Report FPS 202o- -7 i i3'2-'2.1 (cR) . RECEIVED tqiti JUN 1 1 2020 Worldwide www.tyco-fire.com Contacts ^ITv OP TIGARD iNIS Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Corrosion-resistant coatings, where applicable, help extend the life of Description copper alloy sprinklers beyond that -' �E r "'K� p which occurs when exposed to 1'in-\ , „ t corrosive atmospheres. Although �'' TYCO Series EC 11 and EC-14 corrosion-resistant coated sprinklers E x "I Extended Coverage Upright and . passed standard corrosion tests of Pendent Sprinklers are decorative ii glass-bulb sprinklers designed for use the applicable approval agencies, this g,0 - testing is not representative of all pos- �f- in light or ordinary hazard occupancies. ; They are intended for use in automatic sible corrosive atmospheres. Conse k ' sprinkler systems designed in accor quently,it is recommended that the end • _ dance with standard installation rules, user be consulted with respect to the such as NFPA 13,for a maximum coy- suitability of these corrosion resistant erage area of 400 ft2(37,2 m2)as com- coatings for any given corrosive envi- pared to the maximum coverage area ronment. The effects of ambient tern- of 130 ft2(12,1 m2)for standard cover- perature, concentration of chemicals, age sprinklers used in ordinary hazard and gas/chemical velocity should be .. a occupancies, or the maximum cover- considered, along with the corrosive i age area of 225 ft2 (20,6 m2) for stan- nature of the chemical to which the +: ,!, r dard coverage sprinklers used in light sprinklers will be exposed. hazard occupancies. NOTICE y" Series EC-11 and EC-14 Extended Series EC 11 and EC-14 Extended Cov- C-UL Listing permits ,y Coverage Sprinklers feature a UL and that their use erage Sprinklers described herein must a ben maintained in com 6- with unobstructed or non-combusti-as an a wteda d P Technical ble obstructed ceiling construction as ante with this document, as well as defined and permitted by NFPA 13, as with the applicable standards of the well as a specific application listing for NFPA, in addition to the standards of Data use under concrete tees. any other authorities having jurisdiction. Failure to do so may impair the perfor- Approvals Series EC-11 and EC-14 Extended Cov- mance of these devices. TYCO Series EC-11 and EC-14 erage Sprinklers have been fire tested The owner is responsible Extended Coverage Upright and for main to compare their performance to that P Pendent Sprinklers are UL and C-UL of standard coverage spray sprinklers. taining their fire protection system Listed. Refer to Table A for complete These tests have shown that the pro- and devices in proper operating con- sprinkler approval information including dition. Contact the installing contrac- tectio effective provided is equal to or more corrosion-resistant status.The approv- than standard coverage spray tor or product manufacturer with any als apply to the service conditions indi- sprinklers. questions. cated in the Design Criteria section. Sprinkler Series EC-11 and EC-14 Extended Cov- erage Sprinklers are FM Approved. Identification Refer to Table A for complete sprinkler IMPORTANT approval information including corro- Refer to Technical Data Sheet Numbers sion-resistant status. The approvals TFP2300 for warnings pertaining to apply to the service conditions indi- regulatory and health information. TY5137 Upright, 11.2K cated in the Design Criteria section. Always refer to Technical Data TY5237 Pendent, 11.2K The Style 60 Two-Piece Flush Escutch- Sheet TFP700 for the "INSTALLER TY6137 Upright,14.0K eon (Figure 4)is UL Listed for use with WARNING" that provides cautions TY6237 Pendent, 14.0K the Series EC-11 and EC-14 Pendent Sprinklers. with respect to handling and instal- TY5137 is a re-designation for C5137,G1894,and S2510 lation of sprinkler systems and corn- TY5237 is a re-designation for C5237,G1893,and 62511 Maximum Working Pressure Improper and TY6137 Is a re-designation for C6137,G1896,and 82610 175psi(12,1 bar) ponents. handling TY6237 is a re-designation for C6237,G1895,and 82611 installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail 3/4 in. NPT to operate in a fire situation or cause it to operate prematurely. 