure ratings versus pipe schedule,please visit ansallntl.aorn ce eau,hut your loco)Anvil Represcnwtive. CROSS wIL <� /Fw% Ductile Iron MATERIAL SPECIFICATIONS a, r Ductile iron Ihreaded Fittings are UL& ULC Listed & ,, � FM Approved for 500 psi service. ` ii Ductile iron per ASTM A536 Class 65-45-12. Ir''i d , Dimensions conform to ASME B16.3 F Threads are NPT per ANSI/ASME B 1.20.1. `- ,-_,,gP; NOTICE:Ductile iron fillings hove higher'ensile strength than that of steel ,. .. pipe.The eface,over lightening con curse domoge to pipe threads which may cause leakage.Ductile iron fittings should he tightened three turns beyond bond tight,but no more than lair turns. CC)K LI1® APPROVER CROSSFa usbgs�lvpw De vus and lanrewV n. tisa w*Alma at*a*.anlwM man a eraan an lent salon fAWa.Amur.. Nominal Site Max.Working .._ Dimensions Approx. Pressured d B WI.Each in.(m ) 610it7 ). (aenJ kx( lbs.(kg) 1 SOO 155 1.50 0.98 1 � � _ , i .5, 14—B B t:�a 500 1.75 L75 1.54 ' 4d4`. ,',' 0d3 1 500 1.94 1.94 1.90 �.•• a .56 #977 O d.at ' t 2 SOO 2.25 2.25 2.95 j4 - x -r 345 57.i5 1;ixi 500 1.58 1.67 1.27 A 37a75 3450 40.i3 03a 4 1:4 x 1 500 1.65 1.80 1.48 45a25 3455 ;4'I 0i. 2 x 1 500 1.73 2.02 2.10 55<75 345' ;10 Li 95 y-Working Pressure Ratings are for reference o1if end baud au&I.40 pipe.For the latest UUUK, and FM pressure ratings lerstws pipe schedule,please visit otwalir tl.com or contact your local Moil Representative. REDUCING 90° ELBOW ("r A!!!v! (( F/awvl Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed & FM Approved for 500 psi service. i, Ductile iron per ASTM A536 Class 65-45-12. r Dimensions conform to ASME B16,3 'Threads ore NM-per ANSI/ASME 131.20.1. ....-- NOTICE:Ductile iron fittings hare higher tensile strength than that of steel pipe.Thererore,Dyer tightening ton cause damage la pipe itteads which may come leakage.Ductile iron fillings should be tightened three turns beyond hand tight,but no more than bur turns. e®rt tattle APPROVED Daltni,and REDUCING 90° ELBOW Ctesir nnN a'a!KRnlY#1oomtt [YA14KY en NW S.lbt{{B�(liOINlM4 Nominal Sin Max.Working Dimensions Approx. Pressure. A 8 Wt.Foch lit.feral PSI fkPe/ In.(arnl M.(aa90 fin:t'kg) 1 x .. 500 1.26 1.36 0.44 1 x 1'+ 500 1.37 1.45 0.52 B-'I .1,7i .NNero 34.29 1..24 , �`i 1Ytx% 500 1.34 1,53 0.64 tl 3Z'x i; i4350 34.03 1.7.79 -{- ,•', - 11,a V, 500 1.45 1.62 0.72 A 32r26 345E 4L14 0.33 till x 1 500 1.58 1.67 0.75 32x25 3450 40.13 42.47 0.34 14i x 1 500 1.65 1.110 0.92 40r25 3450 41.91 43.77 042 1114 x l% 500 1.82 1. t 1.08 4,sv3� 3450 46.22 43.75 49 2 x . 500 1.49 1,t t 1.08 3453 31..84 4) f 54a 2 x 500 1.6E 1.97 1.24 345E 40:64 ^G'cv s 2 x 1 500 1.73 2.02 1.40 5125 345E 4394 130 064' 2 x 1 h 500 1.90 2.10 1.52 50.r 3: 345E 0 l0 2 x 115 500 2.02 2.16 1.65 50x46 3455 5': 0't AL-Worland Pressure Ratings ore for relererste Yady and based on Sch.40 pipe.For ihe latest UUULC, oed FM pressure ratings versus pipe schedule,pleau visit amAind.core or cooled your loco)Amil Represses/p ive. REDUCING COUPLING (ACC SPF/ANv Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B 16.3 ts* Threads ore NPT per ANSI/ASME B 1.20,1. NOTICE:Ductile iron finings have higher tensile strength than that of steel pipe.Therefore,over tightening con come damage to pipe threads which may cause leakage.Ductile iron fittings should be tightened three turns beyond hand tight,but no more than lour tams. C©K 1161e11 MPROWo REDUCING COUPLING c4u g, rrkt�"�Jcrnor NYrg tpWoif t*at and L[r}eO LG`W.`t an A'rvd SAW M{.rasomIIM Nominal Size Max.Working Dimensions Approx. Pressure. R WI.Each kL Gum) PSI(kJ ) M.Om) tbs.(kp l x 500 1.69 0.39 A 1 x st 500 1.69 0.53 v2 74 -Working Pressure Ratings ore tor rekvence only and hosed on Sch.d0 pipe.For the latest UIJUIC, and FM pressure ratings versus pipe schedvle,phase visit orw4lintcore or contort your beat Anvil Ropreserrolinr. REDUCING TEE z IL sPF/ Ductile Iron MATERIAL SPECIFICATIONS f Ductile iron threaded fittings ore UL& ULC Listed & C FM Approved for 500 psi service. Y r - Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME B16.3 A- 4 -B- Threads ore NPT per ANSI/ASME B 1.20.1. REDUCING TEE NOTICE Ductile iron sings hwe higher ternile strersglh Own shot of steel pipe.The:etore,over KgIiening con toot&Image so pipe tueods which Max. Dimensions Approx. may Corse leolwge.Ductile Iron finings should be tightened three turns NominalCalc, p Sire Working Wlro . beyond bond right,but no."tiro t,o+lwr rums, Pressure• A B oar ,.401,1,I NOW ✓,.lm0 it(mid h fmmd tbx fkpd LISTS APPROVED I x .x 1 500 1.50 1.36 1.50 0.64 rot bMMo.Aer-'•^a(moor a Ur�nt4-9 yrrA qy y pyj8,[wens Jn.MAU inn tt ,s l:� centh'f On M.a S.+Mx R44.0-a Msno, l x l;x l 500 1.50 1.45 1.50 0,73 ' • 0 r ' x wo i x 1 1.26 1.26 1.36 0,71 REDUCING TEE -IX-1 145 76 Max. Dimensions Approx. Sox_l x 1 x 500 13T 1 37 n F, 0,34 Nominal Size Walking A prox. _n och 1 x 1 x ki 500 1.67 1.67 I S8 08 Pressure* A 8 C 42.4) 0 e4 ..... I - 1 x I x 1 ., 500 1.80 1.80 1.65 1.16 M.Umn1 PSt tks) iA..may lr.from) Its.i ei 1;;x 1 x.', 500 1s34 1.26r 1.53 , 1 :x l'r x I; 507 152 1.15 1 24 0.82 3?�02 ' ''' l'hx16x1 500 165 180 1.30 - 'PA x 1 x';i 500 1.45 1.37 1.62 0.90 ,,,4t ,2?. 3450 1»x d x 1 500 1.58 Li0 1.67 11.00 1'h x 1/x 114 SO0 1.82 1.85 1.48 +x4 ,32 34.,p l'/,x l x l5 500 1.75 67 1.75 1,08 10116 x 2 500 2.16 2.02 1.98 a 1, 44 2x1x2 500 202 225 2-15 1V,xlx1'h 500 1.88 1.80 1.80 1.82 142 .,_:?Xr50 _ 34}Il 32x25r4n 9450 " '' 4t122 ''r_ 2x1V.x2 500 2.10 2.25 2.30 11&xI1 x'h 500 1.34 134 1_53 0.86 1,0,3115 ,71�0 1?4 34 1 1. i 15 32x+2x 3-*r, :,Fr 0 1V',x114x4'i 5O0 145 145 162 092 Al 4e1.15 94.s 37 e 41./ 3i,32120 3436 x 4rix� Tt't 61 IS2 1_62 1riix116x1 500 1.58 1.58 1.67 0.95 32x40x70 3450 4064 ", 32x322125 3455 '"" 2x11/2x1 500 1.73 1.65 2.02 1.64 116x11/4x1114 SOO I.BE 1.88 1.87 1.4S +=x40x25 3451 4394 .. 32x22140 3455 2x1'hx1V, 500 1.90 1.87 2.10 . 1.80 1/x1144x2 500 2.19 2,10 1.90 1.75 f.'.1 r40x+2 3,1:, dt',t 32x31x5 34a3 2 '" 2x1'hx114 500 202 194 216 . 2.00 1Yrxlxli 500 1.41 1.34 1.66 0,95 S;x40xdu 4'1 x 2'5 x 15 5459 `�'i 5 ' .` 2 x 1'R x 2 500 2.25 2.16 2,25 2.35 l xlx84 500 1.52 1.37 1.75 1.14 0x40x5c 3450 57;5 ,,4Iv 49 x 22 x 20 J4 rr 44 4i` 2 d e li 500 149 ' 1.49 1.88 160 11/2x1x1 145 150 1.80 1.17 56,50+6 345C s74ri 37r5 , a77i 47xr5r23 a45Cr d1.s' ' ?t 2x2x'Y 500 1.60 1.60 1.97 168 l'h x 1 x 1% 500 182 1.67 1.88 1.34 5,,,50 x 71:1 34S 43 44 , 40 64 0 Ji 40r.5152 3458 4.623 4e4" 2x1x1 1.73 1.73 2.02 1.85 14 x l x 1'h 500 1.94 1.80 1.94 145 ,i,x CC,29. 3450 43 52 43 94 :;54 10A75x4a 345C: 49.2t' 45,':'' 2x2x1'% 500 ' 1.90 , 1.90 2.10 . 2.04 11iixlux4 500 1.41 1.34 1.66 1.05 3,5,5px;; 3,sc 4445 40x32z15 3457 3581 34.04 2x2x116 500 202 202 216 2_18 11fxl1Gx1', 500 1.52 1.45 1.75 1.15 s'x5%1,+46 3e3Li 2' 4,'42 '9-' 40x3?x20 345$ 38,51 ,tu_t3 44,45 i5` 2x2x2'h 500 2.60 2.60 2.39 3.61 14x1 ,x1 500 1.65 1.58 1.80 1.25 3 ,5t+rE3 s'i 4?42 ;4 4r: - ,r0 41.9) 40L2 45'2 t952 . 2,y _ Rangy r^toy �slr 2.28 2sfx2xY, 500 174 1.b0 2.32 Ph,x1.,x2 500 2.16 2.10 2. 2 1.90 . , 'r', 24+n . 4r; a,'C, �4. r. S3 51.30 p 1'l:x 1°ry x i 500 1.4 1.41 1.16 1. 5 `"°`I ng Pressure s°�°I°" °e" °"d based°n sxh s0 pica car t� lalni ULAK,oral FM pressure roetngs*"Arson pipe xbod� ,please owitrol con or 'Rill 23.8 35.Pi 2946 0.52 minx your local Amil Represematiive. FireLock® Rigid C ® FM �c yis LPCB eero;zso con page a S Approved, SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 005 WITH VIC-PLUST'"GASKET SYSTEM (NORTH AMERICA ONLY) FireLock Style 005 rigid coupling has a unique, patented angle-pad design which allows the housings to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is obtained. Support and hanging requirements correspond to NFPA 13 Sprinkler Systems.Angle-pad design permits assembly by removing one nut/bolt and swinging the housing over the gasket.This PATENTED reduces components to handle during assembly. Style 005 FireLock coupling are designed and recommended for use ONLY on fire ViCpr/!/S Gasket System protection systems. Vic-PlusT"'Gasket System: In North America,Victaulic offers a gasket system which requires no field lubrication on wet I11 �I pipe systems that are hydrostatically tested.The Vic-Plus System (patented)is dry,clean,and non-toxic. It reduces assembly time substantially and eliminates the mess and chance of over- I lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook(I-100)for 1111111 supplemental lubrication requirements and dry pipe fire protection system notes. Exaggerated for clarity LISTING/APPROVALS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Related Working Pressure-psi Related Working Pressure- psi Relaled Working Pressure-psi Pipe Site Pipe Size Pipe Size Sch. Inches UL ULC FM Sch. Inches UL ULC FM Sch. Inches UL ULC FM 5 1 1/4-3 175 175 • '75 EL 1P54-2 300 N/A N/A MT 1 l4—2 300 N/A N/A 11/4-4 350 350 350 ET 115-2 300 N/A N/A STF 1,<-4 N/A N/A 300 10,40 5-8 300 • 300 300 F7 r-6 3008 N/A 300 Steady 1 V4 2', N/A N/A 300 BLT 114—2 300 300 N/A FF 1!h-4 N/A N/A 300 TO 3-8 • N/A N/A 300 DF 1'/4-3 300 300 300 GAL-71Y4-2 300 N/A N/A VvLS 18-2'. 300 300 N/A DT 11/4-2 300 300 N/A MLT 1'/4-2 300 N/A N/A XL 11/4-3 300 300 300 EF 1'V-4 175@ N/A 175 OAT 1/4-4 300 N/A 300° *FM approved for service in 11/4-4"pipe. k UL Listed for service up to 4'pipe only. @ UL Listed for service up to 3"only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IC.taulIL' REV J IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Co .upiin STYLE 005 WITH VIC-PLUS"'GASKET SYSTEM(NORTH AMERICA ONLY) DIMENSIONS Max.Work Max.End Allow.Pipe BoItlNu1@ Approx. see Pressure§* Load* End Sep.t No-Size Dimensions-Inches/mm Wgt.Each _ Y -Z-a Actual IIC�II Nominal Outside [yjL�ATM ' Pl. l See Diameter PSI Lbs. Inches Inches Lbs. kit x-� 7 Inches/rum 1660 Inches/met kPa"CI N nun S 005 %m g Y Z kg 2-%ax2/ 20 114 1.88 1.5 �l �I( I- 42 42.4 2413 3370 1.2 70 114 48 0.5 -/ " IJ Y 1/ 1.900 350 990 0.05 2-i/e x 2'/1 100 4.75 1.88 1.2 40 483 2413 4415 1.2 76 121 48 0.5 Rated for wet and dry sprinkler systems at 2 2.375 350 1550 0.07 2-3x 2,h' 3.50 5.25 - 1.88 1.6 350 ps1/2413kPa for 1 14-4'732-100mm 50 60.3 2413 6900 17 89 133 . 