Loading...
Report • OFFICE COPY - - E-11 ifs 1 = _ QrrYpfl.k I?al FIRE SPRINKLER PRODUCT SUBMITTAL 1 1 H 411 FOR: Tigard Triangle nd 8vkt._72 __aff1sjiv_Eta)/Ior St. Tigard, OR 97223 ir:+ c DATE: 06-01-2020 fim HI , SUBMITTED BY: ro n t ire yste s Inc 7402 SE JOHNSON CREEK BLVD. PORTLAND, OREGON 97206 PHONE NO. (503)777-5030 FAX NO. (503)777-0659 4077 Airpark Dr.Standish, MI 48658•989-846-4583•www.globesprinkler.com 434 Technical Support•989-414-2600•techservice@globesprinkler.com SERIES GL-RES RESIDENTIAL PENDENT AND RECESSED PENDENT K-FACTOR: 3.0, 4. 1, 4.9, 5.6 GENERAL DESCRIPTION The series GL-RES pendent sprinklers are decorative fast K k response glass bulb sprinklers specifically tested and List- ed for use in residential applications such as homes, apart- it . ments, hotels, and dormitories to provide control of these ` residential type fires and to improve the chance for occu- pants to escape. They utilize a 3mm frangible glass bulb as its heat sensing operating element. The recessed version of each of these Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Re- SERIES GL-RES cessed Escutcheon. The Recessed Escutcheon provides a GL3010, GL4110, GL4910, GL5610 total adjustment of 1/2 inch (12.7mm)from the flush ceiling position or±1/4 inch (6.4mm) of recessed adjustment. The TECHNICAL DATA adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must Approvals be cut. • See TABLE A This sprinkler may be installed within dwelling occupancies Maximum Working Pressure as allowed by NFPA 13, 13D, 13R and any other related • 175 psi (12 bar) documents as appropriate. Temperature Rating The GL3010 is typically utilized when maximum coverag- ' See TABLE A K-Factor es are not needed, thereby reducing flow demands. The • /Z '/z GL5610 is typically the sprinkler of choice when utilizing • GL3010 K3.0 gpm/psi1/2 (43.2 Ipm/barn) Residential Sprinklers within an NFPA 13 Occupancy. The GL4110 K4.1 gpmlpsi� (59.0 Ipm/bard) larger K-factor can be advantageous when needed to con- • GL4910 K4.9 gpm/psi , (70.6 Ipm/barz) • form to the NFPA 13 hydraulic Special Design Approach for GL5610 K5.6 gpm/psi (80.6 Ipm/bar ) Residential Sprinklers. Thread Size • 1/2" NPT(15 mm) Length • 2-1/2" (6.3 cm) Materials of Construction OPERAT/ON • Frame- bronze • Deflector-brass•Screw-brass Upon exposure to heat such as from a fire, the fluid in the • Lodgement Wire (GL5610 only)-stainless steel • Bulb bulb expands, compressing the air bubble within the bulb. seat-copper When the air bubble can no longer compress, the fluid ex- ' Spring- nickel alloy• Seal -teflon pansion causes breakage of the glass bulb, resulting in re- • Bulb glass with alcohol based solution, 3mm lease of the water seat assembly, and discharge of water ' Escutcheon Assembly-carbon steel from the sprinkler. FINISHES AND ACCESSORIES Finishes • Factory Bronze •Chrome•White Polyester NOTE: • Black Polyester-special order Users should refer to Globe's web site (www.globesprinkler.com) Escutcheons to assure that the most recent technical literature is being utilized. Brass• Chrome•White Polyester•Black Polyester Wrenches • Standard• Recess•1/2"NPT APRIL 2019 REV.A GFS-302 PAGE 1 of 4 DESIGN CRITERIA The Globe Residential Pendent Sprinkler Series GL-RES is Hydraulic Design (NFPA 13) cULus Listed for installation in accordance with this data The minimum required discharge from each design area sheet as well as the applicable installation Standard being sprinkler