Report (4)
'1o!/-moz6 IA,go clffifgeaehresrerav Hydraulics Summary Sheet FIRESTOP COMPANY Designer: RD GREEN 3203 NE 65TH STREET SPACE 2 Colc By: RD GREEN VANCOUVER, WA. 98663 Date: 1/5/2011 360-718-8604 Project Information Hydraulics Information DOW AGROSCIENCES BLDG.0 T.I. 16160 SW UPPER BOONES FERRY ROAD Demand... TIGARD, OR. 97224 Spr Req'd Pres: 81.40 PSI MRA #1 Spr Req'd Flow: 249.03 GPM Add'I Flows: 0.00 GPM Hose at Srce: 0.00 GPM Contract No: Total Flow: 249.03 GPM Building: BLDG.0 LAB E 100 Total Pres: 81.40 PSI System ID: DOW AGROSCIENCES TI MRA #1 Static Elev: 0.00 Ft Ref. Drawing No: 1 OF 1 Construction: 9' SMOOTH CEILING Supply... Water Flow Test Occupancy: LAB AND OFFICES Static: 105.00 PSI Authority: CITY OF TIGARD Residual: 76.00 PSI Qty Flowing: 852.00 GPM Elevation: 0.00 Ft System Information Date: Time: By: Hydraulics Design Criteria_ Pump Data System Type: WET Rated: 0.0 PSI@ 0.0 GPM Density: .1S GPM/SciFt Boost Pres: (NA) PSI Remote Area: 1.260 SqFt Discharge Pres: (NA) PSI Sprinkler Coverage: 324MAX SqFt Discharge Flow: (NA) GPM Design Standard: NFPA #13 (2007) Combined Hazard: ORDINARY GROUP 1 Static: (NA) PSI Figure: 1123231 Curve: Residual: (NA) PSI Sprinklers / Nozzles_ Qty Flowing: (NA) GPM Manufacturer: RELIABLE Available... Model: JL112 Size: 3/4" NPT P)102.02 PSI@ 249.03 GPM K—Factor: 11.2 F) 81.40 PSI@ 762.36 GPM Temp. Rating: 165E Margin... Pressure: 20.63 PSI l Flow: 513.34 GPM Sigma Dynamics Corporation 7700 Summary Sheet/ SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 1 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 FLOW TEST RESULTS Water Supply STATIC 105 .00 PSI RESIDUAL 76 . 00 PSI @ 852 . 00 GPM CITY PRESSURE AVAILABLE AT 249 . 0 GPM 102 .02 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 101 51 .71 49. 00 11 . 20 21 .32 102 49 .68 49. 00 11 .20 19. 67 103 49 .00 49 . 00 11 .20 19 . 14 104 49 .48 49. 00 11 .20 19 . 52 105 49 .15 49 .00 11 .20 19.26 TOTAL WATER REQUIRED FOR SYSTEM 249 . 03 GPM TOTAL WATER REQUIREMENT 249 . 03 GPM PRESSURE REQUIRED AT 0 81 .40 PSI MAXIMUM PRESSURE UNBALANCE IN LOOPS 0 . 00 PSI MAXIMUM VELOCITY FROM 28 TO 68 19 .48 FPS SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 2 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 93 103 1 . 