48 0.7 sizes and 300 psi/2068kPa for 4%.-87108 26 2.875 350 2270 0.07 400 5.75 188 19 -200mm sizes;Schedule 10 roll grooved or 65 73.0 2413 10110 1.7 2-1/42 21/2 102 146 48 09 Schedule 40 cut or roll grooved steel pipe. 3.000 350 2475 0.07 413 575 1.88 1.9 Style 005 Is rigid and does not accommodate 76.1 mm 76.1 2413 11010 1.7 2-4 x 2'h 105 146 48 0.9 expansion,contraction or angular deflection. - -- -- -- 3 3.500 350 3365 0.07 2-3/2221/2 463 6.13 1.88 2.1 80 88.9 2413 - 14985 1.7 118 156 48 1.0 4 4.500 350 5565 0.16 2-Yax 2h 575 7.25 2.'3 3.1 100 114.3 2413 24770 4.1 146 184 54 1.4 4250 300 - 4255 0.16 2-'hx2Yz 5.63 7.25 2.13 3.1 108.0mm 108.0 2068 18940 4.1 143 184 54 1.4 5 5.563 300 7290 0.16 6.88 900 2.13 4.5 125 14'._3 2068 32445 4.1 - 2-'h x 3 175 229 54 2.0 133,Ornm 5.250 300 6493 0.16 2-'hx2sk 663 900 2.13 4.5 ".33.0 2068 28900 4.1 168 729 54 ZO 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 1397mm, 139.7 2068 31715 4.1 2-'.4 2294 175 229 54 2.2 6 6.625 300 1034C 0.16 800 10.00 - 2.13 5.0 150 168.3 2068 46020 4.1 2 1/2 x 3 203 254 53 2.3 6.250 300 9200 0.16 - 7,63 10.00 2.13 5.5 - 159.0mm 159.0 2068 40955 4.1 2-'h x 23a' 194 254 54 2.5 6500 300 9955 0.16 8.15 1000 2.13 5.5 165.1 mm 165 1 2068 44295 4.1 2-'L x 3 207 254 54 2.5 8 8.625 300 17525 0.19 2 'hx4'k 1050 314 2.63 11.3 200 2"91 2068 78000 4.8 267 334 67 5.1 - ' Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI) steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for perfor- mance on other pipe. WARNING:FOR ONE TIME FIELDTFST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only.Style 005 couplings are con- sidered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments.Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. § Style 005 couplings are VdS and LPC Approved to 12 Bar/175 psi. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt'dUlIC` 10.02-2 • IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 10.02 FireLock® Rigid Coupling STYLE 005 WITH VIC-PLUS"GASKET SYSTEM (NORTH AMERICA ONLY) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating:Orange enamel(North America); red enamel(Europe) • Optional: Hot dipped galvanized Gasket: • Grade"E"EPDM—Type A Vic-Plus'"Gasket System A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade"E"Type A Vic-Plus'"Gasket System, requiring no field lubrication for most installation conditions. • Grade"L"Silicone Recommended for dry heat,air without hydrocarbons to+350°F and certain chemical services. For dry services,Victaulic continues to recommend the use of Grade"E"Type A FlushSeal®Gasket. Contact Victaulic for details. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. A Standard gasket and FlushSeal gasket approved for dry pipe systems to—40°F/-40°C. Based on "typical" pipe surface conditions,supplemental lubricant is recommended for services installed below 0°F/-18°C and for all dry pipe systems or systems to be subjected to air tests prior to being filled with water.Supplemental lubrication may also be required on pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams.Victaulic continues to recommend the use of FlushSeal gaskets for dry services. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. .CtauliC` REV) rFir.::�1 :� \\ ' ill I . eL_ook® Rigid Coupling STYLE 005 WITH VIC-PLUST"'GASKET SYSTEM (NORTH AMERICA ONLY) GENERAL NOTES WARNING: Depressurize and drain the piping system before attempting to install, remove,or adjust any Victaulic piping products. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. For complete contact information,visit www.victaulic.com 10.02 1538 REV 1 UPDATED 3/2011 IRtaulIC. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2011 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.02 • • - • II It ligNIIIMIN . ... OL FM ® V`S I(Ill rraYl --,. FireLock® Ou k . l J SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating/,3,and 1"/15, 20 and 25mm outlets for directly connecting sprinklers,drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/through 76.1 mm/32 to 76.1mm piping systems, Style 922 outlets are UL/ULC Listed, LPC,Vds/FM approved for branch connections on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly 1: compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* It is supplied with a clear, rust inhibitive coating.Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Gasket: • Grade"E" EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical require- ments of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER • CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. OtaUlIC DCU fl 1/l CO 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS I U.JL - FireLock® Outlet-T FM 0 ds t rFc SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 V 1 DIMENSIONS Nominal Size Hole Approx. inr:hes/mm Diameter Dimensions-inches/millimeters Weight Each -Run X Branch +0.06/+1.5 I Y -Z-{ FPTf. -0.00/-0.0 T' V W Y Z Ihs/kg 1 '1.1 'Y2 11Ae 1.30 1 83 110 3.87 256 1.0 V'r■ .,l 1 , 30.2 33.0 46.5 27.9 98.3 65.0 0.45 2 T 15 I �^� T 7 114o 1.28 183 110 3.87 256 11 . . . 1. 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 r., �. VV i./ 1 I 13/16 1.52 2.18 1.10 3.87 2.56 1.2 IVI 25 30.2 38.6 55,4 27.9 98.3 65.0 0.54 1'/2 1 1 3636 1.42 195 122 4.08 2.56 1 2 40 X 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3i5 13/te 1.40 1.95 1.22 4.08 2.56 1 1 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2.30 122 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 1/21 Ste 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 I 116.8 65.0 0.59 334 1 Ye 1.64 2.19 1 46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 I Sle 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 371 116.8 65.0 0.68 - 21/2 v2 1Ye 1.91 7.44 171 5.40 2.56 1.6 65 X 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 34 11'6 1.89 2.44 1 71 5.40 2.56 16 20 30.2 480 62.0 43.4 137.2 65.0 0.73 1 13/e 2.13 2.79 1.71 5.40 2.56 16 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 1/2 13/i c 1 91 2.44 1.71 5.5 0 2.56 16 76.1 mm'. X 15 30.2 485 62.0 43.4 139.7 65.0 0.73 3/a 13/6 111.89 2.44 1.71 1 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 1 139.7 65.0 0.73 13/6 2.13 2.79 171 5.50 2.56 1.7 25 30.2 , 54.1 70.9 43 4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. IICtaUlIIC` 1h C9 .1 DC II n IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS I U.0 Z - FireLock® Outlet-T FM ® (Vds) Wu SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 PERFORMANCE Equivalent Length of Nominal Size 1"Pipe *,,,:.; itlell.::.. Feet/meters 11 1 85 25 2.6 1 8.5 25 2.6 2 8.5 50 _ ,C _ _ 2.6 2%2 R 85 65 2.6 76.1 mm X I 8.5 25 2.6 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.ID 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE I ISA iGta U 11('. DCA/ fl t'. 1.1 Z uL FM ® (Vtls) vifx SEE VICTAULIC PUBLICATION 10.01 FDR DETAILS STYLE 922 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • US&WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905-884-7444 1-610-559-3300 Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax) 4901 Kesslersville Road viccanada@victaulic.com vical©victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38(fax) 86-21-54253671 (fax) 1-610-250-8817 (fax) viceuro@victaulic.be vicap@victaulic.com piskvic@victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 111111111111111111111111111111111111111144(0) 1438741100 971-4-883-88-70 44(0) 1438313883(fax) 971-4-883-88-60(fax) WCAS-6QKGYH viceuro@victaulic.be UPDATED 8/2006 10.52 3355 REV D ,ctau'1�. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2006 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA. in c9 DEL PORT A D,70R 97224e PHONE 503-620-4020 FIRE, I tV C■ FAX CCB# 641674 1058 Hangers FIRE PROTECTION CONTRACTORS PIPE RINGS (N)ANVIL.: • Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range:1/2"through 8" Material:Carbon steel Finish:0 Galvanized Service:Recommended for suspension of non-insulated stationary pipe line. -- Maximum Temperature:650°F Approvals:Complies with Federal Specification A-A-1192A(Type 10) WW-H-171-E(Type 10),ANSI/MSS SP-69 and MSS SP-58(Type 10). UL Listed and FM Approved(Sizes 3/4"-8"). Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2"through 6"sizes.The capture is permanent in the bottom portion of the band,allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering:Specify size,figure number and name. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. Metric nut available upon request.Non-captured nut also available upon request. -1.- 'q wq F T\ IfF 1a C _ / 1 _, 1 V4"through 8"pipe 1/2"through 1"pipe FIG. 69: LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Size Max Load Weight Rod Size A B C F h 0.10 2% 2 19/6 3V4 0.10 23/4 1% 15/6 1 0.10 29/16 11%6 1 1 Y 300 0.10 2% 1' 7/6 1 Y 0.10 3 2% 1% 2 0.11 31/4 2% 1% 2% 0.20 4 2% 15/6 3 525 0.20 313A6 215/s 1%s 4 650 0.30 411/s 313/1s 5 0.54 5%6 4% 19/,s 6 1,000 0.65 1/s _ 61%6 53/6 2% 8 1.00 8 7 211/6 Note:Reflects changes in rod diameter from previously published data per recent revisions in MSS-SP-58&69 PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved - Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog PH-2008 HANGER RODS 10)ANVI Fig. 146 Continuous Threaded Rod Size Range:'/4'through 1 '/2"Stocked in six,ten,and twelve foot lengths.Other even foot lengths can be furnished to order. Material:Carbon steel;rod threaded complete length. Finish:❑ Plain or❑galvanized. 