Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (4)
. • a t 52o/9-DO/,35 /4037 ct t%ecexk Fre_ RECEIVED OCT 282019 CITY OF TIGARD BUILDING DIVISION Co te 'r r• Pfl n arli TEC - • • ES Making a Daily Difference Product Data Submittal Booklet Oregon State Bar FACP Replacement Fire Alarm System Project #: 302-FN-J0559 Submittal Date: 10/25/2019 Electronic Security Project Manager: Ron Pulioff Project Designer: Bryan Duffel Fire Alarm & Life Safety Building Automation 503-228-8522 I www.conver2int.cotn EDWARDS Catalog► Small Building Fire alarm Solutions HcffitIWAR LIFE SAFETY v INCIDENT MANAGEMENT Intelligent Fire s. Alarm Systems 1064, i01000 S'MI'{ FDNY Q:r COA 6227 (0"� IY� 7165-1657 0244 S3000 Overview Features EDWARDS brand intelligent life safety systems offer the power • Auto-programming speeds installation time of high-end intelligent processing in configurations that deliver • Supports Signature Series intelligent modules and detectors uncomplicated solutions for small to mid-sized applications.With intelligent detection,electronic addressing,automatic device • Combines the Signature intelligent releasing module with mapping, optional Ethernet®connectivity, and a full line of easily- Signature muttisensor detectors for reliable fire suppression configured option cards and modules,these flexible systems offer • Form C contacts for alarm and trouble,Form A for supervisory versatility that benefits building owners and contractors alike. • Electronic addressing with automatic device mapping The i064 provides one Class A or Class B intelligent device loop • Optional Ethernet port for diagnostics, programming and a that supports up to 64 device addresses,and two Class B Notifi- variety of system reports cation Appliance Circuits(NAGS).Optional Class A device wiring is available with the use of a module. • Two programmable switches with LEDs and custom labeling The i01000 provides one Class A or Class B intelligent device ' Supports Genesis horn silence over two wires, and UL loop that supports up to 250 device addresses. Loop controller 1971-compliant strobe synchronization modules may be added in combination to expand total system • Class B or Class A wiring capacity in 250-point increments to up to 1,000 device addresses. • Ground fault detection by module The i01000 panel includes four NACs that may be wired for either Class A or Class B operation. • Supports up to eight serial annunciators, (LCD, LED-only,and graphic interface) The RZI16-2 module adds even more capacity to i0 installations • Can use existing wiring for most retrofit applications by adding up to 16 conventional device circuits and two additional notification appliance circuits.This makes them an ideal retrofit • Upload/download remotely or locally solution that can accommodate new intelligent detectors,as well • Two-level maintenance alert reporting as existing conventional devices. • Pre-alarm and alarm verification by point iO Series supports a wide range of high-end features, including: • Adjustable detector sensitivity • Signature Series intelligent modules, detectors,and bases • 4 x 20 character backlit LCD display • R-Series remote annunciators • Optional earthquake hardening: seismic Importance Factor 1.5 • SIGA-REL Releasing Modules • Standalone operation • Fully integrated CO detection using Signature Series detec- tors with or without audible signaling • Transmission test frequency by hour Page 1 of 8 E85001 -01 35 Issue 1.1 Application EDWARDS i0 Series life safety systems are powerful intelligent solu- Flexibility built right in tions for small to mid-sized buildings.Advanced intelligent technol- Two fully-programmable front panel switch/LED combinations pro- ogy delivers the benefits of flexible system installation,while clean vide an added measure of flexibility.Their slide-in labels take the and easy-to-operate user interlaces make panel operation and mystery out of custom applications,and present a clean finished system maintenance quick and intuitive. appearance. The smart choice Perfect for retrofits Signature Series