049 L 30 . 00 C=120 PT 19 .14 (103) Q 49 . 00 F=T, 2E F 9 . 00 PE -3 . 03 DR1 T 39 .00 0 .6829 PF 26 . 63 70 93 1 .442 L 12 . 00 C=120 PT 42 . 74 ( 93) Q 49 . 00 F=T F 5 .40 PE 0 . 00 BN1 T 17 .40 0. 1450 PF 2 . 52 PT 45 .26 ( 70) 95 105 1 . 049 L 30 . 00 C=120 PT 19.26 (105) Q 49 . 15 F=T, 2E F 9 . 00 PE -3 . 03 DR1 T 39 . 00 0.6869 PF 26 . 79 70 95 1 .442 L 10 . 00 C=120 PT 43 . 02 ( 95) Q 49 . 15 F=T F 5 .40 PE 0 . 00 BN2 T 15 .40 0 . 1458 PF 2 .25 30 70DQ 49 . 00 1 .442 L 1 .70 C=120 PT 45 . 27 ( 70) Q 98 . 15 F=T F 5 .40 PE 0 .74 NR1 T 7 . 10 0. 5242 PF 3 . 72 29 30 2 .635 L 12 .30 C=120 PT 49 . 73 ( 30) Q 98 .15 F=0 F 0. 00 PE 0. 00 NC1 T 12 .30 0. 0278 PF 0 .34 PT 50 . 07 ( 29) 94 104 1 . 049 L 30 .00 C=120 PT 19 .52 (104) Q 49.48 F=T, 2E F 9 . 00 PE -3 . 03 DR1 T 39 . 00 0 .6953 PF 27 . 12 68 94 1 .442 L 10 . 00 C=120 PT 43 . 61 ( 94) Q 49 .48 F=T F 5 .40 PE 0 . 00 BN2 T 15 .40 0 . 1476 PF 2 .27 PT 45 . 88 ( 68) 92 102 1 . 049 L 30 . 00 C=120 PT 19 .67 (102) Q 49.68 F=T, 2E F 9. 00 PE -3 . 03 DR1 T 39 .00 0 .7004 PF 27 .32 68 92 1.442 L 7 .50 C=120 PT 43 . 96 ( 92) Q 49.68 F=T F 5 .40 PE 0. 00 BN1 T 12 . 90 0.1487 PF 1 . 92 28 68DQ 49 .48 1 .442 L 1 . 70 C=120 PT 45 . 88 ( 68) Q 99 . 16 F=T F 5 .40 PE 0 . 74 NR1 T 7 . 10 0.5342 PF 3 .79 PT 50.41 ( 28) SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 3 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary • From To GPM IN Devices Ft PSI/Ft PSI 91 101 1. 049 L 30 . 00 C=120 PT 21 .32 (101) Q 51 . 71 F=T, 2E F 9 . 00 PE -3 . 03 DR1 T 39 . 00 0.7545 PF 29 .43 COMMENT: INCLUDES EQUIV LEN FOR 4 ' FLEXHEAD DROP 67 91 1.442 L 7 . 50 C=120 PT 47 . 72 ( 91) Q 51 .71 F=T F 5 .40 PE 0 . 00 BN1 T 12 . 90 0 . 1602 PF 2 . 07 27 67 1 .442 L 1.70 C=120 PT 49. 79 ( 67) Q 51 .71 F=T F 5.40 PE 0 .74 NR1 T 7 .10 0 .1602 PF 1 .14 PT 51 .67 ( 27) 28 29 2 .635 L 12 .30 C=120 PT 50 . 06 ( 29) Q 98 . 15 F=0 F 0 . 00 PE 0 . 00 NC1 T 12 .30 0 .0278 PF 0.34 27 28DQ 99 . 16 2 .635 L 12 .30 C=120 PT 50 .40 ( 28) Q 197 .31 F=0 F 0 . 00 PE 0. 00 . NC1 T 12 .30 0.1013 PF 1 . 25 26 27DQ 51 . 71 2 .635 L 12 . 30 C=120 PT 51.65 ( 27) Q 249 . 03 F=0 F 0. 00 PE 0. 00 NC1 T 12 .30 0 .1558 PF 1.92 66 26DQ -221 . 99 1 .442 L 1 . 70 C=120 PT 53 . 57 ( 26) Q 27 . 