11111111111111111111111111111. Maximum Temperature:650°F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. [a Length LIMMMMM111111M11MMMMMMMMIIMMMHIIIKSOMMMM1111MSu111IIM0MM11MMMM1MI1MM1M1SIMMMU1MM11MMMMMM11M11MMMS M11MMMNNI A FIG. 146: LOADS(LBS) •WEIGHTS (LBS) DIMENSIONS(IN) Rod Size Threads Max Load Weight A per Inch 650° F per Ft. 1/4 20 240 0.12 16 730 0.30 1/2 13 1,350 0.53 5/a 11 2,160 0.84 3/4 10 3,230 1.20 9 4,480 1.70 1 8 5,900 2.30 11/4 7 9,500 3.60 11/2 6 13,800 5.10 Note:Other rod sizes available upon request.Class 2 fit is available upon request. PROJECT INFORMATION APPROVAL STAMP Project: ❑Approved . Address: ❑Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: Catalog PH-2008 • csr flood SAMMYS ""it WOOD •1/4"Rod• Vertical Mount B01 quantity 100 except as noted with this marking 1♦) Use S14 Nut Driver(Item s100) • Bos quuntity 50 Item # Model Rod Size Shk Dia Shk Lgth 20 GST.750 1/4-20 1/4 3/4 at4 them ahKn 21 GST 100 1/4-20 1/4 1 22 GST 200 1/4-20 1/4 2 23 GST 300 1/4-20 1/4 3 24• GST 600 1/4-20 1/4 6 See page 13 for Stainless Steel WOOD•3/8"Rod•Vertical Mount Note:Screws less than 2^in Use#14 Nut Driver(Item#t100) length will be plated yellow. Greater than 2"are clear FM Test UL Test UURN zinc per ASTMB63311I Item# Model Rod Size Shk Dia Shk Lgth Load,lb. Load,lb. Pipe Size Actual Pullout 10 GST.75 316.16 1/4 3/4 564#-6 Fly 11 GST 10 3/8-16 1/4 1 210#-7/16 USB /� 670#-3/4"Ply <f,*'`®" 12 GST 20 3/8-16 1/4 2 940# 850# 3/4-21/2 1760#-Fr e14 them.io,, 11y 27 • GST 25-380 3/8-16 3/8 2 1/2 1500# 4 2113#-Fr 44, 13 GST 30 3/8-16 1/4 3 1475# 1500# 3/4-4 2060#-Fr 403• GST 40 3/8-16 1/4 4 2180#-Fr 14 • GST 60 3/8-16 1/4 6 2230#-Fr WOOD • 1/2"Rod• Vertical Mount Use#14SWNut Driver(Item S101) 4414 Item # Model Rod Size Shk Dia Shk Lgth Actual Pullout 8 • GST 2 1/2-13 1/4 2 1760#-Fir aiavw them pl011 06• GST 2.5-381 1/2-13 3/8 2 1/2 2113#-Fr vat,rhr ausW exert be arre for trrcwr with 1/1"rap 15• GST 3 1/2-13 1/4 3 2275#-Fr _ 16• GST 4 1/2-13 1/4 4 2180#-Fir 17• GST 6 1/2-13 1/4 6 2230#-Fr Installations Not leas than 2-nominal width ee Page S for installation instructions. < 1i ia"l > (l n ,l Installation f A per NFPA 13 ` s] y .....Sammy i 1: me 6 s°""Y `" 1 TGI Joist/Truss e Consult trues manufacturer for recommended Inatallellon point. Wood Flooring $See"Special Notes' .... on"caner i'7 Sammy« 1 _ _ a-a Wood Joist Lower face off a- ---r Sammy beam or total sue• • Minimum 2"imbedment Into base material for NFPA 13 compliance For vortical use. AIN t p Install in center - e '-a Sammy of tower face. Double Sheetrock Calling .! 1t you don't see lt,call us at ! I 1.888.773.0001 Wood-Sammys Note:Must be installed with appropriate nut driver to comply with warranty. SWG flood 40, to- See page 13 for Stainless Steel SIDEWINDERS WOOD•1/4"Rod•Horizontal Mount Rat qunnlif, 10(1 except as noted with Mir marking ,., • Use#14SW Nut Driver(Item#101) • Rns quantity 50 Item # Model Rod Size Shk Gia Shk Lgth Actual Shear/Pullout ,,,`11 „i„„ 300 SWG 200 1/4-20 1/4 2 1725#-Fr Note:Screws less than 2'.in length WOOD •3/8"Rod•Horizontal Mount will be plated yellow.Greater than Use#14SW Nut Driver(Item#101) 2"are clear zinc per ASTb1RG33111 UL Test UL Pipe Actual Item # Model Rod Size Shk Dia Shk Lgth Load,lb. Size Shear/Pullout 18 SWG 10 3/8-16 1/4 1 af45st diem alai, Ik 19 SWG 20 3/8-16 1/4 2 1250# 3 1725#- Fr 26♦ SWG 25.380 3/8-16 3/8 2 1/2 1500# 4 2249#-Fir 25♦ SWG 30 3/8-16 1/4 3 a fastening through gusset plates.use the SWO 20(see page 5) Installations TGI Joist/Truss Consult truss manufacturer for _$ recommended installation point Sidewinder a+ (See'Special Notes" Floor Joist w on''poor r1 Sidewinder 15 jAll MAN ury WOOD INSTALLATION INSTRUCTIONS GST&SWG—See diagram figures 1-4,11-14 on page 1 1 18 and 19. Not less than 2"nominal width 11 12-1 (Self drilling& self-lapping into wood) up to 3 12"pipe:not less than 3" nominal width 4"d 5"pipe Step 1: Insert the appropriate nut driver into a 3/8"or 1/2" portable drill: (a) Use#14 for GST for 3/8"and 1/4"rod: (b) Installation f use#14SW for SWG, and for GST for 1/2" rod. per NPPA 13 r Step 2: Insert the screw into the nut driver. Now you are ready to install the screw. Step 3: Position drill and begin installation: (a) for installing GST drill should be in a vertical position; (b)for installing SWG drill should be in a horizontal position at a right angle �E�-- sidcwiMer to the structural member. Minimum 212"from bottom tar branch lines.Minimum 3"from Step 4: When the nut driver spins freely on the cap of the bottom for main lines.Exception: This requirement shall not apply to 2" screw installation is complete. or thicker nailing slnpa nesting on lop of steel beams. • OW, Step 5: Screw is now ready to receive 1/4", 3/8", 1/2"or V metric all thread rod or bolt stock. Eye protection should be worn at all times when install- I I ing this product. Note:Masi be installed with appropriate nut driver to comply with warranty, Wood-Sidewinders 5 2 • D��• PORTLA D,7OR 97224e FIRE PHONE 0- IN FAX 503-620-1-620-1058 ' M CCB# 64174 S • rinkler ea s FIRE PROTECTION CONTRACTORS Bulletin 014 Rev. F co MI ®. Reliable Model Fl FR56 Series c Quick Response Standard SprayDO Model Fl FR56 Sprinkler Types Standard Upright �, Standard Pendent Conventional a !a I Vertical Sidewall Horizontal Sidewall " ' e Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall T Model Fl FR56 Concealed Sprinkler Types Standard Pendent011 , Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category `"�" _ Sprinklers,Automatic&Open(VNIV) :;,?; ( _ t Quick Response Sprinkler ( `� , ua Product Description �. Reliable Models F1FR56 Series Sprinklers are quick re- "�` sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2 sprinkler, The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- � klers have demonstrated response times in laboratory tests r ! ` which are five to ten times faster than standard response / sprinklers. This quick response enables the Model F1FR56 /X Series sprinklers to apply water to a fire much faster than ,1,x -/ standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely manu- Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid Application in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands, forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec- uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lot to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as - specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler IdenSfication Number (SIN) Orifice Size Height Organization US Metric Upright Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position /2"(15mm) 1/2" NPT(RY) 5.6 80 2.25"(57mm) 1, 2,3,4 RA142501 RA1414(”(2) Conventional-Install in Upright or Pendent Position 15mm111 1/2" NPT(R4) 5.6 80 57mm 3,4 RA1475 1 cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. r a fo i Upright Pendent Conventional Model F1FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: - Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2" NPT(R1/2) 5.6 80 2.25"(57mm) RA1414 01 Refer to escutcheon data table for approvals and dimensions. f 2 5/8'D/4 (66.7mm] 2 I/4'HOLE DIA. HOLE IN CEILING [57mm] 1m OA -.A.2 5/76'DIA. [56.7mm) �— (49.269.2mm] /_CUP _ �_ --______ rr_=_I�==�, , r- —3, 1"x I/2"REONCER I I 1'X I/2"REDUCER TURN COLLAR 11 UNnL nowAGAINST SPRINKLER 1 WRENCH BOSS \ \ / / II IL _=_-� .I II =_I_ li \�—( J FACE CIF FIRING TO CEILING ' ,-- - ALUUSTMENT('I �� CEILING DIMENSION (I I I ��® .l = Ill FACE OF FITTING `I`i�IJJi ` ,� III III TO FACE OF CEILING !i III vmm �11 milli"; D7- roI� (3.2mmJ q,(» Ao 71iro 2 27/32'DL4. 014FGOI A0.IUSTMENT (22.Imm] -- 1 014FG02 . (I)REFER TO F1 Be F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (1)REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Nominal Sprinkler Approval Orifice Thread Size US Metric Height Organizations Identification Numbers (SIN) Y2"(15mm) 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485 15mm 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 40I ro LPC Approval is for pendent position only Sprinkler Type Deflector to Ceiling Distance vr>w0ey ', (Min. - Max.) Upright 4" (102mm)- 12"(305mm) 011 Pendent 4" (102mm)- 12"(305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers(SIN) Hazard h" (15mm) Y2"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435 FACE OF F/TT/NC(1) TO FACE OF CEILING DIMENSION 1 1/4'MIN. [31.8mm] 2 7/4"HOLE DIA. 1./2 "mm8J 4"-12" (572mm] [3 [101.6mm-304.8mmJ DE/L EC TO 1"X 1/2" REDUCER EFLCTOR /"" n1 I JO Imkx 1 75/16' D/A. /nnA li .4, [49.2mm] / RA -- ---- 2 27/32"DIA. xY { [72.2mm] IA�I Horizontal Sidewall TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. ADJUSTMENT(1) 073FG034 (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (2) FM APPROVED FOR 4" — 6"[101.5MM — 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers ' Installation Wrench: Model RC1 Sprinkler Wrench - Technical Data: Nominal "K"Factor , Thread Temp. Rating Max. Bulb Sprinkler Orifice US Metric Size Model Sprinkler Cover Ambient Color Approvals Identification Temp Number(SIN) h"(15mm) 5.6 80 1/2" NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1, 2,4L11 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1,2 RA1414 1/2"(15mm) 5.6 80 1/2" NPT F1FR 200°F/93°C 165°F/74°C 100F/38°C Green 1,2 RA1414 111 For VdS only= 155°F/68°C Norbulb and 1/2"[12,7mm]adjustment. I"x 1/2"REDUCING TEE OR ELBOW ____ 1"a, 7/2"REDUCING -!E I TEE OR ELBOW ll— — Hi 2 5/8"DIA. _ ILI 11.-_._..� 2 5/76" DIA — _ HOLE IN CEILING - G-'— 2 5/8"DIA. CUP `�_ .� 4 2 5/16"DIA — t HOLE IN CEILING III c�.. 1 1/2"MAX. CUP S 1 .