Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
ft2 c 7- 07O/ 7/b ,cw Mgoevstaci RECEIVED KOHLERe OCT 2 2019 Model: 1 25REZGC • CITY OF TIGARD BUILDING DIVISION 208-600 V Gas 09001 EPA-Certified for Stationary Standard Features G KOHLER. Emergency Applications • Kohler Co. provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are Ratings Range prototype-tested,factory-built, and production-tested. 60 Hz • The 60 Hz generator set offers a UL 2200 listing. Standby: kW 91-125 • At 60 Hz,the generator set accepts rated load in one kVA 91-156 step. • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and Ili installed per NFPA standards. ■ �r 11,_II • A one-year limited warranty covers all generator set .�_►_.� ���i 1 0+ systems and components. Two-and five-year ID r, . .t • Ir I extended limited warranties are also available. 'I�� ��;i��Y� v11, __ • Alternator features: II(` ; J 0 The unique Fast-Response®X excitation system elf ,, i delivers excellent voltage response and 5 -` P n'tl� l short circuit capability using attire-earth, ►fir, I-•IiI permanent magnet(PM)-excited alternator. ill The brushless, rotating-field alternator has M..V � �I—lu-lam la sf broadrange reconnectability. Q ■ ` ■ 0 • Other features: o Kohler designed controllers for one-source system integration and remote communication. See Controllers on page 3. o The electronic, isochronous governor incorporates an integrated drive-by-wire throttle body actuator delivering precise frequency regulation. b • Generator Set Ratings Natural Gas LP Gas 130°C Rise 130°C Rise Standby Rating Standby Rating Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 120/208 3 60 124/155 430 105/131 364 127/220 3 60 125/156 410 105/131 344 120/240 3 60 124/155 373 105/131 316 4 4R12X 120/240 1 60 91/91 379 91/91 379 139/240 3 60 125/156 376 105/131 316 220/380 3 60 112/140 213 105/131 199 277/480 3 60 125/156 188 105/131 158 347/600 3 60 125/156 150 105/131 126 F2n12ng a Rn 195/15R a341 106/133 368 127/220 3 60 125/156 410 106/133 348 120/240 3 60 125/156 376 106/133 319 4R13X 120/240 1 60 107/107 446 100/100 417 139/240 3 60 125/156 376 106/133 319 220/380 3 60 124/155 235 106/133 201 277/480 3 60 125/156 188 106/133 159 • 347/600 3 60 125/156 150 106/133 128 4T13X 120/240 1 60 125/125 521 105/105 438 RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage, There is no overload capability for this rating. Prime Power Ratings: At varying load,the number of generator set operating hours a unlimited. A 10%overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. For limited running time and continuous ratings,consult the factory. Obtain technical information bulletin(nB-101)for ratings guidelines.complete ratings definitions,and site condition de-ates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any - obligation or lability whatsoever. For dual fuel engines,use the LP gas ratings for both the primary and secondary fuels. G4-221 (125REZGC) 11/18f • Alternator Specifications Specifications Alternator • NEMA MG1, IEEE, and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Type 4-Pole,Rotating-Field • Sustained short-circuit current of up to 300%of the rated Exciter type Brushless.Rare-Earth current for up to 10 seconds. Permanent Magnet Leads:quantity,type • Sustained short-circuit current enabling downstream circuit -. 4RX 12,Reconnectable breakers to trip without collapsing the alternator field. 