04 F=T F 5 . 40 PE -0.74 RN1 T 7 . 10 0.0483 PF 0 .34 86 66 1 .442 L 72 . 00 C=120 PT 53 .17 ( 66) Q 27 . 04 F=T/T F 10 . 80 PE 0 . 00 BL1 T 82 . 80 0 .0483 PF 4 . 00 46 86 1.442 L 2 . 30 C=120 PT 57 . 17 ( 86) Q 27 . 04 F=T F 5 .40 PE 1 . 00 RN2 T 7 . 70 0 . 0483 PF 0.37 45 46 2 .635 L 12 .30 C=120 PT 58.54 ( 46) Q 27. 04 F=0 F 0 . 00 PE 0 . 00 ' CM2 T 12 . 30 0 . 0026 PF 0. 03 44 45DQ 21 .92 2 .635 L 12 .30 C=120 PT 58 . 57 ( 45) Q 48 . 96 F=0 F 0 .00 PE 0. 00 CM2 T 12 .30 0.0077 PF 0 . 09 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 4 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 43 44DQ 17 . 07 2 .635 L 12 .30 C=120 PT 58 .66 ( 44) Q 66 . 02 F=0 F 0. 00 PE 0 . 00 CM2 T 12 .30 0 . 0134 PF 0 .16 42 43DQ 12 .26 2 . 635 L 61 .00 C=120 PT 58 . 82 ( 43) Q 78.29 F=2E F 8 .60 PE 0 . 00 CM2 T 69 .60 0 .0183 PF 1 .27 41 42DQ 11 .36 2 .635 L 12 .30 C=120 PT 60 . 09 ( 42) Q 89.65 F=0 F 0. 00 PE 0 . 00 CM2 T 12 . 30 0. 0235 PF 0.29 40 41DQ 8 . 70 2 .635 L 12 . 30 C=120 PT 60 .38 ( 41) Q 98 .35 F=0 F 0. 00 PE 0.00 CM2 T 12 . 30 0. 0279 PF 0 .34 39 40DQ 6 .12 2 .635 L 12 .30 C=120 PT 60 . 72 ( 40) Q 104 .47 F=0 F 0 . 00 PE 0 . 00 CM2 T 12 .30 0 .0312 PF 0 .38 38 39DQ 3 . 17 2 . 635 L 12 .30 C=120 PT 61 . 10 ( 39) . Q 107 . 64 F=0 F 0 . 00 PE 0. 00 CM2 T 12 .30 0 . 0330 PF 0.41 37 38DQ -3 . 17 2 .635 L 12 .30 C=120 PT 61. 51 ( 38) Q 104 .47 F=0 F 0. 00 PE 0. 00 CM2 T 12 .30 0. 0312 PF 0. 38 36 37DQ -6 . 12 2 .635 L 12 . 30 C=120 PT 61 . 89 ( 37) Q 98 .35 F=0 F 0 . 00 PE 0. 00 CM2 T 12 . 30 0 . 0279 PF 0.34 35 36DQ -8 . 70 2 .635 L 12 .30 C=120 PT 62 .23 ( 36) Q 89 .65 F=0 F 0 . 00 PE 0 . 00 CM2 T 12 .30 0 . 0235 PF 0 .29 34 35DQ -11 .36 2 .635 L 61. 00 C=120 PT 62 .52 ( 35) Q 78 .29 F=2E F 8 . 60 PE 0 . 00 CM2 T 69 .60 0.0183 PF 1 .27 9 34DQ -12 . 26 2 . 635 L 3 .30 C=120 PT 63 .79 ( 34) ' Q 66 . 02 F=0 F 0 . 00 PE 0 . 00 CM2 T 3 .30 0 .0134 PF 0 . 04 33 9 2 .635 L 9 . 00 C=120 PT 63 . 83 ( 9) Q 66 . 02 F=0 F 0 . 00 PE 0 . 00 CM2 T 9. 00 0. 0134 PP 0 . 12 PT 63 . 95 ( 33) SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 5 DOW AGROSCIENCES TI MRA #1 BLDG. C .15/LAB E O.H. GROUP 1 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary • From To GPM IN Devices Ft PSI/Ft PSI 25 26 2 .635 L 12 . 