� ' FACE OF FITTING I 111'' L71II 1 1/2"MAX. TO FACE OF CEILING - --- FACE OF FITTING_ T, DIMENSION i TO FACE OF CEILING CEILING rim i= 5i + — ••• • ly\ P i'" T;::::::' DIMENSION a^a.4 , ae� CEILING �i'p`i�m�� __._ 1/2" MAX. I 75/76" 5/16" MAX. N 3/4" COVER ADJUSTMENT COVER ADJUSTMENT COVER PLATE— 1 COVER PLATE— I ASSEMBLY -• 3 5/76"" DIA. ASSEMBLY 3 5/16" DIA. SPRINKLER / SPRINKLER / 1/2" ADJUSTMENT mwco. 5/16" ADJUSTMENT anrcoo - Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- Important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135°F Installation (57°C) or 165°F (74°C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as- as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover The Model F1FR56 Recessed Quick Response Sprin- plate assemblies provide either 1/2" (13mm)or 5/16" (8mm) klers are to be installed as shown.The Model F1 or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers. The use positive pressure in the space above. of any other recessed escutcheon will void all approvals After a 25/8" (67mm) diameter hole is cut in the ceil- and negate all warranties. ing, the sprinkler is easily installed with the Model RC1 When installing Model F1FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can inserting or removing the wrench from the sprinkler/cup be obtained with a torque of 8-18 ft-Ibs (10,8-24,4 N-m). assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHER PART torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed klers. onto the cup. Final adjustment is made by hand turning The Model F1 FR56/CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact Y2" orifice, 1/" NPT (R1/2), 135°F (57°C), 155°F (68°C), with the ceiling. Cover plate removal requires turning in - 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above. Conventional Concealed cover plate/cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate/cup assembly with the Model F1FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes CO THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes Sprinkler Escutcheon Cover plate time may leave the bulb vulnerable to damage. RASCO Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated(05) White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass(3) Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin 2 Max. Ambient Black Paint Black Paint Off White Classification Temperature Temp. Bulb Color Off White c2i Off White Black Paint °C °F Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100°F(38°C) Orange 01) Other finishes and colors are available on special order. Ordinary 68 155 100°F(38°C) Red Consult the factory for details. Intermediate 79 175 150°F(66°C) Yellow 2) cULus Listed only. Intermediate 93 200 150°F(66°C) Green (3) 200°F(93°C)maximum. High 0) 141 286 225°F(107°C) Blue (4) cULus listed"corrosion resistance"applies to SIN Numbers Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white. (5) FM Approvals finish as"Polyester coated"applies to SIN Number Escutcheon Data (1) RA1414(Pendent)in standard black or white. EscutcheonFace ofFiltmgto OrderingInformation Approvals Adjustment Ceiling or WallModel Dinension Dimension Specify: F1 1,3,4 MaxRPrass 11 "(38.1mm) hs"-'S/'" 1. Sprinkler Model Min Recess 3/4"(19.1mm) (5mm-24mm) 2. Sprinkler Type F2 1,2,3,4 Max Recess 1Y"(38.1mm) 3hs'-11hs' 3. Orifice Size Min Recess 1"(25mm) (5mm-17mm) FPPush-0N Max Recessed z/16"(11mm) 1/2" (38.1mm) 4. Deflector Type Thread-off 1'4 Min Recessed 13/4e(24mm) 1"(25.4mm) 5. Temperature Rating 0)SIN:RA1435-cULus and FM permits use with Fl or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9. Cover plate Model The Models F1FR56 and F1FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soap and water, ammonia or any other 13. Cover plate Finish cleaning. fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note:When Model F1FR56 Recessed sprinklers are ordered,the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- - ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. 5. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many ' precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices - • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gaugesldentification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. a Recycled Reliabld (800)82 -10488 2 Sales Offices Paper (800)848-6051 914)8 Sales Fax Corporate Offices Revision lines indicate updated or new data. 9-2042 www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 02/11 P/N 9999970300 F ex ea ' commercia ire span er connections YEARS OF EXCELLENCE IIMME11111111.11111 a Y V •� f+ dA ti:Yf� a.. jJ• milik -440 FLExHEAP • INDUSTRIES S u b m 1 tta The pioneers in flexible fire protection wwwflexhead.com Package -Ora OATEN COMPATIBLE APPROVED USTEO 41 N.Y.C. MEA #261-99-E CA: OPA-0672 i k FlexHead QUALITY FlexHead FFATUR ep • Best corrosion resistance ( Is seismically qualified for use, Made from 100°%° 304 stainless steel eliminating the need for an oversized Excellent friction loss values ring around the sprinkler head in One-inch true-bore ID reducing the need to ro seismic areas upsize mains and branch Lines • .; "., lit '°: Has the same product design that is Pressure surge protection „ • Fully braided connection improves pressure ; dual listed by both UL and FM capability and prevents hose damage ; : : Highest maximum working pressure e `' Can be produced domestically to Rated up to 300 psig meet all your project requirements • No o-rings or gaskets . -,. C Has serial identification with complete Welded connections reduce potential leak audit tracking of finished goods points at the inlet and outlet fitting :; , Tightest thread tolerances Has a comprehensive limited warranty • Outlet fitting threads are machined from f�' backed by an A++ insurance company solid bar stock reducing potential leaks at the sprinkler head fit-up zr ` Extra stability ,•. Bracket has a full 6 inch base to stabilize the sprinkler head during installation, pressurization or activation 40 .. .. � � ha Ym'1 41L Qi r� F Ot a. �4y y Mrd " It = FLEXHEAD .. , .„. it. '' e x CLISEU03 ®� INDUSTRIES srsro.coxvnre� APPROVED (,,I!, ,, �,°.. ., US.and international patents pending:,6,123,154,k6,119,784,#6,752,218,P7,032,680, The pioneers in flexible fire protection 116,488,097. ' + The FlezHead name and logo are trademarks of FlezHead Industries. 800-829-6975 www.flexhead.com -n.. ': FGG/BM/Ce"System Compatible indicates that this product has been tested,and is Cmonitored on art ongoing basis,ton assure its chemical compatibility with FlowGuard Gold®, $lazeMastere and Corzane pipe and fittings.FGG/BM/Cl",FlowGuard Golde,BlazeMasterw', and Conan'are licensed trademarks of The Lubrizol Corporation USGBC and LEED are registered trademarks of the U.S.Green Building Council. • - ' ` F ex ' ea ' commercia ire spnn er connections Index Installation Instructions 1 NFPA 13 Code Language and Seismic Qualification 3 Friction Loss Data and Specifications 5 Product Specification Sheets 7 FM Global: Testing & Approvals 9 FlexHead Products in Use 11 Loss Prevention Certification Board: Testing & Certifications 13 CA Office of Statewide Health Planning and Development 15 Other Approvals/Information 17 MEA Approval: NYC Department of Buildings 19 Limited Warranty 20 Whether your application is commercial, industrial, clean room, or institutional, FlexHead flexible sprinkler systems cart save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products. 4 F ex ' ea ' commercia ire spnn er connections Installation Instructions Tools Required `. . " Standard pipe wrench Safety glasses - Adjustable wrench Screwdriver Materials Required < sc ;k4y � ,: Sprinkler pipe thread sealant 2 Teflon' tape 1. Mounting Bracket Assembly 2. Attach Mounting Bracket M#: MP-24-BKT-2 to T-bar Suspended Ceiling Grid Remove one (1) 3/8" bolt and one (1) 1/4" bolt from hardware bag in box. Remove (1) universal hub and one Note: These products are designed for use with (1) mounting bracket from box. Thread the 3/8" bolt Intermediate or Heavy Duty ceiling grids manufactured through side of universal hub. Select one (1) of the four to ASTM C 635 (Standard Specification for the (4) sprinkler port locations on mounting bracket. Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in A. Insert tab of universal hub into slot on mounting Panel Ceilings) and ASTM C 636 (Standard Practice bracket as shown. (Photo la) for Installation of Metal Ceiling Suspension Systems B. Flip bracket over and insert and tighten 1/4" for Acoustical Tile and Lay-in Panels) Designation. attachment bolt thru pre-punched hole in bracket A. From above the ceiling, position FlexHead until tight as shown. (Photo 16) Mounting Bracket ends on to T-bar grid so that the center hole in support bracket aligns directly • above the sprinkler hole prepared in ceiling tile. Be sure the center section of the bracket end is 40 - on the outside of grid and base section is on the inside. Position the ends of the support 11111 ° bracket on the T-bar grid and push each of the " 111 two (2) ends of the bracket down to snap in place as shown. (Photo 2) 1A' • 3. Anchor Bracket to T-bar Grid A. Anchor bracket to t-bar grid with self tapping screw through bottom hole in bracket end into Ilir grid. Be sure to install self taping screw in lower hole of bracket end with attachment clip as shown. Repeat process on opposite end of bracket. Both ends of bracket should be anchored as shown. (Photo 3) '' °bar 0:.; !II . B. Thread the 3/8" bolt through side of universal hub. "� 1 . 4. Connect FlexHead to , Sprinkler Branch-line • Apply teflon tape and pipe sealant to one inch (1") - threaded end of FlexHead Sprinkler Drop per NFPA ak guidelines. Attach one inch (1") threaded end of FlexHead Sprinkler Drop to branch-tine per NFPA, State and local code guidelines. 5A The flexible hose with fitting is only intended to be installed with bends. Do not use welded or braided hose section of FlexHead Sprinkler Drop for a wrenching surface. Attach FlexHeadml 7-1 Sprinkler Drop using rigid pipe end of units as wrenching surface as shown. (Photo 4) 4 5. Secure FlexHead Sprinkler Drop to Mounting Bracket t' .- and Install Sprinkler Head �"" ,_ A. Bend the Flexhead to hold its desired position. Do not overbend the flexible hose. FlexHead has C. Adjust FlexHead Sprinkler height to a 3" (75mm) minimum bend radius per UL accommodate type of sprinkler head. When guidelines and 8" per FM guidelines. Insert sprinkler head is in desired location, tighten reducing coupling end of FlexHead Sprinkler Drop the fastening bolt on center hub of support through center hole in previously installed support bracket by turning clockwise hand tight plus bracket and hole in ceiling tile. Make sure the hose 1 turn (100 inch lbs) with wrench as shown. is bent sufficiently so that the reducing coupling sits After tightening the bolt, tighten the nut perfectly vertical in center hole of support bracket. hand tight plus 1 turn (100 inch lbs) with Do not torque or twist FlexHead during installation wrench. (Photo 5c) process. (Photo 5a) B. Attach sprinkler head, properly prepared with teflon 6. Installation of the tape and sealant to FlexHead Sprinkler Drop FlexHead Ceiling according to NFPA and sprinkler head manufacturer's Sprinkler System Is guidelines. (Photo 5b) p y WARNING! Complete These installation instructions are for qualified and/or licensed • Test installation of sprinkler system for any technicians in the Fire Protection field ONLY. Consult NFPA, FM, teaks per NFPA Guidelines. UL, state and local.code guidelines prior to installation. • Install sprinkler escutcheon from below ceiling Failure to follow these specific instructions may cause personal per manufacturers guidelines. injury. Installation technicians must read the entire manual prior to attempting installation of product. During maintenance or inspection of FlexHead product, facility fire protection system MUST BE INACTIVE. DO NOT ATTEMPT RELOCATION OR MAINTENANCE WHEN FIRE PROTECTION SYSTEM IS "LIVE." off, F exHea • commercia ire spnn er connections NFPA 13 Code Language and Seismic Qualification NFPA 13 Standard for Installation of Sprinkler Systems 2007 Edition 9.2.1.3.3* Flexible Sprinkler Hose Fittings. A. 9.2.1.3.3 Examples of areas of use include clean rooms, suspended ceilings, and exhaust ducts. 9.2.1.3.3.1 Listed flexible sprinkler hose fittings and its anchoring components, intended for use in installations connecting the sprinkler piping to sprinklers, shall be installed in accordance with the requirements of the listing including any installation instructions. 9.2.1.3.3.2 When installed and supported by suspended ceilings, the ceiling shall meet ASTM C-635 and shall be installed in accordance with ASTM C-636. 9.2.1.3.3.3* When flexible sprinkler hose fittings exceed 6 ft in length and are supported by a suspended ceiling a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft. A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based upon a comparison of the weight of a 6 ft, 1 in diameter sch 40 water-filled flexible hose fitting weighing approximately 9 lbs. The information provided to the committee showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was approximately 6 lbs and that a suspended ceiling meeting ASTM C-635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension of Acoustical Tile and Lay-In Panel Ceilings, and installed in accordance with ASTM C-636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels, can substantially support the load. In addition, the supporting material showed that the flexible hose connection can be attached to the suspended ceilings because it allows the necessary deflections under seismic conditions. 1.. FlexHead® Satisfies New Seismic Code Requirements Pipe nipple Typically, each unit consists of a threaded pipe nipple for Y�Y YYYY P P PP n'1 1Nm11HII-� IN �1N uu� i connecting to the main or branch rflrlf�VOett& _ feeder line, a flexible hose in 141�1�I' Sprinkler standard Lengths, a reducing fitting � branchline ,1 that the sprinkler head attaches to, 1j1��1, Flexible connecting hose in standard 1111j1 lengths—allows the head to move in and a mounting bracket. lli any direction during a seismic event without causing damage to the sprinkler system Mounting bracket ' Reducing fitting Suspended t-bar grid `� Ceiling tile Sprinkler head FlexHead Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council (ICC) acceptance criteria "ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Components'. This is the first time a sprinkler component has been seismically certified using test criteria accepted by the ICC. • More than 900/0 of the states in the U.S. are adapter through the ceiling to allow for free adopting the International Building Code (IBC) that movement of at Least 1 inch of ceiling address, among other things, the installation of fire movement in all horizontal directions. sprinkler systems in seismic zones. • Flexible sprinkler connection provide • The latest version of the IBC defers to ASCE 7 for characteristics that exceed the most stringent the sprinkler/ceiling design in Seismic Design seismic code requirements. The flexibility Categories (SDC) C and D, E & F. of the hose allows the head to move with • In Seismic Design Category C, suspended ceilings the ceiling in any direction during a seismic are to be designed and installed in accordance with event without causing damage to the Ceilings & Interior Systems Construction Association sprinkler system. (CISCA) recommendations for Zones 0-2; and • FlexHead Industries recently satisfactorily sprinkler heads and other penetrations shall have completed full-scale seismic qualification a minimum of 1/4-inch clearance on all sides. testing at the Structural engineering • In Seismic Design Categories D, E & F, suspended Earthquake Simulation Laboratory located ceilings are to be designed and installed in at the State University of New York at accordance with CISCA recommendations for seismic Buffalo using the International Code Zones 3 and 4 with some additional requirements. Council (ICC) testing standard "ICC AC-156 Except where rigid braces are used to Limit lateral Seismic Qualification Testing of deflections, sprinkler heads and other penetrations Nonstructural Components". shall have a 2-inch oversized ring, sleeve, or 4 FLEXHEAD FRICTION LOSS DATA AND SPECIFICATIONS Maximum Equivalent Outlet Hose Maximum Maximum Rated FlexHead Internal Orifice AssemblyMaximum Length of Schedule 40, Pressure I.D. Number of Nominal tin.Diameter Ambient Maximum Model# Size Length Temperature psi lkPa)/psilkPa) K-factor in 90-degree Bends Pipe,ft 4- Rating(cm) ft(cm) FM UL g F(6) Standard H-Series y 2024,2024H 1 1/211.27) 210.6) 3 18.4 11 300°(1489 175(1205)/300(2068) 5.62 2036,2036H 1 1/2(1.27) 3(0.9) 3 26.6 16 300°(148°) 175(1205)/300(2068) 5.62 2048,2048H 1 1/2(1.27) 411.2) 4 30.3 24 l 3000(148°) 175(1205)/300(2068) 5.62 2060,2060H 1 1/2(1.27) l 511.5) 4 35.8 29 300°(148°) 175(1205)/300(2068) 5.62 2072,2072H 1 1/2(1.27) 611.8) 4 45.6 35 300°(148°) 17511205)/300(2068) 5.62 2024 75,2024H 75 1 3/4(1 90) 2(0.6) 3 14.7 12 300°(148°) I 175(1205)/300(2068) 14.0 2036 75,2036H 75 1 3/4(1.90) ', 3(0.9) 3 21.8 18 300°(1489 175(1205)/300(2068) 14.0 2048 75,204BH 75 1 3/4(1.90) 4(1.2) 4 29.0 23 300°(148°1 1 175(1205)/300(2068) 14.0 2060 75,2060H 75 1 3/4(1.90) 5(1.5) 4 36.1 29 300°(148°) 175(1205)/300(2068) 14.0 2072 75,2072H 75 1 ! 3/4(1.90) 6(1.8) 4 43.2 32 300°(148°) 175(1205)/300(2068) 14.0 I 175psi,300psi 2024E,2024HE 1 1/2(1.27) 2(0.6) 3 26.4, 14.7 19 300°(140°) 175(1205)/300(20681 5.62 2036E,2036HE 1 1/2(1.27) 3(0.9) 3 30.1,21.8 23 300°(148°) 175(1205)/300(2068) 5.62 2048E,20481-1E 1 1/2(1.27) '� 4(1 2) 4 ' 33.8,29.0 27 300°(148°) 175(1205)/300(20681 5.62 2060E,2060HE 1 1/2(1.27) 5(1.5) 4 37.5,36.1 32 300°1148°) 175(1205)/300(2068) 5.62 2072E,2072HE 1 1 1/2(1.27) 6(1.8) 4 41.2,43.2 35 300°(148°) 175(1205)/30012068) 5.62 2024E 75,2024HE 75 1 3/4(1.90) 2(0.6) 3 14.7 18 300°(148') 175(1205)/30012068) 14.0 2036E 75,2036HE 75 , 1 l 3/4(1.90) 3(0.9) 3 21.8 23 300°(148°) 175(1205)/300(2068) 14.0 2048E 75,2048HE 75 1 3/4(1 90) 4(1.2) 4 29.0 23 300°(148°) 175(1205)/300(2068) 14.0 2060E 75,2060HE 75 : 1 3/4(1.90) 5(1.5) 4 36.1 29 300°(148°) 175(1205)/300(2068) 14.0 -2072E 75,2072HE 75 1 3/4(1,90) 6(1.8) 4 43.2 32 300°(148°) 175(1 2051/300(2068) 14.0 2036F 1.25 1 1/215.6) 3(0.9) 3 16,0 300°(1481 , 175(1205)/30012068) 5.62 q: 2048F 1.25 1/2(5.6) 4(1.2) 4 19.6 300°(148°) 175(1 205)/300(2068) 5.62 2072E 125 1/2(5.6) 6(1.8) 4 22 8 ! 300°(148°) �'l 175(1205)/30012068) 5.62 , I 2036F75 1.25 3/4(14) 310.9) 3 9 3 , 300°(148°) 17511205) 14.0 2048F75 1.25 3/4(14) 4(1.2) 4 11.4 300°(148°) 175(1205) 14.0 2072F75 1.25 1 3/4(14) 6(1.8) 4 15 300°(148°1 175(1205) I 14.0 2036F100 1 1.25 1 (14) 3(0.9) 3 7.1 300°(148°) 1I 175(1205) 22.4 2048F100 I 1.25 1(14) 4(1.2) 4 8.3 300°(148°) 175(1205) 22.4 2072F100 1.25 1 (14) 611.8) 4 10.1 300°(1489 175(1205) 22.4 Model Numbers:The"H"designates high pressure unit rated to 300 psig and the"E"designates elbow style unit. FLEXHEADU The"F"designates high flow rate using 1 1/4"internal hose diameter. FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pipe I N D U S T R I E S "-,°,s's sprinkler connections per NFPA 13,13R,and 13D guidelines.The hydraulic loss of the FlexHead connector needs to be included in the hydraulic design calculations the same as a valve or fitting.Each FlexHead sprinkler n. drop has a 3"minimum bend radius per UL guidelines, and a 8-minimum bend radius per Aatkore FM guidelines. A PART or IsrEaehnoaei **FM Equivalent Length Numbers include maximum "K"factor sprinkler head that is listed.** 56 Lowland Street, Holliston, MA 01746 ° Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend-radius.Different Toll-Free 800-829-6975 • Fax 508-893-6020 values were obtained by FM and UL due to the differences in minimum bend radius,testing protocol and calculation methods.Please see individual testing standards for more information relative to friction loss (Equivalent Length of Pipel. www.flexhead,com ©2013 Atkore International, Inc. All rights reserved. FXH-L-8040-1306 FlexHead Suspended Ceiling Detail Sprinkler 1 1 branch tine r'(plS, nexNead p'1 sprinklerdmp ¢14,� Ceiling grid mounting bracket ' Adjustable hub M_l ffil, Suspended kli1 t-bar grid Ceiling tile Sprinkler head (not included) Each FM approved and UL listed unit is ready to install, pressure- and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FlexHead Sheetrock Ceiling Detail 1 Cs Sprinkler if11 banch line j1VC W l sprinkler drop li Self-tapping Metal stud screw tYp.2 Adjustable hub , mounting backet Sheetrock ceiling Sprinkler head (not included) FlexHead 3" Bend Radius per FlexHead Shown with 3 Bends UL Guidelines (2 Bends Shown) -<--• w/ ^ ..Y14y L t i 4v r *Must have 8"bend radius per FM guidelines L . 6 F ex ' eas commercia ire spnn er connections Hose Specification Sheet Regular Model Elbow Model 1oAhSI NPT 1.20.1 T to ANSI 61.20.1 Typ. 304 SS Sch. B 40 Pipe B Weld per ANSI/AWS B2.1-00 Typ. 304 SS 401,i Braid Sleeve .A;,,�;� WO 44 4h1 :, Typ. 304 SS , ;e Corrugated Hose 1 inch true-bore internal diameter A provides lower A •i�? friction toss ;, A 5000 050 Typ. 304 SS 444? 40"8 Braid to prevent ,is%%i ,AAA elongation and improve 444 ;�, pressure retention ,;V VNI" titikit WO yore AA" Novo 444 Weld per ��4A� ANSI/AWS ;i,�;i B2.1 00 i 4 Typ. 304 SS %%.4 C Typ. SS outlet '- spud 1/2/2 & 3/4 inch di° female NPT threads to ANSI B1.20.1 Model it A (in.) B (in.) C (in.) D (in.) E (in.) 2024/2024E _ 24 3 4.5 1.5, 3, 4 3.5, 5, 6 2036/2036E 36 3 4.5 1.5, 3, 4 3.5, 5, 6 E 2048/2048E 48 3 4.5 1.5, 3, 4 3.5, 5, 6 2060/2060E 60 3 4.5 1.5, 3, 4 3.5, 5, 6 2072/2072E 72 3 4.5 1.5, 3, 4 3.5, 5, 6 7 Bracket Specification Sheet Multiport Design (For use with T-bar and Metal Stud applications) Model #: MP24BKT2 24" 11111 6" (4) 2.50" Chicago Grid applications): standard sizes are 16", 24" and 30" long Model #s: AD16BKT2/AD24BKT2/AD3OBKT2 16"/24"/30" 0.290" 1 � � 3 3.298"I 1.500 + 6" 1 El --2.33"/5"/5= ---233"/5"/5" .-2.33"/5"/5" " \ 7.74715.75"/15.75" ` 2.50" 2.375" 1.135" I 2.60" Adjustable Design (for use with T-bar, Metal Stud, and Chicago Grid applications): standard size 48" Long Model #s: AD48BKT2 _.. _ 48.2" 42.2" __. .._ 24" II2,362" - C C r — oo a • 0.7]5" 5" 5" 5" 14.5" 2.50" 8 F ex ' ea ' commercia ire spnn er connections FLexHead Commercial Products hot ._ ,,,' _ ,. _ 446111 1, _ ---w's+..- 1 .-." . _ 4,011 24", 36", 48", 60", 72" hose Lengths, 24", 36", 48", 60", 72" hose lengths. Rated working pressure 175psi, optional Rated working pressure 175psi, optional 300psi. 300psi. Straight model, Elbow model. Standard 1" I.D., optional 11/4" I.D. Standard 1" I.D., optional 11/4" I.D. Model #s: see page 5. Model #s: see page 5. r _ 24" Multiport Bracket for T-bar Grid or 16"/24"/30" Adjustable Bracket for Metal Stud applications. T-bar Grid, Chicago Grid or Metal Stud Model #: MP24BKT2 (standard bracket). applications. Model #s: AD16BKT2/AD24BKT2/AD3OBKT2. 1 Ng f ., 1 Hat Channel Bracket System for Metal v' Stud or Hat Channel applications. Model #: AD24BKT2 with BKT-HTA. Armstrong TechZone Ceiling Bracket A Alt ANL for use with Armstrong TechZone Ceiling systems. Available in both 4" and 6" long. Model #s: SPO4BKT2/SPO6BKT2. 48" Adjustable Bracket for T-bar Grid or Bracket for Confined Space applications Metal Stud applications. having a concrete deck above the ceiling. Model #: AD48BKT2. Model #: UH-2. 9 Examples where Flexible Sprinkler Hose Fittings are used : ...•• - 7,— f .�-r :, c ® us r i LISTED } 11> t r h APPROVED i&r,,,„....4402050,„ Suspended Ceilings Exhaust Ducts 4 i r I Ai y . { Institutional Cleanroom Ceilings Flexible Sprinkler Hose Fittings were Underwriters Laboratory and FM developed to satisfy specific needs of the approvals and are tested to approval industry, save the industry millions in losses, standards that were independently provide superior seismic protection and developed by the testing laboratories. promote the installation of sprinklers. They The first listing for a Flexible Sprinkler have been evaluated for use by both Hose Fitting was in 1990. 10 F exHea commercia ire spnn er connections Testing and Approvals FM Global Testing —Approval Standard FM1637* FlexHead' series 2000 stainless steel sprinkler connections Hydrostatic Strength Test Pressure Cycling Test A sample FlexHead was subjected to a hydrostatic A sample FlexHead was filled with water and bent pressure of four (4) times the rated working at a 90° angle and subjected to 20,000 cycles of pressure of 175 psi (1205 kpa) to 700 psi (4825 pressure varying from 0 psi (0 kpa) to 175 psi kpa) for a period of five minutes. The assembly (1205 kpa) at a rate of approximately 6 cycles per showed no signs of rupture, cracking, permanent minute. After the successful completion of the distortion, or deterioration of performance pressure cycling tests the sample was subjected to characteristics. The FlexHead successfully passed the hydrostatic pressure test at 700 psi and this test. showed no signs of deterioration. The FlexHead successfully passed this test. Vibration Test A sample FlexHead was secured to a vibration Fatigue Test table. The FlexHead hose was bent in a 90° angle A sample FlexHead was subjected to 50,000 cycles and pressurized to 90 psi (620 kpa) and the of repeated flexing at a rate of 5 to 30 cycles per mounting bracket and hose were then subjected to minute per section 8.3 of ISO standard 10380. a total of 25 hours of severe vibration conditions. After the successful completion of the fatigue test After the successful completion of the vibration the sample was subjected to the hydrostatic tests the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed deterioration. The FlexHead successfully passed this test. this test. Head Deployment Friction Loss (Equivalent length of pipe) A sample FlexHead installed in a suspended ceiling To determine the effect of the FlexHead to the was fitted with a sprinkler head and pressurized to discharge coefficient of the sprinkler, the average 26-175 psi. The sprinkler head was then activated friction loss through the FlexHead shall be by a heat source at various pressures, and the equated to the theoretical length of nominal 1" sprinkler head deployed. The assembly showed no diameter schedule 40 sprinkler pipe which would signs of distortion or deterioration of performance produce the same amount of friction loss. Please on the assembly or sprinkler head. The FlexHead see friction loss table. successfully passed this test. Vacuum Test A sample FlexHead was subjected to a vacuum of 25 inHG for a period of five minutes. After the successful completion of the Vacuum Test the sample was subjected to the hydrostatic pressure test at 700 psi and showed no signs of deterioration. The FlexHead successfully passed this test. Condensed Summary—Please see approval standard for full testing and approval criteria. 11 APPROVED FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR COMMERCIAL SUSPENDED CEILINGS Flexible sprinkler hose with threaded end fittings are for use in commercial suspended ceilings. The flexible hoses are to be installed according to the manufacturer's directives. Unless indicated, the hoses have a rated working pressure of 175 (1205 kPa). Flexhead Industries, Inc. 56 Lowland St, Holliston MA 01746 `Model NPT in. Hose Assembly length ft (m) This is a standard flexible hose with a pressure 2024/2024 75 1/2 / 3/4 2 (0.6) rating of 175 psi (1205 kPa). Approval on these models of flexible metal sprinkler hose is 2036/2036 75 1/2 /3/4 3 (0.9) - _) limited for use in commercial suspended 2048/2048 75 1/2 / 3/4 4 (1.2) i ceilings, with a ceiling bracket system 2060/2060 75 1/2 / 3/4 5 (1.5) manufactured by FlexHead Industries Inc. The 2072/2072 75 1/2 / 3/4 6 (1.8) brackets are identified below. Model 1 NPT in. Hose Assembly length ft (m) This is a standard flexible hose with a pressure -, rating of 175 psi (1205 kPa). Approval on these 2024E 1/2 2 (0.6) models of flexible metal sprinkler hose 2036E T 1/2 3 (0 9) incorporates a stainless steel elbow welded on 2048E 1/2 4 (1.2) the outlet end of hose and are limited for use in 2060E 1/2 5 (1.5) . commercial suspended ceilings, with a ceiling 2072E 1/2 6 (1.8) bracket system manufactured by FlexHead Industries Inc. The brackets are identified below. Model NPT in. Hose Assembly length ft (m) The "H" designation indicates a pressure rating - i of 300 psi (2070 kPa). Approval on these 1/2 2036H 1/2 3 0.9 models of flexible metal sprinkler hose is ( ) ( ) limited for use in commercial suspended 2048H 1/2 4 (1.2) ceilings, with a ceiling bracket system 2060H 1/2 { 5 (1.5) manufactured by FlexHead Industries Inc. The 2072H 1/2 1 6 (1.8) brackets are identified below. Model NPT in. Hose Assembly length ft (m) The "I" designation indicates and "Institutional" flexible hose with a pressure 2024I 1/2 2 (0.5) rating of 175 psi (1205 kPa). Approval of these 2036I ! 1/2 3 (0.9) models of flexible metal sprinkler hose is 2048I 1/2 4 (1.2) limited for use with pendant and horizontal 120601 1/2 5 (1.5) sidewall applications with a UH-1 ceiling/wall 12072I 1/2 6 (1.8) bracket manufactured by FlexHead Industries. The different FlexHead Industries, Inc. Brackets are identified as follows: Part Number MP-24-BKT-2 SP-06-TZ-BKT TZ =Tech Zone 06 = Length in inches of bracket - AD-16-BKT-2 AD = Adjustable 16 = Length in inches of bracket AD-24-BKT-2 24 = Length in inches of bracket - AD-30-BKT-2 BKT = Bracket 30 = Length in inches of bracket AD-48-BKT-2 48 = Length in inches of bracket 1t n F ex ea ' commercia ire spnn er connections Testing and Listings Underwriters Laboratory Testing — Listing Standard UL2443 * FlexHead series 2000 stainless steel sprinkler connections Hydrostatic Pressure Test Stress-Corrosion Cracking of Stainless Steel The sample length is to be measured and then the Parts Test hydrostatic pressure increased to 1.5 times the rated Austenitic stainless steel parts shall show no evidence working pressure and held for 1 minute. The sample of cracking, delamination, or degradation after being length is then to be measured again and the length subjected to boiling magnesium chloride solution. The shall not change by more than 0.1 inch/foot of hose exposure is to last for 150 hours. The test samples are length. to be examined using a microscope having a Mechanical Strength Test magnification of 25X for any cracking, delamination, A flexible sprinkler hose with fittings installed in its or other degradation as a result of the test exposure. intended position using the anchoring components Low Temperature Test for Dry Pipe Systems referenced in the installation instructions shall Each sample is to be gradually pressurized with air to withstand a torque of 60 pound-feet (81 Nm) applied to a pressure of 40 psig (276 kPa) and then sealed. The the outlet without movement of the fitting outlet, pressurized assembly is then to be placed horizontally deformation, or fracture. in air maintained at a temperature of minus 40°F High Temperature Exposure Test (minus 40°C) for a period of 24 hours. Following the Two samples are to be prepared and subjected to a 24 hour low temperature exposure, the assembly is to hydrostatic pressure of twice the rated working pressure. be place in room ambient temperature of 73 ±5°F The samples are then to be allowed to dry and then (23 ±3°C) for an additional 24 hour period. There exposed to an ambient temperature in accordance with shall be no decrease in the pressure in the assembly Table 10.1 for 90 days. Following this exposure, the from the pressure measured before the low samples are to be individually subjected to a temperature exposure. hydrostatic pressure of twice the rated working pressure Pressure Cycling Test for 1 minute. The samples are to be connected to a pressure cycling Vibration Test apparatus, filled with water and vented of all air. Samples are to be vibrated for a period of 30 hours at The internal pressure is to be cycled 3,000 times frequencies ranging from 18 to 37 Hz. During and after from 0 psig (0 kPa) to twice the rated working being subjected to the required vibration, the samples pressure to 0 psig (0 kPA) at an approximate rate are to be examined for signs of leakage, rupture, or of 10 cycles per minute. During the pressure cycling, movement of the outlet fitting affecting the observations are to be made for evidence of leakage performance of the flexible hose assembly. or physical damage. Equivalent Length Determination Vacuum Test A sample of each length shall be tested in straight Flexible sprinkler hose with fittings shall withstand lengths and with the maximum number of minimum a vacuum of minus 8.84 psi (minus 61 kPa) without radii bends referenced in the installation instructions. collapse, leakage, or other deterioration of the flexible The calculated pressure loss from the piezometers, sprinkler hose and fitting performance characteristics. corrected for the inlet and outlet velocities, are to be High Pressure Flow Test subtracted from the test sample results to obtain a Flexible sprinkler hose with fittings and its anchoring pressure drop for the fitting. Using the Hazen-Williams components shall maintain the attached sprinkler in coefficient of friction of 120, the equivalent length, in the intended operating position while the sprinkler feet (m) of pipe, is to be calculated. discharges water at 90 percent of the rated pressure of Salt Spray Corrosion Test the flexible sprinkler hose. Ferrous flexible sprinkler hose with fittings and ferrous Fatigue Test (Limited Flexibility) anchoring components not protected with a coating Flexible hose with fittings shall withstand without shall withstand an exposure to a salt spray atmosphere leakage or damage repeated flexing in a direction for 10 days without exhibiting any incipient corrosion. parallel to the axis of the end fittings. The number of flexing cycles shall be 100 cycles. 13 * Condensed Summary—Please see approval standard for full testing and approval criteria. • Testing and Listings Underwriters Laboratory Testing—VENF.EX5269 Flexible Sprinkler Hose with Fittings See General Information for Flexible Sprinkler Hose with Fittings FLEXHEAD INDUSTRIES EX5269 LOWLAND IND PARK 56 LOWLAND ST HOLLISTON, MA 01746 USA Equivalent Max Length of 1 in. Rated Nom Inlet Assembly Max Schedule 40 Pressure Ambient by Outlet Length No. of Min Bend Steel Pipe Flexibility Model psig Temp, °F Size,in. ft (mm) 90° Bends Radius,in. (C=120),ft Type 2024 175 300 1 by 1/2 2 3 3 11 Limited ..........00 2036 175 300 1 by 1/2 3 3 3 16 Limited 2048 175 300 1 by 1/2 4 4 3 24 Limited 2060 175 300 1 by 1/2 5 4 3 29 Limited 2072 175 300 1 by 1/2 6 4 3 35 Limited 2024 175 300 1 by 3/4 2 3 3 12 Limited 2036 175 300 1 by 3/4 3 3 3 18 Limited 2048 175 300 1 by 3/4 4 4 3 23 Limited 2060 175 300 1 by 3/4 5 4 3 29 Limited 2072 175 300 1 by 3/4 6 4 3 32 Limited 2024H 300 300 1 by 1/2 2 3 3 11 Limited 2036H 300 300 1 by 1/2 3 3 3 16 Limited ` 2048H 300 300 1 by 1/2 4 4 3 24 Limited 2060H 300 300 1 by 1/2 5 4 3 29 Limited 2072H 300 300 1 by 1/2 6 4 3 35 Limited 2024H 300 300 1 by 3/4 2 3 3 12 Limited 2036H 300 300 1 by 3/4 3 3 3 18 Limited 2048H 300 300 1 by 3/4 4 4 3 23 Limited 2060H 300 300 1 by 3/4 5 4 3 29 Limited 2072H 300 300 1 by 3/4 6 4 3 32 Limited 2024E 175 300 1 by 1/2 2 3 3 19 Limited 2036E 175 300 1 by 1/2 3 3 3 23 Limited 2048E 175 300 1 by 1/2 4 4 3 27 Limited 2060E 175 300 1 by 1/2 5 4 3 32 Limited 2072E 175 300 1 by 1/2 6 4 3 35 Limited 2024E 175 300 1 by 3/4 2 3 3 18 Limited 2036E 175 300 1 by 3/4 3 3 3 23 Limited 2048E 175 300 1 by 3/4 4 4 3 23 Limited 2060E 175 300 1 by 3/4 5 4 3 29 Limited 2072E 175 300 1 by 3/4 6 4 3 32 Limited 2024HE 300 300 1 by 1/2 2 3 3 19 Limited 2036HE 300 300 1 by 1/2 3 3 3 23 Limited 2048HE 300 300 1 by 1/2 4 4 3 27 Limited 2060HE 300 300 1 by 1/2 5 4 3 32 Limited 2072HE 300 300 1 by 1/2 6 4 3 35 Limited 2024HE 300 300 1 by 3/4 2 3 3 18 Limited 2036HE 300 300 1 by 3/4 3 3 3 23 Limited 2048HE 300 300 1 by 3/4 4 4 3 23 Limited 2060HE 300 300 1 by 3/4 5 4 3 29 Limited 2072HE 300 300 1 by 3/4 6 4 3 32 Limited These flexible sprinkler hose with fittings are intended to be installed in accordance with the manufacturer's - installation instructions. Copyright u 2009 Underwriters Laboratories Inc© Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc. - The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow- Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-UpService.Always look for the Mark on the product. 14 4A ff IQUIPMENT ATCHORAGE & SIBISfr fDvaDeERwo wittor.tolufpoactin.1)0.140*.coo . ---......... FLEXHEAD INDUSTRIES .3., R. LA BRIE mart - me ma 11-0X8 1 FLEXHEAD SPRINKLER CONNECTIONS MODEL # 2024, 2036, 2044 2060, 2072 °AM 9/241°9 0 2 %MHZ ANLNORASE FRE-AFFP,M2D misti mute Fte(f Office of Statewide Health Planning and Development ANCHORAGE PRE-APPROVAL •-‘"tiiia:`004., OB.Hi. = tAl L . MAX. 4ze.SZP4, Ar"." liz:Pis. EraSTINS MOIR SLPFLT LAC ......,70. PER MA EOM Lite, 4.4... eA.CALVANIZED Or I9491NWIR OF MORD) TAP.; r.z.4., 5NEET METAL .,P... .: . imm In 20&A.SALVN4ZEO FE ):WAD ERA 111 514±T METAL Thaffk ReSISTANT 54AF5 ONTO Me- 5CREM5(0 ON EAC*I r-eAR CEILIN5 -FROV1P63 Eff 1.1111111.110.1111 inliel R150-EAP 11011.11111111111111Nrh.. r-sAR GEILIN&efao N, 5FROKLER HEAD 3,03"BOLT NTH Or EN5NESZ OF FKORG0 r13-r 0riiiiR5) MCKIM&wr GENERAL NOTES! ELEVATION I. A)CI-IMNOE DE504 PEI< 2001 CALIFCRNIABOtiMa COG - 5EC1IONI6I3A Ali) ASGE 7-05 SEC-5%512 AND 13. ALLOHABLE STRESS pt-steN 15 05E0. HORIZONTAL FORCE (Ed '.- 2.43 Hp(5us a I. I p't. I.5r 0 p 1 25, Ft r 23) VERTICAL FORCE (Ev) = 0.21 Hp 2. El'OttER Of RECORD FOR The t3t1ILDIN6 5FIALL PROVIVE SUPPORT 5TROCTURE DE5119FIED TO SUPPORT k€119HT5 AND FORCE5 5H044.1. 3. EtseINEER C4 RECORD TO VERIFY CaVECTION HILL PERMIT AVEGVATE DI " ; i IN ALL DIRECT-10Na I i w II ilf r , APPROVED Fixed EquipMent Ariellonage • •--• x - ei 1 lira e CeaterEllelealcia Hoak Plovong ind Dirvalopairt ••:. ..0 S'fillillillitA DPA-0672-07 No. 3566 i przALP-.,',1:ji AmIkely IR Pin '.aS DA 341- 02 ' lirMr F V *NV (111114040401 * 41' f ir24,1D1 N. * , 624 15 ' c k vb- fu,....edht47.4 . "A ANCHORAGE a SHAW iii41011WERPIG www.eautpreeetikeekeirete.ease FLEXHEAD INDUSTRIES Dm it. m BRIE SIM oda ea 111-07118 2 FLEXHEAD SPRINKLER CONNECTIONS MODEL # 2024E 2038E 204,8E, 2080E 2072E DIM "VW 2 5riStikl AVOW EPE-AP(SCW0 MAD AT SHEETPmA at* CEILDIEP Warr Office of Statewide Health Planning and Development ANCHORAGE PRE-APPROVAL EM-(145 Wk/ER 5UPPLY LINE PER NITA GIME Oa Ceir EN9NEER OP Przr.0PD) 6,4 L .MAX 40 DE6 EL0h lih. W Kf't*:..M1c$1.1PAQW:i4Z•7411.'",:ik;:k5 ,.**WrOtii4.4,;k•Al mil lib 6A_&ALVA/117E2 MEET TETA1- ___ 20 erA_6ALVANLVD I/4'SELF TAPPING' ..1;0451 (2) COI EAGI-I BID Weer l'oETAL- i..---'\\*41 ro 4.1 - 61,51.1h1 WARP GC-Ltra5 PIT14 PETAL(CYR 140teVEN) SPRINKLER MAO 5.43' Bcu lin FRAM MEMBER (Eh'°TIERS) BACK**Nit Or aisnem cF RE4ORRI ELEVATION ODER& P01E51 I. ANGHORACJE DESCati PER 2001 CALIFORNIA BUILDING, COVE - '5EC:110N 1613A AIV ASCE 1-05 SECTIONS 12 NV Et ALLOWABLE STRESS DESIGN IS MED. HORIZONTAL FORCE (Eh) . 2,43 ltip On .. 1,q3, I p z 15, p. 25,,R p. 25) VERTICAL FORCE (E) L.- 0.21 Pip 2, ENBIILFER Of RECORD FOR THE Elf,LI*6 SHALL PROVVE SIPPORT STRUCTRE DESIGNED TO SUPPORT V.E115,HT5 NV FORGES 94041. 3. 13,0REER OF RZGO ) TO VERIFY CCWECTION WILL PERMIT AVEIXATE VI - - 2 . IN ALL DIRECTM, III III APPROVED pimao equipment Anchorage,• ,..7. , Onitili Of 60404000.Hiatt Pttiewirla*nil D ~onl $ 1 401111%‘,- OPA-0676-07 I4o. 3566 i a. ' 41 ihreow,R Pia I" 4011446,006 EV. 3-3‘2011) ',.. lorleiv "'Plural tl . .0.