Loading...
Report S242o -000 9 t , t 02bb aree.nbv% tt . l os o lLU HVE1 B®SimplEx TrueA/ert Multi-Candela Notific8ltiion Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances Ikul.1 I 'hiintitred Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSynt * •- . iRWL§PtPatible Features Visible only(VIO) 24 VDC notification appliances ,+ 3 with high output xenon strobe,available for wall } ; ' j " or ceiling mount: i :tri• • Intensity is selectable as 15,30,75,or 110 candela with °^° visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements(refer ` `:""' t1:> ' r °` '" tRltt to important installation information on page 3) x , • Polarized input allows connection to compatible reverse = _ polarity,supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output Wall Mount Strobes and provides controlled inrush current • Rugged,high impact,flame retardant thermoplastic . IE ( FIRE I housings are available in red or white with clear lens i 1r • Listed to UL 1971 and ULC S526 '',,-- - Strobes provide synchronized flash for use with: =— — • Simplex®fire alarm control panels with NACs selected Ceiling Mount Strobes to provide strobe synchronization or SmartSync • two-wire control Descrl'tion • 4009 IDNet NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes.The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output,on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible,easy, and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box.The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection,and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation,a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity.An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975-9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes* Proper selection of visible notification is dependent on occupancy,location, local codes,and proper applications of:the National Fire Alarm Code(NFPA 72),ANSI • Refer to page 2 for guard listing.This product has been approved by the California State A 1 17.1;the appropriate model building code:BOCA, Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety ICBO,or SBCCI;and the application guidelines of the Code.See CSFM Listing 7125-0026316 for allowable values and/or conditions concerningpP g material presented in this document.Refer to page 2 for listing status of wire guards. Americans with Disabilities Act(ADA). Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4906-0001-5 11/2014 Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their SmartSync two-wire control is available from: • reflections can be seen from one location,synchronized • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, flashes reduce the probability of photo-sensitive reactions and 4100U Fire Alarm Control Panels(refer to as well as the annoyance and possible distraction of individual product data sheets for more information) random flashing.These multi-candela strobes are • 4009 IDNet NAC Extenders(refer to data sheet synchronized over a two-wire circuit when connected to S4009-0002) compatible NACs,to compatible Synchronized Flash • SmartSync Control Module(SCM)Model 4905-9938 Modules,or to SmartSync Control Modules. (refer to data sheet S4905-0003) SmartSync Two-Wire Control Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the alarm condition is reset(on-until-reset). SmartSync operation mode provides this function using a single circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances(Strobes) Model Mounting Housing Color "FIRE"Lettering Description ,4(?410.t11- Wall Red White 4906-9103 White Red Multi-candela strobe with intensity selectable as: • 15,30, 75,or 110 candela;synchronized flash rate; 4906-9102 Red White SmartSync two-wire control compatible 4906-9104 Ceiling White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm) 5-3/8"H x 5-1/4"W x 1-5/8" D (136 mm x 133 mm x 41 mm) 4905-9940 White deep surface mounted boxes Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7 7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate;zinc plated;required for mounting to 4-7/8"x 3-1/8"x 0.060"D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16" in/out 18 AWG(0.82 mm2)wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"Wx 1-1/2"D For Wall mount strobes 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 6-1/16"H x 6-1/16"Wx 3-1/8" D 4905-9961" Wall mount Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) semi-flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep 4905-9926" Ceiling mount (156 mm x 111 mm x 73 mm) "UL listed by Space Age Electronics Inc. 2 S4906-0001-5 11/2014 - Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%, non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd I 110 cd Wall Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4" L x 2-5/16"Wx 2-5/8"D(121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with f '. o \OI single gang,double gang,and I 1 I 4"(102 mm)square boxes, 1-1/2"(38 mm)deep,by others iI! Ii-•i ig<O7 _� t01 _ IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens O Ot Q OP fj is either even with,or slightly Electrical Wiring access hole 11117,1�C� above bottom box outline c ® \ of compatible •I u � L 1 boxes Wiring terminals " :*#677-4,1 7— I1 Mounting Holes: 4"square(4) NFPA 72 requires 80"(2.03 m) '0.'m0'aQ rgeogiost IIJ Single gang(2) that the entire lens minimum TiI Double gang(3) be not less than 1111111/1r 80"and not greater than 96"above the finished floor Transparent housing and lens assembly Intensity selection plug,accessible only irli ® fromof rear of housing; 11 n IE factory setting is 15 cd all Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference Handy box,1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang V57445)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others Also can be attached to boxes /(,r ,{// mounted to drop ceiling T-bar with clips(ERICO No.512 or equal) 0 0 4905-9910 Adapter Plate,required for surface mount with handy box unless using the 4905-9926 wire guard I. I i -I Ceiling mount strobe R i Optional 4905-9926 wire guard II'�II fI0 II�II with mounting plate Illj i , ,� Strobe intensity 114/4 ILri, viewing slot WI udi Intensity selection plug, accessible only from rear of lens housing;factory setting is 15 cd L Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt Amismir and Optional Wire Guard -_t�7 Surface mount conduit and 0 ill box shown for reference ------ --- 4' (102 mm)square FuI i =6� �-+•-• mw• box profile, 1-1/2" I,II' I�•■I_I—I—I_I-i� (38 mm)deep lil11�1■I�Irl1ll II _l:l�: OptionalI, 1�� �� I O O I 4905-9961 ©� I Wire Guard IFLLwD_. I Strobe 4,=r11� _2r� n� ,�• • , U-' ° 11UE ILL=�I_I _l 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO.SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NEPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association/NFPA). Ei,S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0001-5 11/2014 www.simplex-fire.com 2014 1 yea hire Protection Products.All rights reserved All specifications and other information shown were current as of-document revision dale and are subject to change without notice. RECENc nn EtSimplex TrueA/ert