electronic addressing eliminates the tedium of EDWARDS i0 Series control panels are particularly well-suited to setting dipswitches, and automatic device mapping ensures that retrofit applications.All connections are made over standard wiring each device resides on the system at its correct location. Mean- -no shielded cable required.This means that in most situations while, innovative programming allows the designer to customize existing wiring can be used to upgrade a legacy control panel to the system to precisely suit the needs of the building owner. . i0 technology without the expense or disruption of rewiring the en- tire building. i0 control panels also support the ingenious RZI16-2 Reliability you can count on Zone Module, which adds up to 16 conventional circuits and two The inherent fault-tolerant characteristics of Analog/Addressable NACs.This combination easily accommodates new intelligent Technology boosts the reliability of EDWARDS fire alarm systems. detection alongside existing conventional circuits, making it an When combined with iO Series smoke and heat detectors,these superior solution in the retrofit market. systems deliver a level of dependability not previously available for small to mid-sized applications.All EDWARDS systems are built to Signals with a difference exacting reliability benchmarks and meet international standards iO system NACs are configurable to fully support the advanced for quality, in addition to agency listings for dependability. signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances.These devices offer precision synchro- Clear-cut remote annunciation nization of strobes to UL 1971 standards. For Genesis devices, Remote annunciation is a strong suit of the i0 Series fire alarm enabling this feature allows horns to be silenced while strobes on systems. Up to eight annunciators can be installed on a single the same two-wire circuit continue to flash until the panel is reset. system.Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation,as well as corn- A complete line of accessories mon control capabilities. i0 control panels also supports graphic i0 Series life safety systems are supported by a complete line of annunciation with optional RA Graphic Annunciator interface mod- analog/addressable detectors, modules and related equipment. ules. Each interface provides common control and 32 LEDs. Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions EDWARDS iO Series life safety systems are simple to set up,yet {1) Ir02 I (2) 63) 67 offer advanced programming features that put these small building 03 .4-07 panels into a class of their own.The auto programming feature • •0 • •0 '0 quickly gets the panel operational using factory default settings. i O )O Basic zone and point settings can be programmed through the • O O O front panel interface,so the system is up and running in no time. I O For more advanced system configuration and correlation groups Di i • 04 O 0 programming, iO Series systems interface to a PC running com- . 4. • ® _ e 1 0 I 06 .O 0 patible i0-CU software.This option offers full system configuration 1 in the familiar Windows®operating environment.Connection is • a • made to a laptop through the panel's optional RS-232 communi- • cations port, which can also be used to connect a system printer. ' -= D6 Among the'many innovative features of iO Series control panels tTh0ei t' is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to Panel dimensions,in(cm) download to the panel from the i0-CU, or upload and view system Model Dr 02 D3 D4 D5' D6 D7 08 D9 reports using the i0-CU. iO1000 28.0 3.85 9.0 22.0 15.75 10.25 4.4 28.2 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (11.1) (71.6) (6.8) Available system reports include: 1064 21.5 3.85 7.5 15.5 14.25 10.25 4.5 21.7 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (11.4) (55.1) (6.8) • Correlation groups • Device details 'Add 1-1/2 In.(3.81 cm)to D1 and D5 dimensions for trim kit.The trim kit • Device maintenance • History provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. • Internal status • System configuration • System status • Walk test • Dialer • CO runtime Page 2 of 8 E85001 -0135 Issue 1.1 System Layout ' iol000 Any combination of two single-or dual Signature loop modules „I _ Stai card Loop:250 points one expansion slot) 10-SDC2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop (one expansion slot) • _ '' f r d , 7—'---14.4,1-7,,sy,2 II ,J.,,t.'t. iD-SDC11 ipander Loop:250 points(one expansion slat) i0-SDC2 Expander,Loop 2 of 2:250 points ,Up to 20,000 feet of wiring per loop f FIRE. FIRE' FIRE nnE -.• " f IRE FIRE Flnr FIRE 1IRl :i Nlitr Four Class 13 or two optional Class A NACs 7- = Four Class 8 or two optional Class A NACs Optional 10 A or 6.5 A Booster } .t is " Ethernet(SA-ETH) il DACT/Dialer(SA-DACT) is Up to eight ' 6. ., unciators RS-232(SA-232) Sixteen Conventional IDCs, Relays:Two Form C,one Form A two additional NACs with RZI16-2 module Each iO1000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. 101000 loops support 125 detectors and 125 modules. Palle Layout 1064 2 Hie 1i �—` 6 u i.- -e ._3r I. ''' tr iiii or■ Cp onEr Loop supports up to 64 intelligent devices of any type. ..1ry� "al- •`'8 _ [ ,o �No . J Up to 20,000 feet of wiring. 6M . 1-- 12 tl:, F x....;.� I— nge, O E FIRE FIRE ' I ' Two Class El or Iwo optional Class A NACs 1 ; Optional 10 A or 6.5 A Booster Power Supply o -: ` .41 Up to eight -•: . nunciators E2 2 Main AC wiring block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA-ETH) _ 4 Dialer card connection(J8) DACT/Dialer(SA-DACT) I ?] --} 5 Ethernet card connector(J1) 6 Main circuit board RS-232(SA-232) 7 Panel backbox enclosure Relays:Two Form C,one Form A B Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) Each i064 panel ships with one Signature loop controller that sup- 11 Tie wrap mounts ports 64 devices of any type.This panel's device capacity cannot 12 Sby connector(J6) be expanded. 13 Standby b bats r atteries Page 3 of 8 . E85001-0135 Issue 1.1 Wiring & Configuration Signature device loop Auxiliary&smoke power outputs(TB3) The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power TB3 capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary O—J— circuit is supervised for opens,shorts, and grounds. equipment such as remote annunciators and two (1) NO wire smoke detectors. Aux 2 can be software NC Circuit i01000 064 selected to operate continuously.The circuit is specifications Device loops One Class B or A One Class B or A loop, supervised for shorts and grounds. supportingfr (2) 0SNO loop, 125 supporting 64 devices of Circuit specifications "" detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range four loops. _ Resettable circuit 24 VDC nominal at 500 mA (3) —INC Communication Maximum 20 V peak-to-peak (Aux power 2) NO line voltage 0—3'Continuous circuit 24 VDC nominal at 500 mA. Circuit current 0.5 A max (Aux power 1) Use this circuit for powering 0 Circuit . 660 total,0.5 pF,max two-wire smoke detectors. impedance (4) 0 Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux ICJ 1 and 2 will reduce the total available NAG power by that 0 Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using a SIGA-CC1 S or SIGA-MCC1S module (1)Trouble and Genesis or Enhanced Integrity notification ap- Alarm,trouble,and supervisory relay(TB3) pliances. The trouble relay is normally-open, held closed, (2)AlarSupm Class Bwking Class Awiring and opens on any trouble event or when the panel is de-energized.The supervisory relay is (4)Smoke/Aux SLC A ,& D ash,. SLC A ;19 normally-open,and closes on any supervisory m m + --� event.The alarm relay changes over on any SLC B ��( �� SLC B m • ONE m - alarm event. Loop Loop Loop carddevice device Loop rd °Ba Lna p dark. Relay specifications Alarm_ l Trouble Supervisory Type Form C Form A Notification appliance circuits(TB2) Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive i01000 control panels come equipped with four notification ap- Relay circuits can only be connected to power-limited sources. pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous,temporal, synchronized, and