4TX 4, 110-120/220-240 V • Self-ventilated and dripproof construction. Voltage regulator Solid State,Volts/Hz Insulation: NEMA MG1 • Windings are vacuum-impregnated with epoxy varnish for Material Class H dependability and long life. Temperature rise 130°C,Standby Bearing:quantity,type 1,Sealed • Superior voltage waveform from a two-thirds pitch stator and Coupling Flexible Disc skewed rotor. Amortisseur windings Full Voltage regulation,no-load to full-load Controller Dependent One-step load acceptance 100%of Rating Unbalanced load capability 100%of Rated Standby Current Peak motor starting kVA: (35%dip for voltages below) 480 V 4R12X(12 lead) 448 (B0 Hz) 480 V 4R13X(12 lead) 540 (60 Hz) 240 V 4T13X(4 lead) 440 (60 Hz) Application Data Engine Engine Electrical Engine Specifications Engine Electrical System Manufacturer PSI Ignition system Individual Coil Engine:model,type Industrial 8.8 L,4-Cycle, Near Plug Ignition Turbocharged Battery charging alternator: Cylinder arrangement V-8 Ground(negative/positive) Negative Displacement,L(cu.in.) 8.8(537) Volts (DC) 12 Bore and stroke,mm (in.) 110 x 114(4.35 x 4.5) Ampere rating 70 Compression ratio 10.1:1 Starter motor rated voltage(DC) 12 Piston speed,m/min. (ft./min.) 411 (1350) Battery,recommended cold cranking Main bearings:quantity,type 5,Bi-Metal Steel and amps(CCA): Aluminum Qty.,rating for-18°C(0°F) 1,630 Rated rpm 1800 Battery voltage(DC) 12 y , Max.power at rated rpm (NG),kW(HP) 142(190) Max.power at rated rpm, (LPG)kW(HP) 121 (162) Fuel Cylinder head material Cast Iron Piston type and material Flat Top,Hypereutectic Fuel System Cast Alum. Fuel type Natural Gas, LP Gas,or Crankshaft material Forged Steel, Induction Dual Fuel Hardened,Tangential Fillet Fuel supply line inlet 1.5 NPTF Valve(exhaust)material Int.-A193 Exh. Inconel Natural gas fuel supply pressure,kPa Governor type Electronic (in. H2O) 1.74-2.74(7-11) Frequency regulation,no-load to full-load Isochronous LPG vapor withdrawal fuel supply Frequency regulation,steady state ±0.5% pressure,kPa(in.H2O) 1.24-2.74(5-11) Frequency Fixed Dual fuel engine,LPG vapor withdrawal Air cleaner type,all models Dry fuel supply pressure,kPa(in.H2O) 1.24(5) Exhaust Fuel Composition Limits* Nat.Gas LP Gas Methane,%by volume 90 min. 1.2 max. Exhaust System Ethane,%by volume 4.0 max. 10 max. Exhaust manifold type Dry Propane,%by volume 1.0 max. 96 max. Exhaust flow at rated kW,m3/min.(cfm) 21.1 (745) Propene,%by volume 0.1 max. 3 max. Exhaust temperature at rated kW,dry C4 and higher,%by volume 0.3 max. 3 max, 1200 Sulfur,o mass 25 max. exhaust, °C(°F) 649 ( ) Lower heating value, Maximum allowable back pressure, MJ/m3(Btu/ft3),min. 33.2(890) 78.8(2116) kPa(in. Hg) 10.2(3.0) * Fuels with other compositions may be acceptable. If your fuel is Exhaust outlet size at engine hookup, Flanged Outlet at Catalyst outside the listed specifications,contact your local distributor for mm(in.) see ADV drawing further analysis and advice. G4-221 (125REZGG) 11/18f Application Data Lubrication Controllers - Lubricating System - $ Type Full Pressure : y t Oil pan capacity, L(qt.) § 8.0(8.5) Oil pan capacity with filter,L(qt.)§ 8.5(9.0) a ab OO Oil filter:quantity,type§ 1,Cartridge § Kohler recommends the use of Kohler Genuine oil and filters. .- -® 0 Cooling APM402 Controller Radiator System Provides advanced control,system monitoring,and system diagnostics for optimum performance and compatibility. Ambient temperature, 'C('F)* 50(122) • Digital display and menu control provide easy local data access Engine jacket water capacity,L(gal.) 13.4(3.54) • Measurements are selectable in metric or English units Radiator system capacity, including • Remote communication thru a PC via network or engine,L(gal.) 27.6(7.3) serial configuration Engine jacket water flow,Lpm (gpm) 125(33) • Controller supports Modbus®protocol Heat rejected to cooling water at rated • Integrated hybrid voltage regulator