1 Page 1 of 8 AUGUST 2018 TFP220 . .. , - .y-\^ .-' c)-�T TFP220 Page 2 of 8 , WRENCH 3/4" ESCUTCHEON PLATE Components: FLAT NPT** SEATING SURFACE 1 1 - Frame 2 Button r lil ��\�, 1 2 3 Sealing Assembly - 4 Bulb 5 - Compression Screw II L illii %`" 6 Deflector* 2 7/16" �Ik _ `tip 3 UPR GHT& 'IWO i *Temperature rating is PENDENT 1-11/16" 1 q indicated on Deflector.(42,7 mm) \ I i I **Pipe thread connections per ;1� 5 ISO 7-1 can be provided on special request. 1/2"(12,7 mm) _._. .A i= 6* NOMINAL MAKE-IN CROSS UPRIGHT PENDENT SECTION FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR UPRIGHT(TY5137)AND PENDENT(TY5237) 14.0 K-FACTOR UPRIGHT(TY6137)AND PENDENT(TY6237) ASSEMBLY Discharge Coefficients UL and C-UL 4. To prevent cold soldering, the K= 11.2 GPM/psi' (161,3 LPM/bars) Listing Requirements minimum allowable spacing be- K= 14.0 GPM/psi'/=(201,6 LPM/bars) 1. Series EC-11 and EC-14 Extended tween Series EC-11 and EC-14 Ex- Temperature Ratings Coverage Sprinklers may be used tended Coverage Sprinklers is 8 ft Refer to Table A for the coverage areas shown in (2,4 m)for upright sprinklers and 9 ft Table D, based on maintaining the (2,7 m)for pendent sprinklers. Finish minimum specified flow rate as a 5. Series EC-11 and EC-14 Extended Sprinkler: function of coverage area and haz- Coverage Sprinklers are to be in- Refer to Table A and group for all sprinklers in the stalled in accordance with all oth- Recessed or Flush Escutcheon: design area. er requirements of NFPA 13 for • White-Coated, Chrome-Plated, and 2. Series EC-11 and EC-14 Extended extended coverage upright and Brass-Plated Coverage Sprinklers are permitted pendent sprinklers; For exam- to be used with unobstructed or ple, obstructions to sprinkler dis- Physical Characteristics me Bronze non-combustible obstructed ceil- charge, obstructions to sprinkler Button Bronze ing construction as defined and pattern development, obstructions Sealing Assembly . Beryllium Nickel w/TEFLON permitted by NFPA 13;for example: to prevent sprinkler discharge from Bulb Glass(3 mm) . Unobstructed, combustible or reaching hazard and clearance to Compression Screw Bronze storage. Deflector Brass noncombustible, ceiling con- struction with a deflector to UL and C-UL Specific Application Operation ceiling/roof deck distance of Listing Requirements for 1 to 12 in. (25 to 300 mm). Installation under Concrete Tees The glass bulb contains a fluid that • Obstructed, non-combusti- Series EC-11 and EC-14 Extended Coy- expands when exposed to heat.When ble, ceiling construction with a erage Upright and Pendent Sprinklers the rated temperature is reached, the deflector location below struc- (TY5137,TY5237,TY6137 and TY6237) fluid expands sufficiently to shatter tural members of 1 to 6 in. have a UL and C-UL Specific Applica- the glass bulb, which-then allows the (25 to 150 mm) and a maximum tion Listing for use under concrete tees sprinkler to activate and flow water. deflector to ceiling/roof deck dis- when installed as follows: tance of 22 in. (550 mm). 