coded output. Annunciator loop(TB4) Specifications i i01000 ! i064 The control panel provides a connection for up to eight serially Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. with SA-CLA module Voltage 24 VFWR Circuit specifications • Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class B(Style'Y)or Class A(Style Z) per circuit at 120/230 per circuit at 120/230 Circuit voltage 2.55 V VAC 60 Hz. VAC 60 Hz. Circuit current 30 mA max 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feet per circuit at 230 VAC per circuit at 230 VAC impedance 50 Hz. 50 Hz. Impedance 26 0 total,0.35 pF max Class B Class A EOLR 15 K 4,1/2 VV Channel 1 Channel 2 Channel 1 Channel 2 Synchronization Supported system-wide + — + — + — + — • ® & m ® TIM Q ® ® QTe4 Class 6 wiring Class A wiring Nnc1- Naci- Annunciator Annunciator 0 NAC1. allmlia ' 0 N.C�, + Q + a 0CH1(+)IN 0CH1(+)IN . EOLR &CHI(-)IN 1&CH1(-)IN 0 MU. a®aillaw 0 ::2.,; c + i + 4 Nnca - CH2 ))IN CH2(+)IN TB2 TEI2 � !�o�8��8tr + CH2(-)IN EOLR O rm �� /sill/t1 + Tat Tee Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. Page 4 of 8 E85001-0135 . :.c. Issue 1.1 Option Cards EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone Interface Module of modules and related equipment that enhance performance .. and extend system capabilities.Option cards plug directly into the control panel main circuit board or are connected to it with a - mi- ribbon cable. After installation,terminals remain accessible.The .e lot i_ ) cabinet provides ample room for wire routing, keeping wiring neat I I "v at all times. I '�� -:.Iri Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an The iO-SDC1 is a single loop controller card that can be used with addressable device that provides connections for sixteen Class B the i064 as a replacement for the standard 64-point loop, or with Initiating Device Circuits and two Class B Supervised Output the i01000 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for The iO-SDC2 is a 500-point dual loop controller card for the several device types. i01000 that provides two SLC circuits,each with 125 detector It requires 18 consecutive addresses on the Signaling Line Circuit addresses and 125 module addresses. (SLC).Addresses are assigned electronically.There are no address 4 switches to set. Specifications i0-SDC1 iO-SDC2 pit. Device Addresses i i01000:one loop,250 01000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that are device addresses 500 device addresses used to select the Alarm or Supervisory default device type for 1064:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output Operating Voltage 24 VDC device type. Device types other than the default are accomplished Operating Current Standby:55 mA Standby:45 mA through programming. (fully loaded loop) Alarm:80 mA Alarm:70 mA Note:These ratings do not include the use of two-wire smoke modules. RZI16-2 Specifications Communication Line Max.20.6 V peak-to-peak Voltage Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Terminal Rating 12 to 18 AWG(0.75 to 2.5 mm2) Alarm Current 1000 mA Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC Max total loop 66 0 24V/Aux maximum: 26.4 VDC resistance NAC1,NAC2 nominal: 24 VDC Max total loop 0.5 pF Current capacitance Standby current Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit isolator bases and modules) Standby current for Ground Fault 0 to 5 k0 3.9 k EOL(Canada) 5.7 rnA/circuit Impedance Alarm current Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 fl per wire SA-ETH Ethernet Interface Card resistance SA-ETH wiring The SA-ETH card provides a Initiating device circuits To network �� conned on standard 10/100 Base T Ether- Quantity 16 Network cable .�� net network connection for EOL resistor 4.7 kt?(U.S.);3.9 kft Canada Vconnecting to an intranet,a local Zone voltage 22.78 V for 4.7 k0(U.S.) network,or the Internet.The 22.08 V for 3.9 k0(Canada) + card can be used to download Alarm current 31.1 mA/channel at nominal voltage 6 ® ca beprogrammingedofrom Alarm impedance range <680 fl 9p 9 Trouble impedance range >5.55 k° the i0-CU to the panel. Supervised output circuits The Ethernet card is installed on EOL resistor 15 k0 a the plastic assembly and con- Short it 2 o Short circuit detection <2.6 k4 con- nects to the main circuit board Open circuit detection >61.9 k Ethernet card via a ribbon cable. tt Contact ratings 24 VDC at 2.5 A(5 A for two NACs) SA-ETH specificationsCompatible cabinets MFC(A),iO1000,APS Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Page 5 of 8 E85001-0135 Issue 1.1 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- SA-232 wiring panel and the central station over a telephone line system. It terrace with i0 panels. It can be used for DND(black eke) TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel —RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also network.The dialer is capable of single,dual, or split reporting can be used for connecting a computer g®®®® fA of events to two different account and telephone numbers.The to download a configuration program 0 (i modem feature of the SA-DACT can also be used for uploading from the i0-CU to the control panel. 0 0 and downloading panel configuration,history,and current status The RS-232 card is installed on the plas- to a PC running the i0 CU. tic assembly and connects to the main circuit board via a ribbon SA-DACT Phone line 2 wiring 9 cable. Phone line 1 ph wall phone Jack _, SA-232 specifications Phone cables Operating voltage Standard EIA-232 (supplied) 1' 1. RJ31 Jacks V n_J Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) ILtI The dialer phone lines connect to Operating environment connectors on the dialer's main Temperature 32 to 120°F(0 to 49°C) ''..- .' Humidity 0 to 93%RH,noncondensing at 90°F(32°C) '-n• circuit •board.Phone line 1 connects ME Ma . , to connector J4 and phone line 2 hille connects to connector J1. - 1i ••4 _ - SA-CLA Class A Module(1064 only) o❑❑ 00(�p -• rr°�� The SA-CLA card provides Class A capability for NAC wiring. o❑❑LiLJ• °1._1'.1 Its terminal block provides the wiring connection for NAC return 10De Bs=moo wiring.The card is required for annunciator,Class A wiring even oas though this wiring does not return to the SA-CLA card.The SA- The SA-DACT queues mes- CLA is compatible with i064 control panels only.i01000 panels sages and transmits them based on priority(alarm,supervisory, are Class A Ready.The SA-CLA is installed directly to the control trouble, and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 VFWR the main circuit board via a ribbon cable. Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz SA-DACT specifications 2.5 A max per circuit Phone line type One or two loop-start lines on a public, Circuit impedance 26 ohms,0.35uF switched network Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Phone line connector RJ-31/38X(C31/38X) Operating environment Communication formats Contact ID(SIA DC-05) Temperature 32 to 120°F(0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F(0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Compatible DACRs >--<-.mom K° °' D16L-i0 LED Display Expander(101000 only) Receiver Models Formats The D16L-i0 LED Display Expanders provide LED annunciation for Ademco 685 Contact ID up to 16 zones.It provides two LEDs for each zone.Two D16L-i0 FBII CP220 Contact ID LED display expanders can be installed in each i01000 panel. Osbome-Hoffman OH 2000 Contact ID Bosch D6600 Contact ID (3) (4) Silent Knight 9800 Contact ID (1) Pi i IRiMil (1) stl 7 (1)LED 1 Sur-Gard SG-MLR1,MLR2 Contact ID (2) O,= �) will= (2)LED 2 1- 1= (3)LED Expander 1 41.1..1 0_ (4)LED Expander 2 {Ipmum {Iiums (5)Alarm/non-alarm kilt moms and trouble zone LEDs 11•1111111 MINIM ilium olimm i1___1- {.11t7'xr1 q1.... riles :ilk 012one 32 Page 6 of 8 E85001-0135 Issue 1.1 • Specifications 11064 iO1000 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop:124 Notification appliance 2 Class B(Style`I,Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the iO64 and 1O1000 Series Compatibility List(P/N 3102353-EN) Loop circuit Maximum loop resistance:66 0 Maximum loop capacitance:0.5 pF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the iO64 control panel cabinet and two 18 All batteries will fit in the iO1000 control panel cabinet.If larger batteries are required,use an EDWARDS battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38)) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESALO1 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1B Ground fault impedance 0 to 5 k0 - Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisorycontact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) Page 7 of 8 - E85001-0135 Issue 1.1 '".