Multi-Candela Notification Appal tees MAR18non UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances wit hronlz Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSyne Bf oklt Rpatible Ior1 Features Visible only (V/O)24 VDC notification appliances 4 w: z, with high output xenon strobe, available for wall or ceiling mount: • Intensity is selectable as 15,30,75,or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements(refer to important installation information on page 3) • Polarized input allows connection to compatible reverse e"s polarity, supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output Wall Mount Strobes and provides controlled inrush current • Rugged,high impact,flame retardant thermoplastic ;^ FIRE I FIRE f housings are available in red or white with clear lens • Listed to UL 1971 and ULC S526 _ %( ,.._. • Strobes provide synchronized flash for use with: • Simplex®fire alarm control panels with NACs selected Ceiling Mount Strobes to provide strobe synchronization or SmartSync two-wire control Descri.tion • 4009 1DNet NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output,on-site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy,and accommodated. convenient semi-flush or surface wall mounting: Wall mount strobe housings are a one-piece assembly • Rear of housing does not extend into box (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box.The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes.Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection,and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation,a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity.An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975-9145 boxes Strobe Application Reference • UL listed red wire guards are available for wall or ceiling mount strobes* Proper selection of visible notification is dependent on occupancy,location,local codes,and proper applications of:the National Fire Alarm Code(NFPA 72),ANSI • Refer to page 2 for guard lishng.This product has been approved by the California State A117.1;the appropriate model building code:BOCA, Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety 1CBD,or SBCCI;and the application guidelines of the Code.See CSFM Listing 7125-0026.316 for allowable values and/or conditions concerning material presented in this document.Refer to page 2 for listing status of wire guards. Americans with Disabilities Act(ADA). Additional listings may be applicable;contact your local Simplex product supplier for the latest status,Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products, S4906-0001-5 11/2014 Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their SmartSync two-wire control is available from: reflections can be seen from one location,synchronized • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, flashes reduce the probability of photo-sensitive reactions and 4100U Fire Alarm Control Panels(refer to as well as the annoyance and possible distraction of individual product data sheets for more information) random flashing.These multi-candela strobes are • 4009 IDNet NAC Extenders(refer to data sheet synchronized over a two-wire circuit when connected to S4009-0002) compatible NACs,to compatible Synchronized Flash • SmartSync Control Module(SCM)Model 4905-9938 Modules,or to SmartSync Control Modules. (refer to data sheet S4905-0003) SmartSync Two-Wire Control Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the alarm condition is reset(on-until-reset). SmartSync operation mode provides this function using a single circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances(Strobes) Model Mounting Housing Color "FIRE"Lettering Description > 4906-9101 Wall Red White 4906-9103 White Red Multi-candela strobe with intensity selectable as: 15,30,75,or 110 candela;synchronized flash rate; 4906-9102 Red White SmartSync two-wire control compatible 4906-9104 Ceiling White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red 5-3/8"H x 5-1l4"W x 1-5/8"D Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm) deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x 3 x D (200mmx 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate;zinc plated; required for mounting to 4-7/8"x 3-1/8"x 0.060"D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with 1-3/8"x 2-7/16"x 13/16" in/out 18 AWG(0.82 mm2)wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905-9922 Class A requires 5 mA for power 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D For Wall mount strobes 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) semi-flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep 4905-9926* Ceiling mount (156 mm x 111 mmx 73 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0001-5 11/2014 • . Strobe Specifications Wall Mount or Ceiling Mount, Common Specifications . Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%, non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with d r \ o ( \ I� single gang,double gang,and 1 1 4"(102 mm)square boxes, 1-1/2"(38 mm)deep,by others �t77 _I ant _ Alr IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE iI. iI ,1 Bottom of lens �� � is either even _ QUP Electrical (� with,or slightly Wiring access hole t lO ■C_ �'� above bottom box outline i =[p]® `NAil of compatible �����_!p� boxes Wiring terminals ' '`'e At- li ILga hMounting Holes. i, iu 4"square(4) NFPA 72 requires 80"(2.03 m) Single gang(2) that the entire lens minimum reirprAv Double gang(3) be not less than ilI�I�� 80"and not greater than 96"above the Transparent housing finished floor and lens assembly - Intensity selection plug,accessible only FM® from rear of housing, �'S [ Ii IE factory setting is 15 cd alli Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-5 11/2014 • - Ceiling Mount Strobe Installation Reference Handy box,1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others • Also can be attached to boxes A /./ mounted to drop ceiling T-bar with clips(ERICO No.512 or equal) ICD CD 4905-9910 Adapter Plate,required for (using surface mount with handy box unless o the 4905-9926 wire guard I- l I -I _. RR F _ Ceiling mount strobe k II �I'�II �IU °YI= I_hI!PIIOptional 4909p9926wireguardI _ with mountin late .1`� Strobe intensity INwritili:16- viewing slot accesibl a myfr mplue, taccessible only from rear of lens housing;factory setting is 15 cd L Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference Amiimpir 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard --j Surface mount conduit and - box shown for reference 0 -•—•—• 4"(102 mm)square (♦ICI �y7:l� ::l.� ---,-• box profile, 1-1/2" 11111111 I1,'I.I.I.lI'II I II I (38 mm)deep MIME I�uI I..I O O Optional ��� I 4905-9961 II' JI Wire Guard _ I III Strobe �\� / `�I'L IM: R=,I1 IF L-I_I _l 4905-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCQ SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited NEPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NEPA). £;®S i m p I Ex Tyco Fire Protection Products•Westminster, MA•01441-0001•USA S4906-0001-5 11/2014 www.simplex-fire.com 20 T1 Tyco Fire Protection Products.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice