Loading...
Permit ICITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2019-00124 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: O6/03/2019 TIGARD Parcel: 1 S135AA03800 Jurisdiction: Tigard Site address: 10413 SW AKILEAN TER Subdivision: OAK STREET CONDOMINIUMS Lot: 25 Project: Oak Street Condominiums, Lot 25 Project Description: New SFA. Building 4. REPRINT to add A/C and mini-split. Placement of A/C must meet manufacturer's requirements. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 559 sf Basement: 114 sf Left: 0 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 552 sf Garage: 409 sf Front: 0 Smoke Dwelling Units: 1 Third: 0 sf Right: 0 Detectors: Yes Total: 1225 sf Value: $165,511.85 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 4 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 1 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vacuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1225 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 11807 NE 99TH ST STE 1170 11807 NE 99TH STREET SUITE 1170 1 2 Hour Fire Assemblies VANCOUVER,WA 98682 VANCOUVER,WA 98682 2 1 Hour Fire Proofing 3 Ersn Cntrl 503-639-4175 PHONE: 360-258-7900 PHONE: 360-949-9128 FAX: 360-258-7901 Total Fees: $22,495.91 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law require you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OA 952-00 0090. u may o in a co of the rules or direct questions to OUNC by calling 503.232.1987 r 1.800.332.2344. i. SC. Issued By: Permittee Signature: CY!��� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. V/ �y This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. 1. Mechanical Permit Application (�9 I OR OF i l( I: I SI.:ON i. JlskiL Received / / City of Tigard y /I v��/ �-Z • 13125 SW Hall Blvd.,Tigard,OR 9722i _--�/ rip-n t. d i Da e/a i / Phone: 503.718.2439 Fax: 503.598.1960 x 'J . Ptah Review Date/By: Other Permit: Ili I ,Sires TIGARD Inspection Line: 503.639.4175 i'.: k;!v1.�1 i- Date Ready/By: Suns: lid See Page 2 for Internet: www.tigard-or.gov Notified/Method. Supplemental Information TYPE OFW'ORK COMMERCIAL FEE* SCHEDULE'— USE CHECKLIST - - Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed. Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION s'm *_ -- - - RESIDENTIAL EQFif[PMEN�'/- s-.M$EEE$* ® 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building For special information use checklist. ❑ Multi-family ❑Master builder ❑Other: Description Qty. Ea. Total JOB SITE INFORMATION. AND LOCAi'IQ1'a1 '; Heating/cooling: .r� •>x Air conditioning 1 46.75 Job site address.10413 SW Akilean Terrace Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Furnace 100,000+BTU(ducts/vents) 54.91 Suite/bldg./apt.no.: Project name: Heat pump 61.06 Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:Cornerstone Condominiums Lot no.:25 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 Flue vent for water heater or gas NSFR attached fireplace 23.32 `add A/C and mini-split to existing permit # MST2019-00124 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER '77'"51, :ITENANT Other: 23.32 - Environmental exhaust and ventilation: Name:Lennar NW Inc. Range hood/other kitchen equipment 33.39 Address:11807 NE 99th St. #1170 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver, WA 98682 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(360 )258-7900 Fax:( ) Attic/crawlspace fans 23.32 0 APPLICANT 0 CONTACT PERSON Other: 23.32 Business name.Same as above Fuel piping: -- $14.15 for first four;$4.03 for each additional Contact name:Juts Call Furnace,etc. Gas heat pump Address: Wall/suspended/unit heater City/State/ZIP: Water heater Phone:(360)258-7906 Fax::( ) Fireplace Range E-mail: 'uls.call@lennar.com Barbecue : CONTRACTOR Clothes dryer(gas) Other Business name:HeatGuy, Lt. MECRANICALPERMIT FEES* Address:5215 NE 282nd Ave Subtotal City/State/ZIP:Camas, WA 98607 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(360 253 4822 Fax:( ) State surcharge(12%of permit fee) CCB lie.:187461 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 _ days after it has been accepted as complete. Authorized signature: ------— • Fee methodology set by Tri-County Building Industry Service Board Print name:Corinna Fri Date:04/15/2019 I:\Bs1ding\Permiis\MEC_PermiiApp_0401 13.dor 440-4617T(I I/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 -Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation: Permit Fe € w' m $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2