� Ordering Information " - WAR D S part Description 101000 Fire Alarm Systems LIFE SAFETY&INCIDENT MANAGEMENT 101000G Four loop system with one 250-point loop installed. 110v,gray door. IO1000G-2 Four loop system with one 250-point loop installed.230v,gray door. IO1000G-2-PG Four loop system with one 250-point loop installed.230v,gray door, Portuguese. Contact us... IO1000G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. Email: edwards.fire@fs.utc.com 101000G-CA Four loop system,one 250-point loop installed.110v,gray door,LED strips,Canada, Web: Edwards-fire,com 101000GD Four loop system,one 250-point loop installed.110v,gray door,with dialer. 101000E-F Four loop system,one 250-point loop. 110v,gray door,LED strips,French Canada. EDWARDS is a UTC brand. 101000G-PG Four bop system with one 250-point loop installed. 110v,gray door,Portuguese. 1016 Corporate Park Drive 101000G-SP Four loop system with one 250-point loop installed. 110v,gray door,Spanish. Mebane,NC 27302 IO1000R Four loop system with one 250-point loop installed. 110v,red door. 101000R-2 Four loop system with one 250-point loop installed.230v,red door. ©2016 United Technologies Corporation. 101000RD Four loop system,one 250-point loop installed.110v,red door,with dialer. All rights reserved. SA-TRIM2 101000 Flush mount trim,black. 1064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v,gray door. 1064G-2 One loop system with one 64-point loop installed.230v,gray door. 1064G-2-PG One loop system with one.64-point loop installed.230v,gray door,Portuguese. I064G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. --0•1064GD One loop system,one 64-point loop installed. 110v,gray door,with dialer. I064GL One loop system,one 64-point loop installed. 110v,gray door,English Canada. 1064GL-F One loop system,one 64-point loop installed. 110v,gray door,French Canada. • 1064G-PG One loop system with one 64-point loop installed.110v,gray door,Portuguese. 1064G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. 1064R One loop system with one 64-point loop installed.110v,red door. 1064R-2 One loop system with one 64-point loop installed.230v,red door. 1064RD One loop system,one 64-point loop installed. 110v,red door,with dialer. SA-TRIM1 i064 Flush mount trim,black Option Cards i0-SDC1 Expansion module,one 250-device loop. 10-SDC2 Expansion module,two 250-device loops,500 devices total.For i01000 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Includes bracket. SA-DACT Dual Line Dialer/Modem,supports Contact 1D,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs.Mounts in cabinet on main board.i064 systems only. D16L-iO-2 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32.For iO1000 only. D16L-iO-1 LED Annunciator module,16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16.For i01000 only. D8RY-iO-2 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For i01000 only. D8RY-iO-1 Canada only:LED Annunciator module,two LEDs per zone,16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For iO1000 only. Accessories ?� a rc g t,a € {situp .., . CTM City Tie Module.2-gang.Connection to a local energy lire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5"-red. SIGA-REL Releasing Module PT-1 S System Printer BC-1 Battery Cabinet. 