with-0.5%regulation kW,dry exhaust,kW(Btu/min.) 73.5(4184) • Built-in alternator thermal overload protection Heat rejected to engine oil at rated kW, • NFPA 110 Level 1 capability kW(Btu/min.) 1.2(67.5) Refer to G6-161 for additional controller features and accessories. Water pump type Centrifugal Fan diameter,including blades,mm(in.) 660(26.0) Fan,kWm (HP) 8.9(12.0) , -®- Max.restriction of cooling air,intake and Cie" e'- ��: discharge side of radiator,kPa(in. H20) 0.125(0.5) : '' * Enclosure with enclosed silencer reduces ambient temperature capability by 5°C(9°F). Decision-Maker°550 Controller Operation Requirements Provides advanced control,system monitoring,and system diagnostics Air Requirements with remote monitoring capabilities. • Digital display and keypad provide easy local data access Radiator-cooled cooling air, • Measurements are selectable in metric or English units m3/min. (scfm)c 306(10800) • Remote communication thru a PC via network or Combustion air,m3/min.(cfm) 6.9(244) modem configuration Heat rejected to ambient air: • Controller supports Modbus®protocol Engine,kW(Btu/min.) 21.6(1230) • Integrated voltage regulator with±0.25%regulation Alternator, kW(Btu/min.) 15.7(893) • Built-in alternator thermal overload protection Air density=1.20 kg/m3(0.075 Ibm/ft3) • NFPA 110 Level 1 capability Refer to G6-46 for additional controller features and accessories. Fuel Consumption$ - Natural Gas, m3/hr.(cfh)at%load Standby Ratings_ '-� - i 100% 42.8 (1511 0 ov®nt l 75% 34.1 (1204) j 50% 25.2 (890) 0. 25% 16.5 (583) , 0% 6.8 (240) LP Gas,ma/hr.(cfh)at%load Standby Ratings Decision-Maker°6000 Paralleling Controller Provides advanced control,system monitoring,and system diagnostics 100% 17.7 (626) with remote monitoring capabilities for paralleling multiple generator 75% 13.4 (473) sets. 50% 9.5 (334) • Paralleling capability with first-on logic,synchronizer,kW and kVAR 25% 5.9 (209) load sharing,and protective relays 0% 2.7 (95) • Digital display and keypad provide easy local data access $ Nominal fuel rating: Natural gas,37 MJ/m3(1000 Btu/ft.3) • Measurements are selectable in metric or English units LP vapor,93 MJ/m3(2500 Btu/ft.3) • Remote communication thru a PC via network or modem configuration LP vapor conversion factors: • Controller supports Modbus®protocol 8.58 ft.3=1 lb. • Integrated voltage regulator with-0.25%regulation 0.535 m3=1 kg. • Built-in alternator thermal overload protection - 36.39 ft.3=1 gal. • NFPA 110 Level 1 capability . Refer to G6-107 for additional controller features and accessories. Mod husa is a registered trademark of Schneider Electric, G4-221 (125REZGC) 11/18f KOI.ILER Phone 9 CO.,45Kohler,Fax 53044-16 USA Phone 920-457-4441,Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada,phone 1-800.544-2444 KOHLERPower.com Standard Features Miscellaneous • Alternator Protection ❑ Air Cleaner Restrictor Indicator • Battery Rack and Cables 0 Certified Test Report • Closed Crankcase Ventilation(CCV) Filters 0 Crankcase Ventilation Heater • Customer Connection Recommended for ambient temperatures below 0°C(32°F) (Standard with Decision-Maker®6000 controller only) ❑ Engine Fluids Added • Electronic,lsochronous Governor ❑ Rated Power Factor Testing • Gas Fuel System (includes fuel mixer,electronic secondary gas ❑ Rodent Guards regulator,gas solenoid valve,and flexible fuel line between the Literature engine and the skid-mounted fuel system components) • ❑ General Maintenance • Integral Vibration Isolation ❑ NFPA 110 • Local Emergency Stop Switch ❑ Overhaul • Oil Drain Extension ❑ Production • Operation and Installation Literature • Three-Way Exhaust Catalyst Warranty 0 2-Year Basic Limited Warranty Available Options ❑ 5-Year Basic Limited Warranty Approvals and Listings ❑ 5-Year Comprehensive Limited Warranty • CSA Certified Other Options ] IBC Seismic Certification ] UL 2200 Listing Hurricane Rated Enclosure Enclosed Unit j Sound Enclosure(with enclosed critical silencer) ❑ Weather Enclosure(with enclosed critical silencer) ❑ Open Unit ❑ ] Exhaust Silencer,Critical(kit: PA-324470) ❑ • Flexible Exhaust Connector,Stainless Steel Fuel System ❑ Dual Fuel NG/LPG (automatic changeover) ❑ Flexible Fuel Line (required when the generator set skid is spring mounted) ❑ Gas Filter j LP Liquid Withdrawal(vaporizer) Dimensions and Weights ] Secondary Gas Solenoid Valve Overall Size,L x W x H, mm(in.): Controller Wide Skid 2800 x 1120 x 1538(110.2 x 44.1 x 60.6) ] Common Fault Relay Narrow Skid 2400 x 864 x 1538(94.5 x 34.0 x 60.6) j Communication Products and PC Software Weight(radiator model),wet,kg (lb.): 1365(3009) ❑ Customer Connection (Decision-Maker®550 and 6000 controllers only) ❑ Dry Contact(isolated alarm) (Decision-Maker®550 and 6000 controllers only) ❑ Two Input/Five Output Module(APM402 controller only) j�- ❑ Remote Annunciator Panel I ❑ Remote Audiovisual Alarm Panel H (Decision-Maker®550 and 6000 controllers only) J Remote Emergency Stop j Run Relayt 0 D Cooling System LL ❑ Block Heater,1800 W, 110-120 V �—W r L j NOTE:This drawing is provided for reference only and should not be used for planning ❑ Block Heater,2000 W, 190-240 V installation. Contact your local distributor for more detailed information. Required for ambient temperatures below 10°C(50°F) DISTRIBUTED BY: ❑ Block Heater,2000 W,120 V (Only available with LP liquid withdrawal) ❑ Radiator Duct Flange Electrical System ❑ Alternator Strip Heater ❑ Battery ❑ Battery Charger,Equalize/Float Type ❑ Battery Heater ❑ Line Circuit Breaker(NEMA1 enclosure) ❑ Line Circuit Breaker with Shunt Trip(NEMA1 enclosure) ®2012,2013,2016,2018 by Kohler Co. All rights reserved. G4.221 (125REZGC) 11/18f Model KSS Automatic Transfer Switches ICOHLER. Power Systems Standard Specific-Breaker Rated 09001 Transfer Switch Standard Features am, kr ;YST-M. • UL 1008 listed at 208-480 VAC .,ar'or+>,:,xeo'srece° file#E58962 (automatic), #E86894(nonautomatic) • CSA certification available i • IBC seismic certification available ljll I • Standard-transition operation )' • Silver tungsten alloy contacts on 400-600 amp models gig;gip a t • Solid or switched neutral • • r 4- • Available with either automatic or non-automatic control iiirrigge (non-automatic control requires the Decision-Makere MPAC 1200 controller) • Available in 2, 3, or 4 pole configurations I . High withstand/closing ratings,for use with specific breakers only • Electrically operated, mechanically held mechanism • Double-throw, mechanically interlocked design (break-before-make power contacts) • Enclosed arc chambers with arc chutes il " 1'0-ii.oA g • Front-accessible contacts for easy inspection • Main shaft auxiliary position-indicating contacts (see page 3 for contact ratings) • Standard one-year limited warranty. Extended limited warranties are available. Available Controllers •Decision-Maker' MPAC 750 •Decision-Makerr, MPAC 1200 Ratings Model Current Voltage,Frequency KSS 40-600 amps 208-600 VAC, 50/60 Hz 800-1000 amps 208-480 VAC, 50/60 Hz G11-136(Model KSS Transfer Switch) 11/14 Page 1 Available Automatic Transfer Switch Controllers Select one of the following controllers for your automatic transfer switch. Decision-Maker® MPAC 750 Controller Decision-Maker® MPAC 1200 Controller N 44, t� N A` ♦NMI 3 L x" :_Pfa '"A;p .7W , KOHLEft MP/C 12G0 A A L^--1C3 C3 CD CD 0 • Test pushbutton • LCD display, 4 lines x 20 characters, backlit • Exercise pushbutton • Complete programming and viewing capability at the door • LED indicators: Source available, transfer switch position, using the keypad and LCD display service required (fault),and"not in auto" • LED indicators: Source available, transfer switch position, • Programmable voltage pickup and dropout settings service required (fault),and "not in auto" • Programmable time delays • Programmable voltage and frequency pickup and dropout • Seven day generator exerciser settings • Two programmable inputs and two programmable outputs • Programmable time delays • Programmable generator exerciser • Modbus communication standard • Time-based load control • RS-485 communication standard • Two programmable inputs and two programmable outputs • Ethernet communication optional For more information about Decision-Maker®MPAC 750 • Up to four I/O extension modules available features and functions, see specification sheet G11-126. • Modbus communication standard • RS-485 communication standard • Ethernet communication optional For more information about Decision-Maker® MPAC 1200 features and functions, see specification sheet G11-127. Codes and Standards The ATS meets or exceeds the requirements of the following • IEC Specifications for EMI/EMC Immunity: • specifications: 0 CISPR 11, Radiated Emissions • Underwriters Laboratories UL 1008, Standard for Automatic IEC 1000-4-2, Electrostatic Discharge Transfer Switches for Use in Emergency Standby Systems file#E58962(automatic),#E86894 (nonautomatic) 0 IEC 1000-4-3, Radiated Electromagnetic Fields • CSA C22.2 No. 178 certification available, file#LR58301 0 IEC 1000-4-4, Electrical Fast Transients (Bursts) • NFPA 70, National Electrical Code 0 IEC 1000-4-5, Surge Voltage • NFPA 99, Essential Electrical Systems for Health Care o IEC 1000-4-6, Conducted RF Disturbances Facilities o IEC 1000-4-8, Magnetic Fields • NFPA 110, Emergency and Standby Power Systems o IEC 1000-4-11, Voltage Dips and Interruptions - • IEEE Standard 446, IEEE Recommended Practice for • IEEE 472 (ANSI C37.90A) Ring Wave Test Emergency and Standby Power Systems for Commercial • Seismic certification in accordance with the International and Industrial Applications Building Code is available. (Accessory kit is required for • NEMA Standard ICS 10-2005, Electromechanical AC seismic certification.) Transfer Switch Equipment 0 IBC 2000, referencing ASCE 7-98 and ICC AC-156 o IBC 2003, referencing ASCE 7-02 and ICC AC-156 • EN61000-4-4 Fast Transient Immunity Severity Level 4 o IBC 2006, referencing ASCE 7-05 and ICC AC-156 • IEC 60947-6-1, Low Voltage Switchgear and Control Gear; o IBC 2009, referencing ASCE 7-05 and ICC AC-156 Multifunction Equipment; Automatic Transfer Switching 0 IBC 2012, referencing ASCE 7-10 and ICC AC-156 Equipment • EN61000-4-5 Surge Immunity Class 4 (voltage sensing and programmable inputs only) G11-136(Model KSS Transfer Switch) 11/14 Page 2 Application Data Environmental Specifications Operating Temperature -20°C to 70°C(-4°F to 158°F) Storage Temperature -40°C to 85°C(-40°F to 185°F) Humidity 5%to 95%noncondensing UL-Listed Solderless Screw-Type Terminals for External Power Connections Switch Range of Wire Sizes,Copper or Aluminum* Rating, Model Amps Normal,Emergency,and Load Neutral Ground 40-150 (1)#8 to 3/0 AWG t (3)#6-3/0 AWG 200-225 (1)#6 AWG to 250 KCMIL t • 260 (1)#6 AWG to 350 KCMIL t (3)#4-600 KCMIL or (3)#6-3/0 AWG 400 (1)#4 AWG to 600 KCMIL t or (6) 1/0-250 KCMIL •KSS (2) #1/0 AWG to 250 KCMIL t 600 (2)#2 AWG to 600 KCMIL t (3)#4-600 KCMIL or (6)1/0-250 KCMIL (3)#4-600 KCMIL or 800 (2)#1/0 AWG to 750 KCMIL (6) 1/0-250 KCMIL 1000 (12)#2-600 KCMIL (4)#2 AWG to 600 KCMIL * Use 60°C minimum wire for#14 to#1 AWG. Use 75°C minimum wire for 1/0 AWG and larger. T Use copper wire only. Contact Ratings Motor Load Resistive Load Inductive Load NC NO Engine Start Contacts 2 A @ 30 VDC N/A N/A N/A Auxiliary Contacts,(40-600A)' 15 A @ 250 VAC N/A N/A N/A Auxiliary Contacts,(800-1000A)r 15 A @ 480 VAC 15 A @ 250 VAC; 5 A @ 125 VAC; 2.5 A @ 125 VAC; 6 A @ 500 VAC 3 A @ 250 VAC; 1.5 A @ 250 VAC; 1.5 A @ 500 VAC 0.75 A @ 500 VAC y Auxiliary position-indicating contacts,one set Normal and one set Emergency Weights and Dimensions Weights and dimensions are shown for transfer switches in NEMA type 1 and type 3R enclosures, and open units. Consult the factory for open units and other enclosures. Note: Weights and dimensions are provided for reference only and should not be used for planning installation. See your local distributor for submittal drawings. Dimensions mm(in.) Weight kg(lb.) Amps NEMA Type Height Width Depth§ 2-Pole 3-Pole 4-Pole 40-225 1,3R 791 (31.1) 450 (17.7) 316 (12.5) 28 (62) 30 (65) 31 (68) 260-400 1,3R 1223 (48.1) 560 (22.0) 362 (14.3) 52 (115) 56 (123) 59 (131) 600 1,3R 1702 (67.0) 610 (24.0) 514 (20.2) 179 (395) 183 (403) 186 (410) 800 1,3R 1932 (76.1) 864 (34.0) 515 (20.3) N/A 226 (498) 236 (520) 1000 1,3R 1932 (76.1) 864 (34.0) 515 (20.3) N/A 231 (509) 241 (531) § Allow enough room to fully open the door for inspection and service per NEC and local codes.The NEMA type 3R enclosures have a security cover on the controller that extends 54 mm (2.1 in.)beyond the door. G11-136(Model KSS Transfer Switch) 11/14 Page 3 • . Withstand and Close-On Ratings (WCR) Ratings Summary . The transfer switch is rated for use on a circuit capable of delivering not more than the RMS symmetrical Amperes listed at the specified maximum voltage below,but no greater than the interrupting capacity of the selected circuit breaker or fuse. Circuit breakers and fuses are supplied by the customer. Certified Withstand Current Ratings in RMS Symmetrical Amperes'l Specific Coordinated Breaker Rating, With Current-Limiting Fuses (see the following tables) Any Breaker Ratings** Fuse Maximum Circuit Maximum Circuit Maximum Circuit Time Switch Size, Amps Amps Amps Duration, Rating, Fuse Max Maximum Maximum Seconds Amps Class Amps 480 VAC 600 VAC Voltage 480 VAC 600 VAC Voltage 480 VAC 600 VAC Max. 40-150 J 400 200,000 200,000 600 V 30,000 22,000 600 V 10,000 10,000 200-225 J 400 200,000 N/A 600 V 30,000 22,000 600 V 10,000 10,000 0.025 260 N/A N/A N/A N/A 480 V 35,000 N/A N/A N/A N/A N/A J 600 200,000 200,000 400 RK5 600 100,000 N/A 600 V 50,000 42,000 600 V 35,000 35,000 0.050 RK1 600 N/A N/A N/A N/A 600 V 50,000 42,000 N/A N/A N/A N/A 800 L 3000 1000 L 4000 200,000 N/A 480 V 65,000 N/A N/A N/A N/A N/A r All values are available symmetrical RMS Amperes and tested in accordance with the withstand/closing requirements of UL 1008. **Applicable to breakers with instantaneous trip elements. Ratings with Specific Manufacturers' Circuit Breakers Withstand and close-on ratings (WCR) in RMS symmetrical Amperes for specific manufacturers'circuit breakers. Molded-Case Circuit Breakers Switch WCR, ' Rating, Voltage, Amps Max.Size, Amps Max. RMS Manufacturer Type Amps FCL 100 Eaton JGS,JGH,JGC,JGU,JGX,JBD,JD, HJD,JDC, LCL,LCLA 250 LDC,CLDC,KDB,KD,HKD,KDC,LD,CLD,HLD,CHLD 400 . CED6,HED4,HED6 125 ITE/Siemens CFD6,FD6A, FXDB,HFD6,HFXD6,HHFD6, HHFXD6 250 CJD6 400 480 30,000 SEL,SEP,THLC1 150 THLC2 225 40 General Electric • SFH,SFL,SFP 250 80 SGH,SGL,SGP,FGN,FGH,FGL,FGP 400 100 150 HG,HJ,HL, HR 150 I 200 Schneider JJ,JL,JR 250 LG,LJ, LL,LR 400 225 - JGS,JGH,JGC,JGU,JGX,JDB,JD,HJD,JDC,LCL, LCLA 250 