shall be the greater of the following: utilized. (1) In accordance with minimum flow rates indicated in Globe Residential Sprinkler Installation Guide TABLE A. (2) In rooms or compartments greater than 800 ft2 When conditions exist that are outside the scope of the pro- (74.3 m2), calculated based on delivering a minimum vided criteria, refer to the Globe Residential Sprinkler Instal- of 0.1 gpm/ft2 (4.1 mm/min)over the coverage area of lation Guide (Document GFS-380) for recommendations each sprinkler, calculated in accordance with the that may be acceptable to the authority having jurisdiction. S x L Rules for density area sprinklers. Hydraulic Design (NFPA 13D and 13R) (3) In roams or compartments 800 ft2(74.3 m2)or less (Defined as"Small Rooms")calculated based on de- For systems designed to NFPA 13D or NFPA 13R, the min- livering a minimum of 0.1 gpm/ft2(4.1 mm/min)over imum required sprinkler flow rate is given in Table A for the the room or compartment using the area of the room coverage areas shown. The sprinkler flow rate is the min- divided by the number of sprinklers in the room. (7psi imum required discharge from each of the total number of minimum) "design sprinklers"as specified in NFPA 13D or NFPA 13R. TABLE A: NFPA 13, 13R, AND 13D HYDRAULIC AND INSTALLATION DESIGN CRITERIA DEFLECTOR TO MINIMUM K TEMPERATURE MAX.AREA OF MINIMUM MINIMUM CEILING/ DISTANCE SIN FACTOR COVERAGE PRESSURE FLOW MOUNTING BETWEEN ca ,Ps.; FEET(mi PS1(bar) GPM(vmim) SURFACE SPRINKLERS (?mr�o)r'') DISTANCE 155"F 175T 200'F INCFEET(rn/ (68"C) (79°C) (93°C) hEs(rnm) cULus cULus cULus 12(3.6)x 12(3.6) 7.1 (.49) 8.0(30.3) 3.0 Elio) GL3010 (43.2) cULus EUI'I cULus cULus 14(4.3)x 14(4.3) 11.1 (.765) 10.0(37.8) cULus cULus Elio) EUI'I NA 12(3.6)x 12(3.6) 7.2(.5) 11.0(42) Smooth Ceilings 4.1 cULus Recessed GL4110 (59) EUUS NA NA 14(4.3)x 14(4.3) 8.6(.59) 12.0(45) 1-1/8(29) to 1-5/8(41) cULus Elio) cULus NA 16(4.9)x 16(4.9) 11.7(.81) 14.0(53) Smooth Ceilings cULus cULus Exposed EUI'I EUI'I NA 12(3.6)x 12(3.6) 7.0(.48) 13.0(49) Max.4(101.6) cULus EU('S EUm'S NA 14(4.3)x 14(4.3) 8.2(.57) 14.0(53) Beamed Ceilings Adjacent 8(2.4) 4.9 cULus cULus per NFPA 13, 13D, GL4910 (70.6) aimEUI'I NA 16(4.9)x 16(4.9) 8.2(.57) 14.0(53) or 13R as appropriate cULus cULus EUI'I EU`'I NA 18(5.5)x 18(5.5) 12.0(.83) 17.0(64) Beamed Ceilings cULus cULus In Beam aim Elio) NA 20(6.1)x 20(6.1) 16.7(1.15) 20.0(76) 14"Max.Beam Depth 1-1/8(29) cULus NA NA 12(3.6)x 12(3.6) 7.2(.5) 15.0(57) to 1-5/8(41) 5.6 cULus NA NA 16(4.9)x 16(4.9) 11.5(.79) 19.0(72) GL5610 (80.6) cULus NA NA 18(5.5)x 18(5.5) 14.1 (.97) 21.0(79) cULus NA NA 20(6.1)x 20(6.1) 18.4(1.27) 24.0(91) NOTE: Deflector-to-Ceiling Distance Criteria reflects 2019 Edition of NFPA 13D and 13R. O'LISTED BY UNDERWRITERS LABORATORIES,INC.FOR USE IN THE U.S.,CANADA, AND EUROPEAN UNION. APRIL 2019 REV.A GFS-302 PAGE 2 of 4 • INSTALLATION NOTICE Do not install any bulb-type sprinkler if the bulb is cracked or there is loss of liquid from the bulb. Sprinklers should be tightened t• ,' enough to obtain a leak-tight joint when water pressure is applied and/or hydrostatic test is performed. Sprinklers should not be ny - overtightened as this can result in distortion and subsequent leak- age. It is recommended not to exceed 14 ft.