14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 R Battery Cabinet-Red. 14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for i0 series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools i0-CU 10 Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Page 8 of 8 E85001 -0135 Issue 1.1 4 EDWARDS Catalog► Annunciation E 3 WARDS LIFE SAFETY INCIDENT MANAGEMENT A - Series Remote ors Annunciators RLCD, RLCD-C, RLED, RLED-C •, t- RLED24, GCI . _ . FDNY �C ® C0A6020 7120-1657: COA 6087 0254 53424 Overview Features EDWARDS R-Series Annunciators are high-performance remote • LCD models feature large 4 x 20 character backlit LCD display annunciators that provide status indication and common controls • LED models provide 16 pairs of LEDs for zone annunciation for compatible fire alarm control panels, including i0-Series small analog fire alarm systems.This family of annunciators offers LCD • Available expander extends capability with 24 pairs of LEDs or LED annunciation. Models are available with and without corn- • Up to two expanders may be wired to each annunciator mon controls. • Status LEDs and internal buzzer standard on all models There are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- • Common controls available for LED and LCD display models ciator.The expander includes 24 pairs of LEDs that extend the • Available keyswitch for disabling common controls capabilities of any of the annunciators. • Standard 4-inch square electrical box mounting All annunciator models include status LEDs and an internal buzzer. • Class or B Class A RS485 wiringstandard Two models have an LCD text display,and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, • One-,two-, and three-position enclosures available four by twenty character per line,super-twist liquid crystal display. • Graphic Annunciator interface, includes common control, indi- R-Series annunciators and expanders are mounted on a standard cators and 32 LEDS 4-inch square electrical box, using the included mounting ring. • No programing required, set the address and unit receives all They can also be surface mounted in locking steel enclosures. information from panel Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of 4 I , E85005-0128 - - r Issue 1 , ., Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. FACP """"a" Annunciator Rsd85 O CHI CHIN 0 CHI(4)IN These annunciators are stand-alone units that can be powered by ' CHI. O--I I 0 CH1(-)IN 0 CHI(-)IN the FACP or by an approved power supply. CHI O CH1 0)OUT 0 CHI(+)OUT CH2+ 0 I 9 CH1 H OUT 0 CHI(-)Our ![t CH2— - 0 CH2(+)IN 0 CH2(+)IN \\V • �'{+ 0 CH2(-)IN 0 CH2(-)IN II;; o _ •••• LISTED24VOC 9 CH2 N)OUT 0CH2(+)OUT $ e o�Oj..'.^.. SUPPLY CM21-I OUT 0 CH2(-)OUT �, $ I 24 VDC•0 0 24V(+)IN 024V(+)IN ®®I� O $ �anr 24 VDC-0 024v(-)IN 029V(-)IN cm a ..' 9 24V et)OUT 024V(+)OUT la C-7r=. / °° ,- w�...J • 924V(-)OUT 024V(-)OUT / Ir`S�I \ Ir tj \ - 0 GROUND GROUND RLCD-C O / Q�RLEED-C / • \ Annunciator,Class B o $ " e el °es $ $ e FACP MnuncaWr annuMiator ®®� II��LP"'.'. o % sr • RE-485 I 0 CHI(+)IN 0 CHI)4)IN i °°� CHi+ 0 0DN1(-)IN OCH1(-)IN . ra.._;.+� $ 0 $I CHI— 0 9 CHI hMOUr O CHI(y OUT �J +8Y //q (� 0 CHI(-)OUT 0 CHI(-)OUT // J e Pi �i, C(/ ill _j VA 0 CH2(+IIN 0 0H2(^)IN 'Y Y N V. 0 CH21-)IN 0 CH2(-)IN RLCD RLED24 LISTED 24 VDC 0 CH2(.)OUT 0 CH2(+)OUT Features by RLCD RLCD-C RLED-C RLED24 SUPPLY OcHz(-)OUT ecH2(-)OUT model 24 VDC+0 024V(+)IN 024VCHIN Reset ✓ ✓ ✓ 24 VDC—0 024V(-IIN 024V(-)IN Ack/Silence - -- ✓ ✓ ✓ - 024V CH OUT 024V(.)OUT 9 24V I-)OUT 0 24V(-)OUT Fire Alarm ✓ ✓ V - Supervisory ✓ ✓ ✓ 1 0 GROUND t 0 GROUND 1 Ground Fault ✓ ✓ ✓ - Trouble V ✓ ✓ - Controls Enabled ✓ ✓ V - Expander Ack/Silence ✓ ✓ ✓ - Annunciator __._.. Reset ✓ ✓ - - AnnurMaator First Expander Second Expander Signal Silence ✓ ✓ - OUT IN OUT IN OUT y(-)0 OV(-) v(-)0- OvA v(-)0 Drill ✓ V - v(*)0 0v(+) v(H O O- v(N v(+)0 Lamp Test_.. . ✓ -. s ✓ - F O OF F(3 OF F0 LCD Display ✓ ✓ - - E 0 0 E E 0 +--OE EO Zone Active LEDs - - 16* 24.. D0 OD D0- OD b0 Zone Trouble LEDs - - 16 24 C 0 O c c 0. c c 0 *zones 13-16 maybe selected as Supervisory on 1064 e 0 —0 1) a '_--0 e B m -"zones 13-16 and 29-32 may be selected as Supervisory on 101000 a O 0 a a 0 -O a a O _ Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an Remote Keyswitch LED-based graphic