30 C=120 PT 53 .57 ( 26) Q 221 . 99 F=0 F 0 . 00 PE 0.00 CM3 T 12 .30 0.1259 PF 1 . 55 65 25DQ -200 .07 1.442 L 1 .70 C=120 PT 55 .12 ( 25) Q 21 . 92 F=T F 5.40 PE -0 . 74 RN1 T 7 .10 0 .0327 PF 0 .23 85 65 1 .442 L 72 . 00 C=120 PT 54 . 61 ( 65) Q 21 . 92 F=T/T F 10 . 80 PE 0 . 00 BL1 T 82 . 80 0.0327 PF 2 . 71 45 85 1.442 L 2 . 30 C=120 PT 57 .32 ( 85) Q 21 . 92 F=T F 5 .40 PE 1 .00 RN2 T 7 . 70 0 .0327 PF 0.25 PT 58 .57 ( 45) 24 25 2 . 635 L 12 .30 C=120 PT 55 . 12 ( 25) Q 200. 07 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 .30 0 .1039 PF 1.28 64 24DQ -183 . 00 1.442 L 1 .70 C=120 PT 56 .40 ( 24) Q 17 . 07 F=T F 5.40 PE -0 . 74 RN1 T 7 . 10 0.0206 PF 0 . 15 84 64 1 .442 L 72 . 00 C=120 PT 55 . 81 ( 64) Q 17 . 07 F=T/T F 10 .80 PE 0 . 00 BL1 T 82 . 80 0.0206 PF 1. 71 44 84 1.442 L 2 .30 C=120 PT 57 .52 ( 84) Q 17 . 07 F=T F 5 .40 PE 1 . 00 RN2 T 7 . 70 0.0206 PF 0 . 16 PT 58 .68 ( 44) 23 24 2 .635 L 12 .30 C=120 PT 56 . 39 ( 24) Q 183 .00 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 .30 0 .0881 PF 1 . 08 63 23DQ -170 . 74 1 .442 L 1 . 70 C=120 PT 57 .47 ( 23) Q 12 .26 F=T F 5 .40 PE -0. 74 " RN1 T 7 . 10 0. 0112 PF 0 .08 83 63 1 .442 L 72 . 00 C=120 PT 56 . 81 ( 63) Q 12 .26 F=T/T F 10 .80 PE 0 . 00 BL1 T 82 . 80 0.0112 PF 0 . 93 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 6 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 43 83 1 .442 L 2 . 30 C=120 PT 57 . 74 ( 83) Q 12 .26 F=T F 5.40 PE 1 .00 RN2 T 7 . 70 0.0112 PF 0 . 09 PT 58 . 83 ( 43) 22 23 2 .635 L 12 .30 C=120 PT 57 .48 ( 23) Q 170.74 F=0 F 0 . 00 PE 0 .00 CM3 T 12 .30 0. 0775 PF 0 .95 62 22DQ -159 . 38 1 .442 L 1 . 70 C=120 PT 58 .43 ( 22) Q 11 . 36 F=T F 5 .40 PE -0 .74 RN1 T 7 . 10 0 . 0097 PF 0 . 07 82 62 1 .442 L 120 . 00 C=120 PT 57 . 76 ( 62) Q 11 .36 F=T/T F 10 .80 PE 0 . 00 BL1 T 130 . 80 0.0097 PF 1 .27 42 82 1 .442 L 2 .30 C=120 PT 59 . 03 ( 82) Q 11. 36 F=T F 5 .40 PE 1 . 00 RN2 T 7 .70 0 .0097 PF 0 . 07 PT 60 . 10 ( 42) 21 22 2 .635 L 12 .30 C=120 PT 58.43 ( 22) Q 159.38 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 . 30 0. 0682 PF 0. 84 61 21DQ -150 .68 1 .442 L 1 . 70 C=120 PT 59.27 ( 21) Q 8 . 70 F=T F 5.40 PE -0 . 74 RN1 T 7 . 10 0.0059 PF 0 . 04 81 61 1.442 L 120 . 00 C=120 PT 58 .57 ( 61) Q 8 . 