1. Stems of the concrete tee con- Design 3. Series EC-11 and EC-14 Extended struction must be spaced at less Coverage Sprinklers, specifically than 7.5 ft (2,3 m) on center but Criteria tested and listed for non-combus- more than 3 ft(0,9 m)on center.The tible obstructed construction, are depth of the concrete tees must not TYCO Series EC-11 and EC-14 exceed 30 in. (762 mm). The maxi- Extended Coverage Upright and Permitted to be used within truss- mumpermitted concrete tee length Pendent Sprinklers must onlybe es or bar joists having non-cam- t p bustible web members greater is 32 ft(9,8 m). However, where the installed in accordance with the appli- than 1 in. (25.4 mm) when apply concrete tee length exceeds 32 ft cable UL and C-UL Listing or FM ing the 4 times obstruction crite (9,8 m), non-combustible baffles, Approval requirements as indicated ria rule defined under "Obstruc_ equal in height to the depth of the below. Only Style 30 or 40 Recessed tions to Sprinkler Discharge Pattern tees, can be installed so that the Escutcheons are to be used for Development". space between the tees does not recessed installation, as applicable. exceed 32 ft(9,8 m)in length. Refer to Tables A, B, and C, for more information. TFP22O Page 3 of 8 Bulb Sprinkler Finish° Hazard Type Temperature Liquid Natural Chrome b Lead Brass Plated Polyester Coated 135°F(57°C) Orange Upright K=11.2(TY5137) 155°F(68°C) Red 1,2,3c,4 Light Pendent 175°F(79°C) Yellow K=11.2(TY5237) 200°F(93°C) Green Table B describes K=14.0(TY6237) 1,2,4 UL and C-UL 286°F(141 °C) Blue Sensitivity Rating 135°F(57°C) Orange 1,2,3,4 Table C describes Recessed Pendent 155°F(66°C) Red FM K=11.2(TY5237) Sensitivity Rating K=14.0(TY6237) 175°F(79°C) Yellow With Style 30 Escutcheon 200°F(93°C) Green 1,2,4 N/Ad 286°F(141 °C) Blue Upright 135°F(57°C) Orange K=11.2(TY5137) 155°F(68°C) Red Ordinary K=14.0(TY6137) 175°F(79°C) Yellow 1,2,3,4 Pendent Table B describes K=11.2(TY5237) 200°F(93°C) Green UL and C-UL K=14.0(TY6237) P86°F(141 °C) Blue Sensitivity Rating Table C describes Recessed Pendent 135°F(57°C) Orange FM K=11.2(TY5237) 155°F(68°C) Red Sensitivity Rating K=14.0(TY6237) 1,2,4 NIA 175°F With Style 30 or 40 (79°C) Yellow Escutcheon 200°F(93°C) Green NOTES 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL) 3. Approved by Factory Mutual Corporation(FM) 4. Approved by the City of New York under MEA 177-03-E a. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed as Corrosion Resistant Sprinklers. - b. Frame and Deflector only c. Pendent only d. N/A=Not available TABLE A LABORATORY LISTINGS AND APPROVALS Light Hazard Ordinary Hazard Area Style ft x ft 135°F 155°F 175°F 200°F 286°F 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141 °C) (57°C) (68°C) (79°C) (93°C) (141 °C) Upright or Pendent - - - - - OR QR QR OR QR 14 x 14 Style 30 Recessed - - - - - QR QR QR OR OR Style 40 Recessed - - - - - OR QR OR QR QR Upright or Pendent QR QR QR QR QR SR SR SR SR SR 16 x 16 Style 30 Recessed QR QR QR QR QR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent QR QR QR QR QR SR SR SR SR SR 18 x 18 Style 30 Recessed QR QR OR OR QR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR Upright or Pendent QR QR QR SR SR SR SR SR SR SR 20 x 20 Style 30 Recessed QR QR OR SR SR SR SR SR SR SR Style 40 Recessed N/A N/A N/A N/A N/A SR SR SR SR SR NOTES • QR=Quick Response • SR=Standard Response • QR and SR does not apply to Upright K=14.0 • Refer to Table D for permitted K-Factor/Area Combinations. TABLE B SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS TFP22O Page 4 of 8 HC-1 Linear Spacing Area Spacing ft ft Ceiling Height ft Ceiling Type K-factor Style Response Min Max Min Max Noncombustible Unobstructed, 11.2 EC Pendent or 10 20 100 400 Up to 30 Noncombustible Obstructed,or 14.0 EC Upright Combustible Unobstructed Noncombustible Unobstructed, 11 2 EC Pendent 10 20 100 400 Up to 30 Noncombustible