annunciator. Am"map SRA-R The annunciator card supports 32 LEDs and 16 switches on the jaitKEvswrraH(-)0 0TBI-I um.KEYS graphic panel display. It includes status LEDs and an internal WITCH et)O 0'BI.2 buzzer. It The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc c1,44 voltage .40000 The annunciator communicates with the FACP on the RS-485 Maximum 200 mA '1 data riser.This can be configured for Class A or Class B commu- current nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) li,, It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box I'_i i approved power supply. Termination Screw terminals \ ®" Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm — Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) Contact Normally open Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration Maximum current 10 mA per LED Page 2 of 4 - E85005-0128 Issue 1 Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER � Mounting slot ITC DIP switch I / (0..,-_-) \ 1- ,8 _Remote keyswitch RS-485 riser d .� terminals terminals _ �_ ' Expander cable ° Power terminals - terminals �� ° 7 O Communication $w �:d J LEDs 0 Expander 0 J Mounting slot ® il°niununinumnu` ----- ---E 1 ,il�,. EXPANDER CABLE \ • l-F.M @ Jill---_____IExpander cable _ F,. Expander cable \ terminals I�I"II . ^" terminals ® B ® O s. DIP switch settings \ O Switch Description and values ° Si to S5 The annunciator network address(in binary). _.: Network The factory setting is for address 2. address Examples: 10000=1 01000=2 11000=3 00100=4 S6 Network OFF=9600 baud(factory default setting) 1 ■ baud rate ON=38,400 baud Onnnn�nn.non C S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface 1 A mounted protection for annunciators and extenders.Each con- 11 sists of a back plate,hinged cover,and key lock. The enclosures are 16-gauge welded steel with a white, painted 6.0 in finish. Each enclosure includes a security lock and two keys.The 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a MOD D mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. 0.9 in 2.3 cm ) '\ 4 \ 4 RA-ENC1 Mil I I) ) 9.5in .I ( 24.1 cm 1 2.0 in 1 9.8 in 5.1 cm 24.9cm c\ / Dimensions(H x W x D) IN ) RA-ENC1 6.3 x 9.8 x 2.0 in(16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in(30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the enclosure,to permit inserting and removing the key,and opening the door PA-ENC2 through 90 degrees. Page 3 o1 4 ' , . : E85005-0128 t. Issue 1 Specifications EDWARDS RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC,continuous. LIFE SAFETY&INCIDENT MANAGEMENT Standby current 99 mA 98 mA 28 mA 6 rnA Alarm current 115 mA 113 mA 62 mA 34 mA Contact us... RS-485 communications Class A or Class B,9600 baud Email: edwards.fire@fs.utc.com Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot Web: Edwards-fire.com minimum).Maximum wire run is 4,000 ft.(1,219 m) Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised EDWARDS is a UTC brand. Ground fault impedance 0 1016 Corporate Park Drive Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) Display area 4 lines of 20 characters each ID 2016 United Technologies Corporation. Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) All rights reserved. Mounting North American 4-inch square electrical box or listed enclosure Agency Listing UL,ULC Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Description• Remote Annunciators RLCD LCD text annunciator without common controls.English. RLCD-R LCD text annunciator without common controls.English.Red. RLCDF LCD text annunciator without common controls.French. — ► 'RLCD-C LCD text annunciator with common controls.English, RLCD-CR LCD text annunciator with common controls.English.Red. RLCD-CF LCD text annunciator with common controls.French. RLED-C 16-pair LED zone annunciator with common controls.English. RLED-CR 16-pair LED zone annunciator with common controls.English.Red. RLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls(Lock/ Unlock). 27193-16 Electrical box,surface mount,white,single-gang,for RKEY. Page 4 of 4 E85005-0128 Issue 1