Eaton LDC,CLDC, KDB,KD,HKD,KDC,LD,CLD,HLD,CHLD 400 CED6, HED4,HED6 125 ITE/Siemens CFD6,FD6,FXD6,HFD6,HFXD6, HHFD6,HHFXD6 250 600 22,000 SEL,SEP,THLC1 150 THLC2 225 General Electric SFH,SFL,SFP 250 SGH,SGL,SGP,FGN,FGH,FGL,FGP 400 G11-136(Model KSS Transfer Switch) 11/14 Page 4 Molded-Case Circuit Breakers Switch WCR, Rating, Voltage, Amps Max.Size, Amps Max. RMS Manufacturer Type Amps JGS,JGH,JGC,JGU,JGX,JDB,JD, HJD,JDC, LCL,LCLA 250 Eaton LDC,CLDC,LD,CLD,HLD,CHLD,KDB,KD, HKD, KDC 400 CED6,HED4,HHED6 125 ITE/Siemens CFD6,FD6,FXD6, HFD6,HFXD6,HHFD6,HHFXD6 250 SEL,SEP,THLC1 150 THLC2 225 260 480 35,000 General Electric SFH,SFL,SFP 250 SGH 350 SGH,SGL,SGP,FGN,FGH,FGL,FGP 400 HG,HJ,HL,HR 150 Schneider JJ,JL,JR 250 LG,U,LL,LR 400 HJD,JDC,JGC,JGH,JGU,JGX 250 CHLD4,CLD,HLD4,CLDC,LDC,KDC,HKD,CHMDL4,CMDL4 400 Eaton CHLD6,HDL6,CHMDL6,CMDL6,CLDC,CLD6,LDC6,CLDC6 600 CHMDL8,HMDLB,MDL8,CMDLB 800 480 50,000 ITE/Siemens CFD6,HFD6,HFXD6, HHFD6,HHFXD6 250 SFL,SFP 250 General Electric FGL, FGP 600 Schneider U,LL, LR 600 JGU,JGX 250 CLDC4,KDC,LDC4 400 Eaton 400 CLDC6,LDC6,NB Tri-Pac 600 NB Tri-Pac 800 CFD6 250 CJD6,SCLD6 400 ITE/Siemens 600 42,000 CLD6,HHLD6,HHLXD6,SCLD6 600 CMD6,HMD6,HMXD6,SCMD6,SHMD6 800 THLC1 150 FGL4,FGP4,THLC4,TLB4 400 General Electric SGL,SGP,FGL6,FGP6 600 SKL8,SKPS 800 Schneider JL,JR 250 G11.136(Model KSS Transfer Switch) 11/14 Page 5 Molded-Case Circuit Breakers Switch WCR, • Rating, Voltage, Amps Max Size, Amps Max. RMS Manufacturer Type Amps HJD,JDC,JGC,JGH,JGU,JGX 250 CHLD4,CLD,HLD4,CLDC,LDC,KDC,HKD,CHMDL4,CMDL4 400 • Eaton CHLD6,HLD6,CHMDL6,CMDL6,CLDC6,LDC6,CLD6,CLDC 600 CHMDL6,HMDL8,MDL8,CMDLB 800 480 50,000 ITE/Siemens CFD6,HFD6,HFXD6,HHFD6, HHFXD6 250 _ SFL,SFP 250 General Electric FGL,FGP 600 Schneider LJ,LL,LR 600 JGU,JGX 250 CLDC4,KDC,LDC4 400 Eaton 600 CLDC6,LDC6,NB Tri-Pac 600 NB Tri-Pac 800 CFD6 250 CJD6,SCLD6 400 ITE/Siemens 600 42,000 CLD6, HHLD6,HHLXD6,SCLD6 600 CMD6,HMD6,HMXD6,SCMD6,SHMD6 800 THLC1 150 FGL4,FGP4,THLC4,TLB4 400 General Electric SGL,SGP,FGL6,FGP6 600 SKL8,SKP8 800 Schneider JL,JR 250 TRI-PAC NB,CHMDL,HMDL,CHND,HND,NDC,CNDC 800 Eaton/ TRI-PAC NB,CNDC,NDC,CRDC,TRI-PAC PB,RDC,CHND,HND, Cutler-Hammer 1200 RD.CRD Schneider/ MJ,PJ,PL,RJ 800 800 Square D PJ, PL,RL 1000 1000 65,000 480 CMD6,HMD6,SCMD6,SHMD6,CND6,HND6,SCND6,SHND6, ITE/Siemens CPD6 800 CND6,HND6,SCND6,CPD6,SHND6, HPD6 1200 TBe,TC,THC,THP 1000 General Electric THC,THP,TRP 1200 G11.136(Model KSS Transfer Switch) 11/19 Page 6 Transfer Switch Accessories Q Seismic Certification Accessories are available either factory-installed or as loose •Certification depends on application and geographic kits, unless otherwise noted. location. Contact your distributor for details. •Available for 40-1000 amp KSS models with NEMA 1,3R, ❑ CSA Certification 4,4X, and 12 enclosures ❑ Digital Meter(with MPAC 1200 only) ❑ Surge Protection Device (SPD) •Measure and display voltage, current,frequency, and •Surge protection reduces transient voltages to harmless power for both sources levels •Programmable visual alarms for high voltage, low voltage, •Protection modes: L-L/L-N/L-G/N-G and high current •Replaceable phase and neutral cartridges for service •Three digital outputs •Frequency: 50-60 Hz •Serial port for optional network connections •Operating Temperature Range: -40 to 176°F •Password-protected programming menus (-40 to 80°C) •Joystick operation •Remote contacts for customer-supplied status indicators: • Contacts: 1 NO, 1 NC Factory-installed Min Load: 12VDC/10 mA •Three digital outputs Max. Load: 250 VAC/1 A •Joystick operation Wire Size(max.): 16AWG •Fuse protection: 30 amps/600 V ❑ Extended Limited Warranties •UL 1449, 3rd Edition for