• t 4;ritt.jf"4111 . • .rrently enforce expiration dates. All pre-approvals are VE id regari o ex irati"? I • l. C A CI listimireil Br. OWN 1 6 • 3-32i Pingtr, I 1k1 i SLirr[gritty raua I Pi FP'Oaf I Lr - topftvorimp Omni C ® US Underwriters Laboratories Inc.` LISTED a Cahn K �k. 11044101 June 21, 2001 FlexHead Industries Mr. Norm MacDonald 56 Lowland St. Holliston, MA 01746 Our Reference: File EX5269 Subject: FlexHead Flexible Sprinkler Hose Fittings Installed Onto Dry Wall Ceiling Grid Dear Mr. MacDonald: This letter is in regard to the subject. Base upon review of the FLexHead UL Listed flexible sprinkler hose fitting system, installation onto a dry wall ceiling grid is acceptable when the ceiling-mounted bracket is screwed to a rigid surface. Self-tapping screws are used to affix the FlexHead mounting bracket to the surface, using the four ports provided which are pre- drilled onto the mounting bracket. Very truly yours, EMIL W. MISICHKO (Ext. 42036) Engineering Group Leader Conformity Assessment Services Department 3011CNBK Emil W. Misichko@us.ul.com A not-for-profit organization dedicated to public safety and committed to quality service 17 National Fire Protection Association • PFtA: wri it21 4T #'Min. P I, ,�' •• n r..wl!1 M-n-wmlru.��, November 15,201)6 Mr.Norman MacDonald President Plead Iced industries,ine. 56 Lowland Street Holliston,MA 01746 1=ax: 50S-8934020 Dear Mr.MacDonald, "lids le is in response#o your email dated November 13, 2006 which disenamd listed flexible sprinklerltoses,specifically FtcxHeed. Your question relates to the acceptability of listed technology which was not specifically) addressed it previous editions ofNEPA 13, including the 19e9 and 2042 edition€, NFPA 13, 1990 Section 1-2 and NFPA 11,2002 Section 1,6 provide specific text that addresses new technology. It is the intern of tiro current and previous editions of NFPA 13 to allow the use of listed technologies where they are not specifically addressed in NPI'A 13. The base requirement is that they Ix installed incomptianee with all or the listing requirements and manufacturers' instructions. These statements have been provided by the technical committees to address the very situation that you have described In essence, where a new technology is developed.tcstcd and listed as acceptable for automatic fire sprinkler use it can be utilized in accordance with NFPA 13 with no additional requirements other than those in the listing.and manufacturers" Instructions. In summary it is the intent ofNFPA 13 to permit the use of technologies,equipment and materials not specifically addressed in NFPA 13 where they are specifically listed for fire sprinkler use and where they have been installed in accordance with the listing requirements and the manufacturers' instructions_ Please be aware that this response does nut constitute a Formal interpretation as explained in the Important Notice below_ >; : fully iI j isn D rrP_L. Principal .. Protection En incur TiFPA 13 S1a r rile NFPA 13 • Important-Notice: This correspondence is not a Formal Interpretation issued pursuant to NFPA regulations. Any opinion expressed is the personal opinion of the author,and does not necessarily represent the official position ofdtt NEPA or its`technical Committees. In addition, this correspondence is neither intended, nor should be relied upon, to provide professional consultation or services 18 • (BUILDINGS rdr'�[hbGmK�nl M BWningn Q?w l Gadidne, JP.Ii timaciony,'dew Vco.oii'+'ridonT amain, Pdifl.HI Layend d,Frirsa Cmmrt'bObnor taraiairi and kat+pm:nArzodkomn kiici :1,25ai99 n- 2 1E ow 4F17 S66-181 l F-nMll;ilnir el4�u �uA1Jiy�a�i�4ier July 17, 2007 h4r_Paler M_ MacDonald FlaxHead InUu,.t*ies 56 L..awtand Street Holliston, MA 0170 Dear M . MacDonald. Enclosed is a final ofTciiai signed copy al MEA acceptance of yecur product MEA261411r5S212. Wilton yaw may use as proof pf your product.acceptance 1n New York City. Thia document, logged r with proper labeling and installation in acc+ardance with New York,Clty Euilrling Code, wilt enable the inspector to kr v that the product installed is letisi. Attainments tints and dethrones of accepted rrratertaIs to the job ails ant required to be lac*d or tagged in accordance with Lie format below: • Accepted Por Use City of New York Department of Buildings MEA2{f7-40-F Vol.3 Company Name Sintetyl, orrairt Gottfried, P.E. } G: Oatmeal IF.Tlaylos,A1,A, LEED AP Executive Dirtctnr, special Projects aria MEA f gaiety service integrity 19 F ex ea ' commercia ire sprin er connections Limited Warranty • FlexHead Industries, Inc. warrants that its products will specifications, instructions or recommendations, be free from defects in materials and workmanship under including, without limitation, our normal conditions of use and service for a period of one recommendations as to following the inspection year from date of sale. Our obligation under this and maintenance standards published by Factory warranty is limited to repairing or replacing any product Mutual Research Corporation (FMRC) and the that is returned to us with transportation charges National Fire Protection Association (NFPA); and prepaid within one year after the date of original sale (h) products that have been affected by and that our examination shows to our satisfaction to Microbiologically Influenced Corrosion (MIC). This have been defective in materials or workmanship under warranty is not assignable and shall benefit only normal conditions of use and service. The decision as to the original purchaser of a FlexHead Industries, whether to repair or to replace any product shall be Inc. product. If any provision hereof or any portion made by us, and any repair shall be made at our facility. of any provision shall be held invalid, the Notwithstanding the foregoing, the following are remainder of this Limited Warranty shall not be specifically excluded from the coverage of this warranty: affected thereby, and all provisions of this Limited (a) the sprinkler head of any FlexHead Industries, Inc. Warranty shall remain valid and in full force and product, but FlexHead Industries, Inc. hereby assigns to effect to the fullest extent permitted by law. THIS the original purchaser of any such product the right to WARRANTY IS IN LIEU OF ALL IMPLIED enforce the warranty, if any, issued by the manufacturer WARRANTIES, INCLUDING, BUT NOT LIMITED TO, of such sprinkler head; (b) defects resulting from WARRANTIES OF MERCHANTABILITY AND ordinary wear and tear, including, without limitation, WARRANTIES OF FITNESS FOR A PARTICULAR the replacement of the so called poly bag components of PURPOSE. NOTWITHSTANDING ANY PROVISION TO any FlexHead Industries, Inc. product; (c) products that THE CONTRARY HEREIN OR ANY APPLICABLE LAW have been altered in any manner by the buyer or by TO THE CONTRARY, IN NO EVENT SHALL FLEXHEAD • anyone other than FlexHead Industries, Inc.; (d) INDUSTRIES, INC. BE LIABLE FOR INCIDENTAL OR products that have been subjected to misuse, abusive CONSEQUENTIAL DAMAGES UNDER ANY use, or damage by accident or casualty; (e) products CIRCUMSTANCES WHATSOEVER, WHETHER ARISING that have been installed or used in a manner contrary to FROM ANY BREACH OF THIS LIMITED WARRANTY OR our specifications, instructions or recommendations, (f) OTHERWISE ARISING FROM OR IN CONNECTION products that have been installed or used in a manner WITH THE USE OR OPERATION OF, OR ANY DEFECT that is not in compliance with all applicable IN, ANY FLEXHEAD INDUSTRIES, INC. PRODUCT, OR requirements of any code, law, regulation or rule of any OTHERWISE. The risk of damages from any breach federal, state or local governmental or industry of warranty with respect to injury to any person authority; and (g) products that have not been will be born by the purchaser of FlexHead inspected and maintained in accordance with our Industries, Inc. product. f t F ex ea ' commercia ire span er connections Your security is our business. FlexHead Industries was founded in 1992 to help engineers, builders and owners increase the safety of their buildings. Our patented sprinkler connection technologies show that it's possible to comply with codes cost-effectively. We're proud to help • IN reduce the risks of property damage and - loss of life in a wide variety of buildings, ,. ' domestically and world-wide. FlexHead manufactures sprinkler connections for all types of applications including: ""*` ' Commercial Exhaust ducts Institutions o Government Aerospace Concrete penetrations • Hospitals Automotive for sidewall and a • Offices pendant applications Seismically Biotechnology Restaurants : Electronics k= Correctional centers qualified. Retail Forest products/ `' Mental health facilities FlexHead connections allow Schools paper pulp for independent movement Laboratories between sub-mains and Cleanrooms ceilings. They're the only a Biotechnology Petrochemical flexible sprinkler connection Electronics ,, Pharmaceuticals to be qualified for use in High end commercial Restaurants Seismic Design Categories ceilings ^. Semiconductors C, D, E and F. hT;: Pharmaceuticals i Steel manufacturers Semiconductors FL EXHEA P • • INDUSTRIES Arlo. u� os � The pioneers in flexible fire protection a F U.S.and international patents pending:#6,123,154,#6,119 784;""`"" "`°'"-56 Lowland Street n6,752,218,a7,032,680, u6,488,097. Holliston, Massachusetts 01746 The FlexHead name and logo are trademarks of FlexHead Industries. toll-free 800-829-6975 FBCTM System Compatible indicates that this product has been tested,and is ` monitored on an ongoing basis,to assure its chemical compatibility with (508) 893-9596 FlowGuard Gold', BlazeMasterx and Corzan®pipe fittings.FBCTM, FlowGuard fax (508) 893-6020 Gold®,BlazeMastera and Corzan are licensed trademarks of The Lubrizol Corporation. info@flexhead.com USGBC' and LEED are registered trademarks of the U.S.Green Building Council. www.flexhead.com SDP/03-02-12