Obstructed,or 14.0 EC Recessed Combustible Unobstructed Style 30 10 20 100 400 Up to 30 Combustible Obstructed 11.2 EC Pendent or 14.0 EC Upright Quick 11.2 EC Pendent 10 20 100 400 Up to 30 Combustible Obstructed 14.0 EC Recessed Style 30 10 20 100 400 Over 30 and Noncombustible Unobstructed 11.2 EC Upright up to 45 14.0 EC HC-2 Linear Spacing Area Spacing ft ft Ceiling Height Ceiling Type K-factor Style Response ft Min Max Min Max 10 20 100 400 Up to 30 11.2 EC Upright 10 20 100 400 Up to 30 14.0 EC Pendent or Noncombustible Unobstructed, Upright Quick Combustible Unobstructed 10 16 100 256 Over 30 and 11.2 EC 14.0 Upright up to 45 EC HC-3 Linear Spacing Area Spacing ft ft Ceiling Height Ceiling Type K-Factor Style Response ft Min Max Min Max 10 16 100 256 Up to 30 11.2 EC Upright 10 20 100 400 Up to 30 14.0 EC Pendent or Noncombustible Unobstructed, Upright Combustible Unobstructed Quick 10 16 100 256 Over 30 and 11.2 EC, Upright up to 45 14.0 EC NOTES • The design for K 11.2 EC(K 160 EC)sprinklers should not include fewer than six sprinklers or have a design pressure of less than 12 psi(0,8 bar);similarly the design for K 14.0 EC(K 200 EC)sprinklers should not include fewer than four sprinklers or have a design pressure of less than 18 psi(1,2 bar). • For flow criteria,refer to FM Loss Prevention Data Sheet 3-26. • Refer to FM Loss Prevention Data Sheet 2-0 for permitted K-Factor/Area Combinations. TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-11 OR EC-14 SPRINKLERS 2. The sprinkler deflectors are to be FM Approval Requirements hydraulic design, ceiling slope, and located in a horizontal plane at or Series EC-11 and EC-14 Extended obstructions, minimum and maximum above 1 in. (25,4 mm) below the Coverage Upright and Pendent Sprin- allowable spacing, and deflector-to- bottom of the concrete tee stems. klers are to be installed in accor- ceiling distance. 3. When the sprinkler deflectors are dance with the applicable FM Loss p Prevention Data Sheet for limited use These criteria may differ from UL located higher than a horizontal in buildings of specific roof construc- and/or NFPA criteria. Therefore, the plane 1 in. (25,4 mm) beneath the tion and for the protection of certain designer should review and become bottom of the concrete tee stems, specific ordinary hazard (non-storage familiar with FM requirements before the obstruction to sprinkler dis- and/or non-flammable or combustible proceeding with design. charge criteria requirements of liquid) occupancies. Information pro- NFPA 13 for extended coverage vided in the FM Loss Prevention Data upright and pendent sprinklers Sheets relates to, but is not limited to, applies. • TFP220 . Page 5 of 8 Light Hazard Group I Group II Area 0.10 GPM/ft2 Ordinary Hazard Ordinary Hazard Description ft x ft 0.15 GPM/ft2 0.20 GPM/ft2 . GPM PSI GPM PSI GPM PSI 14 x 14 30 7.2 30 7.2 39 12.1 TY5137 16 x 16 30 7.2 39 12.1 51 20.7 (K-11.2)Upright 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 30 7.2 30 7.2 39 12.1 TY5237 16 x 16 30 7.2 39 12.1 51 20.7 (K=11.2)Pendent 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 14 x 14 N/A N/A 39 7.8 51 13.3 TY6137 16 x 16 N/A N/A 39 7.8 51 13.3 (K=14.0)Upright 18 x 18 N/A N/A 49 12.3 65 21.6 20 x 20 N/A N/A 60 18.4 80 32.7 14 x 14 37 7.0 39 7.8 51 13.3 TY6237 16 x 16 37 7.0 39 7.8 51 13.3 (K=14.0)Pendent 18 x 18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 NOTES • 1ft=0.3048m • 1 ft2=0.093 mz • 1 GPM=3.785 LPM • 1 psi=0.06895 bar • 1 GPM/ft'=40.74 mm/min TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS Installation Do not attempt to compensate for Apply the wrench recess of the appli- insufficient adjustment in an Escutch- cable sprinkler wrench (Figure 5 and 6) TYCO Series EC-11 and EC-14 eon Plate by under or over-tightening to the sprinkler wrench flats(Figure 1). Extended Coverage Upright and the Sprinkler. Re-adjust the position of Pendent Sprinklers must be installed the sprinkler fitting to suit. Care and in accordance with this section. Step 1. Install the sprinkler with the General Instructions deflector parallel to the mounting Maintenance Do not install any bulb-type sprinkler surface. Install pendent sprinklers in TYCO Series EC-11 and EC-14 if the bulb is cracked or there is a loss the pendent position; install upright from the bulb. With the sprin- sprinklers in the upright position. of liquid Extended Coverage Upright and Pendent Sprinklers must be maintained kler held horizontally,a small air bubble Step 2.After installing the Style 30,40, and serviced in accordance with this should be present.The diameter of the or 60 mounting plate(or other applica- section. air bubble is approximately 1/16 in. ble escutcheon)over the sprinkler pipe (1,6 mm) for the 135 °F (57 °C) to threads and with pipe-thread sealant Before closing a fire protection system 3/32 in.(2,4 mm)for the 286°F(141 °C) applied to the pipe threads, hand- main control valve for maintenance temperature ratings. tighten the sprinkler into the sprinkler work on the fire protection system fitting' that it controls, obtain permission to A leak-tight 3/4 in. NPT sprinkler shut down the affected fire protection I joint should be obtained by apply- Step 3. For upright or pendent sprin- systems from the proper authorities ing a minimum-to-maximum torque of klers, wrench-tighten using only the and notify all personnel who may be 10 to 20 ft-lb(13,4 to 26,8 N•m). Higher W-Type 3 (End A) Sprinkler Wrench. affected by this action. levels of torque may distort the sprin- For the pendent sprinkler installed kler inlet with consequent leakage or with Style 30, 40, or 60 Escutcheon, Sprinklers which are found to be impairment of the sprinkler. wrench-tighten the sprinkler using only leaking or exhibiting visible signs of the W-Type 22 Sprinkler Wrench. corrosion must be replaced. TFP220 Page 6 of 8 2-7/8" DIA. 2-7/8" DIA. _ 1/2t1/8" (73,0 mm) 1/2"(12,7 mm) 5/8t1/4" (73,0 mm) 3/4"(19,1 mm) (12,7*3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) (15,9t6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF f- (57,2 mm) FACE OF (57,2 mm) SPRINKLER 1/8" SPRINKLER 1/8" FITTING (3,2 mm) FITTING (3,2 mm) 7-4 iii , ____ SURFACE MOUNTING } \ /Mt MOUNTING } PLATE MOUNTING CLOSURE ! SURFACE PLATE CLOSURE 1-3/8"(34,9 mm) 1-3/8"(34,9 mm) 1-1/8"(28,6 mm) 7/8"(22,2 mm) FIGURE 2 FIGURE 3 SERIES EC-11 AND EC-14 RECESSED SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 IN. TOTAL ADJUSTMENT WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON STYLE 40 RECESSED ESCUTCHEON 2-7/8" DIA. "FITTING SIDE" (73,0 mm) TOWARDS SPRINKLER 2-1/4" DIA INTERNAL FITTING ~ DIMENSIONS OF (57,2 mm)IA STYLE 60 ESCUTCHEON ACCOMMODATE �\ CLASS 150 MALLEABLE FACE OF IRON REDUCING SPRINKLER FITTING: SPRINKLER FITTING WRENCH 3/8"(9,5 mm)ABOVE RECESS TO 1/8"(3,2 mm)BELOW MOUNTING u (END"A") MOUNTING SURFACE • 1/8" SURFACE _ ' '_ . (3,2 m) I FIGURE 5 W-TYPE 3 SPRINKLER ESCUTCHEON PLATE v— ��� - WRENCH SEATING SURFACE: I J Il 1/4"(6,4 mm)ABOVE CLOSURE 2-5/16"(58,7 mm) TO 1/2"(12,7 mm)BELOW l 3/4" NPT WRENCH MOUNTING SURFACE; kid' MOUNTING 1-13/16"(46,0 mm) RECESS 3/4"(19,1 mm)TOTAL PLATE ADJUSTMENT -----•-• FIGURE 4 — drill SERIES EC-11 AND EC-14 PENDENT SPRINKLER ASSEMBLY moo WITH 3/4 IN. TOTAL ADJUSTMENT 11111■STYLE 60 TWO-PIECE FLUSH ESCUTCHEON Automatic sprinklers must never be liquid from its bulb. Refer to the Instal- © ' 1 ~ painted, plated, coated, or other- lation section,for more information. 1 wise altered after leaving the factory. Frequent visual inspections are rec ) ' Modified sprinklers must be replaced. ommended to be initially performed Sprinklers that have been exposed to \ corrosiveproducts of combustion, but for corrosion resistant coated sprin- WRENCH klers, after the installation has been HEX have not operated,should be replaced if they cannot be completely cleaned completed,to verify the integrity of the FIGURE 6 corrosion resistant coating.Thereafter, W-TYPE 22 RECESSED by wiping the sprinkler with a cloth or annual inspections per NFPA 25 should by brushing it with a soft bristle brush. SPRINKLER WRENCH suffice; however, instead of inspecting Care must be exercised to avoid from the floor level,a random sampling damage to the sprinklers before, of close-up visual inspections should during, and after installation. Sprin- be made,so as to better determine the klers damaged by dropping, striking, exact sprinkler condition and the long wrench twist/slippage,or the like,must term integrity of the corrosion resistant be replaced.Also,replace any sprinkler coating, as it may be affected by the that has a cracked bulb or that has lost corrosive conditions present. • TFP220 Page 7 of 8 P/N 51 - XXX - X - XXX SIN SPRINKLER TEMPERATURE FINISH1 RATING 893 11.2K Pendent TY5237 1 NATURAL BRASS 135 135°F(57°C) 894 11.2K Upright TY5137 4 SIGNAL WHITE 155 155°F(68°C) (RAL9003) POLYESTER 895 14.0K Pendent TY6237 175 175°F(79°C) 6 JET BLACK(RAL9005) POLYESTER 896 14.0K Upright TY6137 200 200°F(93°C) 7 LEAD COATED 286 286°F(141 °C) 9 CHROME-PLATED 000 OPEN2 NOTES: 1. Escutcheon ordered separately. 2. OPEN Indicates the sprinkler assembly without glass bulb,button,and sealing assembly. TABLE E SERIES EC-11 AND EC-14 UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION The owner is responsible for the Limited Ordering inspection, testing, and maintenance of their fire protection system and Warranty Procedure devices in compliance with this doc- Wa ument, as well as with the applicable For warranty terms and conditions,visit Contact your local distributor for standards recognized by the Approval www.tyco-fire.com. availability. When placing an order, agency,such as NFPA standards of anyny in addition to indicate the full product name and Part authorities having Number(P/N). jurisdiction.Contact the installing con- tractor or product manufacturer with Sprinkler Assemblies with any questions. NPT Thread Connections Automatic sprinkler systems are rec- Specify: Series EC 11 or EC-14 ommended to be inspected, tested, (specify) Sprinkler, SIN (specify), and maintained by a qualified Inspec- (specify) K-factor, Pendent or Upright tion Service in accordance with local (specify)Extended Coverage,(specify) requirements and/or national codes. temperature rating,(specify)finish, P/N (from to Table E) Recessed Escutcheon,Two-Piece Specify: Style (30 or 40) Two-Piece Recessed Escutcheon with (specify) finish, P/N (specify*) "Refer to Technical Data Sheet TFP770 Flush Escutcheon,Two-Piece Specify: Style 60 Two-Piece Flush Escutcheon with (specify) finish, P/N (specify") "Refer to Technical Data Sheet TFP778 Sprinkler Wrenches Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 Specify:W-Type 22 Recessed Sprinkler Wrench, P/N 56-665-7-001 • TFP220 Page 8 of 8 • • 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362.0700 02018 Johnson Controls.All rights reserved All specifications and other information shown were current as of document revision elate and are subject to change without notice. Johnson ))1�(i NATIONAL FIRE PROTECTION ASSOCIATION and NFP0.are registered trademarks 01 National Flre Protection Ansecietlon', Controls TEFLON Is a registered trademark of!NNW