Type 2 applications •2-year basic •IEC 61-643-1, 2nd Edition T2/11 •5-year basic •See additional specifications below •5-year comprehensive •10-year major components Additional Controller Accessories ❑ Export Packaging See the controller spec sheet for more information. ❑ Heater,Anti-Condensation ❑ Accessory Modules (with MPAC 1200 only) •Hygrostat-controlled 120 VAC strip heater •Alarm Module (customer-supplied voltage source required) •External Battery Supply Module •100 or 250 watts(sized for enclosure) •Input/Output Module • •Protective 15 amp circuit breaker •High-Power Input/Output Module ❑ Literature Kits ❑ Controller Disconnect Switch •Production literature kit (one kit is included with each transfer switch) ❑ Ethernet Communications •Overhaul literature kit ❑ Current Sensing Kit (with MPAC 1200 only) ❑ Neutral Assembly ❑ Line-to-Neutral Voltage Monitoring •Available as loose kit for open units (with MPAC 1200 only) ❑ RSA Ill Remote Serial Annunciator ❑ Padlockable User Interface Cover •Monitors the generator set •Monitors Normal and Emergency source status and ❑ Supervised Transfer Control Switch connection (with MPAC 1200 only) •Monitors ATS common alarm •Allows remote testing of the ATS For more information, see specification sheet G6-139. SPD Specifications Max. Limiting Voltage,(L-N/N-G/L-G) Maximum Nominal , Discharge UL VPR 3rd Ed (kV) Short Circuit Continuous Voltage Current (L-N/N-G/L-G) Withstand Operating (V ±15%) (kA) Phase Poles (kV) at 3kA at 10kA Current(kA) Voltage(VAC) 240/120 40 Split 3 0.6/1.2/0.7 0.6/0.4/0.6 0.8/0.7/0.8 200 175/350 208/120 40 Wye 4 0.6/1.2/0.7 0.6/0.4/0.6 0.8/0.7/0.8 200 175/350 480/277 40 Wye 4 1.0/1.2/1.1 1.0/0.4/1.0 1.2/0.7/1.2 200 320/460 240/120 40 HLD 4 1.0/1.2/1.1 1.0/0.4/1.0 1.2/0.7/1.2 200 320/460 600/347 40 Wye 4 1.3/1.2/1.4 1.3/0.4/1.3 1.5/0.7/1.5 200 440/880 G11-136(Mader KSS Transfer Switch) 11/14 Page 7 KOHLER CO.,Kohler,Wisconsin 53044 USA Kohler Power Systems Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters For the nearest sales and service outlet in the 7 Jurong Pier Road US and Canada,phone 1-800-544-2444 Singapore 619159 KOHLERPower.com Phone(65)6264-6422,Fax(65)6264-6455 Model Designation Model Mechanism Transition Controls Voltage Poles Enclosure Current Rating Miscellaneous ■ Record the transfer switch model designation in the boxes. The transfer switch model designation defines characteristics and ratings as explained below. Sample Model Designation: KSS-JCNA-01 00S Model Number of Poles/Wires K: Kohler N: 2 Poles/3 Wires, Solid Neutral T: 3 Poles/4 Wires, Solid Neutral Mechanism V: 4 Poles/4 Wires, Switched Neutral S: Standard (Specific-Breaker) Enclosure Transition A: NEMA 1 D: NEMA 4 S: Standard e: NEMA 12 F: NEMA 4X C: NEMA 3R G: Open Unit Controller A: Decision-Maker®MPAC 1200,Automatic Current,Amps B: Decision-Maker®MPAC 1200, Non-Automatic 0040 0200 600 J: Decision-Maker®MPAC 750,Automatic 0080 0225 800 0100 0260 1000 Voltage/Frequency 0150 0400 C: 208 Volts/60 Hz K: 440 Volts/60 Hz D: 220 Volts/50 Hz M: 480 Volts/60 Hz Connections F: 240 Volts/60 Hz N: 600 Volts/60 Hz S: Standard G: 380 Volts/50 Hz P: 380 Volts/60 Hz Note: Some selections are not available for every model. H: 400 Volts/50 Hz R: 220 Volts/60 Hz Contact your Kohler distributor for availability. J: 416 Volts/50 Hz DISTRIBUTED BY: Availability is subject to change without notice.Kohler Co.reserves the right to change the design or specifications without notice and without ' any obligation or liability whatsoever.Contact your local Kohler©Power • Systems distributor for availability. ®zola by Kohler co. All rigors reserved. G11-136(Model KSS Transfer Switch) 11/14 Page 8