70 F=T/T F 10 .80 PE 0 . 00 BL1 T 130 . 80 0. 0059 PF 0 . 77 41 81 1 .442 L 2 .30 C=120 PT 59.34 ( 81) Q 8 .70 F=T F 5 .40 PE 1. 00 RN2 T 7 . 70 0 . 0059 PF 0. 05 PT 60. 39 ( 41) 20 21 2 .635 L 12 . 30 C=120 PT 59.27 ( 21) Q 150 . 68 F=0 F 0. 00 PE 0 . 00 CM3 T 12 . 30 0. 0615 PF 0 .76 60 20DQ -144 .56 1 .442 L 1 .70 C=120 PT 60 . 03 ( 20) Q 6 . 12 F=T F 5 .40 PE -0 . 74 RN1 T 7 . 10 0. 0031 PF 0 . 02 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 7 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 . Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 80 60 1 .442 L 120 . 00 C=120 PT 59 . 31 ( 60) Q 6 . 12 F=T/T F 10. 80 PE 0 . 00 BL1 T 130 . 80 0. 0031 PF 0 .41 40 80 1 .442 L 2 .30 C=120 PT 59 . 72 ( 80) Q 6 . 12 F=T F 5 .40 PE 1. 00 RN2 T 7 .70 0 .0031 PF 0. 02 PT 60. 74 ( 40) 19 20 2 .635 L 12 .30 C=120 PT 60 . 03 ( 20) Q 144 . 56 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 .30 0. 0570 PF 0 . 70 59 19DQ -141.39 1 .442 L 1. 70 C=120 PT 60. 73 ( 19) Q 3 . 17 F=T F 5.40 PE -0 . 74 RN1 T 7 . 10 0 . 0009 PF 0 . 01 79 59 1 .442 L 120. 00 C=120 PT 60 . 00 ( 59) Q 3 . 17 F=T/T F 10 . 80 PE 0. 00 BL1 T 130. 80 0. 0009 PF 0 . 12 • 39 79 1.442 L 2 .30 C=120 PT 60 . 12 ( 79) Q 3 . 17 F=T F 5 .40 PE 1 . 00 RN2 T 7. 70 0 . 0009 PF 0 . 01 PT 61 . 13 ( 39) 78 38 1 .442 L 2 .30 C=120 PT 61 .53 ( 38) Q 3 . 17 F=T F 5. 40 PE -1 .00 RN2 T 7 .70 0.0009 PF 0. 01 58 78 1.442 L 120. 00 C=120 PT 60 .54 ( 78) Q 3 . 17 F=T/T F 10. 80 PE 0 . 00 BL1 T 130. 80 0. 0009 PF 0. 12 18 58 1.442 L 1 . 70 C=120 PT 60 . 66 ( 58) Q 3 . 17 F=T F 5 .40 PE 0. 74 RN1 T 7. 10 0 .0009 PF 0. 01 PT 61 .41 ( 18) 77 37 1.442 L 2 .30 C=120 PT 61 . 91 ( 37) Q 6 . 12 F=T F 5 .40 PE -1 . 00 RN2 T 7 . 70 0 . 0031 PF 0 . 02 57 77 1.442 L 120. 00 C=120 PT 60 . 93 ( 77) Q 6 . 12 F=T/T F 10. 80 PE 0 . 00 BL1 T 130.80 0 .0031 PF 0.41 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 8 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 S Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 17 57 1 .442 L 1 . 70 C=120 PT 61 . 34 ( 57) Q 6 . 12 F=T F 5 .40 PE 0 . 74 RN1 T 7 . 10 0.0031 PF 0 . 02 PT 62 .10 ( 17) 76 36 1 .442 L 2 .30 C=120 PT 62 .25 ( 36) Q 8 . 70 F=T F 5 .40 PE -1 .00 RN2 T 7. 70 0. 0059 PF 0 . 05 56 76 1 .442 L 120. 00 C=120 PT 61 . 30 ( 76) Q 8. 70 F=T/T F 10. 80 PE 0 . 00 BL1 T 130 .80 0 .0059 PF 0 .77 16 56 1.442 L 1 .70 C=120 PT 62 . 07 ( 56) Q 8 . 70 F=T F 5 .40 PE 0. 74 RN1 T 7 .10 0 .0059 PF 0 . 04 PT 62 . 85 ( 16) 75 35 1.442 L 2 .30 C=120 PT 62 . 54 ( 35) Q 11 .36 F=T F 5 .40 PE -1. 00 RN2 T 7 .70 0.0097 PF 0. 07 • 55 75 1.442 L 120 . 00 C=120 PT 61 . 61 ( 75) Q 11 .36 F=T/T F 10 . 80 PE 0 . 00 BL1 T 130 . 80 0. 0097 PF 1 .27 15 55 1.442 L 1 . 70 C=120 PT 62 .88 ( 55) Q 11 .36 F=T F 5 .40 PE 0 .74 RN1 T 7 . 10 0. 0097 PF 0 . 07 PT 63 .69 ( 15) 74 34 1 .442 L 2 . 30 C=120 PT 63 . 82 ( 34) Q 12 .26 F=T F 5.40 PE -1 . 00 RN2 T 7 . 70 0. 0112 PF 0 . 09 54 74 1 .442 L 72 . 00 C=120 PT 62 . 91 ( 74) Q 12 .26 F=T/T F 10.80 PE 0 . 00 BL1 T 82 . 80 0.0112 PF 0. 93 14 54 1.442 L 1 . 70 C=120 PT 63 . 84 ( 54) Q 12 .26 F=T F 5 .40 PE 0 .74 RN1 T 7 .10 0.0112 PF 0 . 08 PT 64 .66 ( 14) 73 33 1 .442 L 2 .30 C=120 PT 63 . 98 ( 33) Q 17 . 07 F=T F 5.40 PE -1 . 00 RN2 T 7. 70 0. 0206 PF 0 . 16 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 9 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 • Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary • From To GPM IN Devices Ft PSI/Ft PSI 53 73 1.442 L 72 . 00 C=120 PT 63 . 14 ( 73) Q 17. 07 F=T/T F 10 . 80 PE 0 . 00 BL1 T 82 . 80 0. 0206 PF 1 . 71 13 53 1 .442 L 1 . 70 C=120 PT 64 . 85 ( 53) Q 17 . 07 F=T F 5 .40 PE 0 . 74 RN1 T 7. 10 0. 0206 PF 0. 15 PT 65. 74 ( 13) 32 33 2 . 635 L 12 . 30 C=120 PT 63 . 98 ( 33) Q 48 . 96 F=0 F 0 . 00 PE 0. 00 CM2 T 12 .30 0. 0077 PF 0. 09 72 32DQ -27 . 04 1.442 L 2 .30 C=120 PT 64 .07 ( 32) Q 21 . 92 F=T F 5.40 PE -1 . 00 RN2 T 7 .70 0. 0327 PF 0 .25 52 72 1 .442 L 72 . 00 C=120 PT 63 . 32 ( 72) Q 21 . 92 F=T/T F 10 .80 PE 0 . 00 BL1 T 82 .80 0 .0327 PF 2 . 71 • 12 52 1.442 L 1 . 70 C=120 PT 66 . 03 ( 52) Q 21 . 92 F=T F 5 .40 PE 0 . 74 RN1 T 7 . 10 0 .0327 PF 0.23 PT 67 . 00 ( 12) 31 32 2 .635 L 12 .30 C=120 PT 64 . 08 ( 32) Q 27 . 04 F=0 F 0 . 00 PE 0 . 00 CM2 T 12 .30 0.0026 PF 0 . 03 71 31 1.442 L 2 .30 C=120 PT 64 . 11 ( 31) Q 27 .04 F=T F 5 .40 PE -1.00 RN2 T 7 . 70 0 . 0483 PF 0 .37 51 71 1 .442 L 72 . 00 C=120 PT 63 .48 ( 71) Q 27 . 04 F=T/T F 10 . 80 PE 0. 00 BL1 T 82 . 80 0. 0483 PF 4 . 00 11 51 1 .442 L 1 .70 C=120 PT 67 .48 ( 51) Q 27 . 04 F=T F 5 .40 PE 0 .74 RN1 T 7 . 10 0.0483 PF 0 .34 • PT 68 .56 ( 11) 18 19 2 .635 L 12 .30 C=120 PT 60 . 73 ( 19) Q 141 .39 F=0 F 0. 00 PE 0. 00 CM3 T 12 .30 0.0547 PF 0 .67 SUBMITTAL SERIAL NO:4126HY1 01-05-2011 PAGE 10 DOW AGROSCIENCES TI MRA #1 BLDG. C . 15/LAB E O.H. GROUP 1 r Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary • From To GPM IN Devices Ft PSI/Ft PSI 17 18DQ 3 . 17 2 .635 L 12 .30 C=120 PT 61.40 ( 18) Q 144 . 56 F=0 F 0 . 00 PE 0. 00 CM3 T 12 .30 0.0570 PF 0 .70 16 17DQ 6 .12 2 .635 L 12 .30 C=120 PT 62 .10 ( 17) Q 150.68 F=0 F 0. 00 PE 0 . 00 CM3 T 12 .30 0. 0615 PF 0 . 76 15 16DQ 8 . 70 2 . 635 L 12 . 30 C=120 PT 62 . 86 ( 16) Q 159 . 38 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 .30 0 . 0682 PF 0 . 84 14 15DQ 11 . 36 2 . 635 L 12 .30 C=120 PT 63 . 70 ( 15) Q 170 . 74 F=0 F 0 . 00 PE 0 . 00 CM3 T 12 .30 0 .0775 PF 0 . 95 13 14DQ 12 .26 2 .635 L 12 .30 C=120 PT 64 .65 ( 14) Q 183 . 00 F=0 F 0 .00 PE 0. 00 CM3 T 12 .30 0 .0881 PF 1 . 08 12 13DQ 17 . 07 2 .635 L 12 .30 C=120 PT 65.73 ( 13) • Q 200 . 07 F=0 F 0. 00 PE 0 . 00 CM3 T 12 . 30 0 . 1039 PF 1 . 28 11 12DQ 21 .92 2 .635 L 12 . 30 C=120 PT 67 . 01 ( 12) Q 221 . 99 F=0 F 0. 00 PE 0 . 00 CM3 T 12 . 30 0. 1259 PF 1 .55 7 11DQ 27 .04 2 .635 L 13 . 00 C=120 PT 68.56 ( 11) Q 249 . 03 F=2E F 8 . 60 PE 0.00 FM1 T 21 . 60 0. 1558 PF 3 . 37 1 7 4 .026 L 9 .20 C=120 PT 71 .93 ( 7) Q 249 . 03 F=0 F 0 .00 PE 3 .99 FR2 T 9 . 20 0.0198 PF 0. 18 0 1 4 . 026 L 4 . 00 C=120 PT 76 . 10 ( 1) Q 249 . 03 F=DDC F 0.00 PE 1. 73 FR1 T 4 . 00 0.0198 PF 0 . 08 4" AMES 300a DBL. CHECK DET. ASSY. 3 .49 COMMENT: INCLUDES FRICTION LOSS FOR 4 INCH DDCVA • PT 81 .40 ( 0) • W s > r • DOW AGROSCIENCES TI MRA #1 Sigma dynamics Corporation7700 Supply/ Demand Graph 250 240 I 230 - Margin Pressure 20.63 PSI 220 Flow 513.34 GPM 210 200 190 180 170 — 180 150 ui 140 LL 130 i 120 a 110 a. 100 0 .•••••••••••,...` 90 `"—'....'�. 80 0 0 ....''"—mw —S, 70 N0 80 i 50— 40 r 30 o 20 Q 10 N 185 0100 200 300 400 500 600 700 800 900 1000 Water Flow(GPM) System Demand.. Water Supply.. Sprinkler Demand 81.40 PSI @ 249.03 GPM Static 105.00 PSI Additional Flows 0.00 GPM Residual 76.00 PSI @ 852.00 GPM Hose at Source 0.00 GPM Elevation 0.00 PSI Total Demand 81.40 PSI @ 249.03 GPM