-lb. (19.0 Nm) torque FIGURE 1: STANDARD WRENCH for 1/2 inch NPT sprinkler threads. P/N 325390 Step1. Sprinklers must be properly oriented. Step2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprin- kler fitting. Note:Do not grasp the sprinkler by s = the deflector. " ' Step3. Wrench-tighten the sprinkler using only the , appropriate wrench.Wrenches are only to be applied to theisprinkler wrench flats or wrench hex as applicable. Note: Do not apply wrench to FIGURE 2: RECESSED WRENCH frame arms. P/N 325391 CARE AND MAINTENANCE Prior to installation, it is important to read and follow the "Sprinkler Caution" sheet (GFS-840) included within each box of sprinklers. This sheet is available on Globe's web site (www.globesprinkler.com). Always obtain permission from the proper authorities to 215116°oA shut down the affected fire protection system and notify all personnel who may be affected by this action before closing HOLE MIN CEILING a fire protection system main control valve for maintenance - 29132•DIA. work on the system that it controls. Sprinklers should only be cleaned by means of gently dust- ing with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. 1.x,a"REDUCER ` Store sprinklers in a cool, dry place. Exposure to extremeIY ACE OFFTG. heat will damage the thermal sensing element, possibly re- ,� = 1 d� ` RMIN. suiting in premature activation.Avoid direct sunlight -411 � . ,1�j �° ,n Replace any sprinkler that shows any corrosion, damage, CNR I I L8. CEILING or loss of liquid from the glass bulb. IV MIN(REF RETAINER ,5/8'MAX.(REF.) Do not attempt to paint or alter the sprinkler's coating in any manner after leaving the manufacturing plant. ----- • (INNER RETAINER FLUSH WITH CEILING) Do not attach wiring, ropes, decorations or fixtures to a sprinkler. FIGURE 3: 1/2"ADJUSTMENT RECESSED PENDENT Absence of an escutcheon, used to cover a ceiling hole, may delay sprinkler operation in a fire situation. It is the owner's responsibility for inspection, testing and maintenance of the fire sprinkler system with all components and devices in accordance with the National Fire Protection Association Pamphlet 25 as well as any other requirements as set forth by the local Authority Having Jurisdiction (AHJ). 4077 Airpark Dr.Standish, MI 48658•989-846-4583•www.globesprinkler.com Technical Support•989-414-2600•techservice@globesprinkler.com APRIL 2019 REV.A GFS-302 PAGE 3 of 4 ORDERING INFORMATION TABLE B: PART NUMBER SELECTION PART NUMBER SIN + TEMPERATURE + FINISH XXXX XXX XX SIN TEMPERATURE FINISH GL3010 i 3010 i 155 155°F(68°C) 01 BRONZE GL4110 4110 175 175°F(79°C) 02 CHROME GL4910 4910 200 200°F(93°C) 03 WHITE POLYESTER GL5610 5610 04 BLACK POLYESTER Note:All combinations may not be available. Refer to TABLE A for available listed combinations TABLE C: ESCUTCHEONS 1/2"(13mm)ADJUSTABLE RECESSED ESCUTCHEON FINISH FRICTION FIT 1/2"NPT THREADED 1/2"NPT Chrome 332071 329301 White Polyester 332073-W 329303-W • Brass 332072 NA Black Polyester 332073-0 NA SPECIFY: • SPRINKLER •Quantity•SIN•Temperature Rating•Finish •Part Number(See TABLE B) • ESCUTCHEON •Quantity•Finish• Part Number (See TABLE C) GLOBE® PRODUCT WARRANTY • WRENCH •Quantity•Part Number Globe agrees to repair or replace any of its manufactured 1/2"NPT Standard 325390 products found to be defective in material or workmanship 1/2"NPT Recess 325391 for a period of one year from date of shipment. • PROTECTIVE CAPS •Quantity•Part Number For specific details of our warranty please refer to Price List Cap 327109-Cap Terms and Conditions of Sale (Our Price List). APRIL 2019 REV.A GFS-302 PAGE 4 of 4 AUTOMATIC SPRINKLERS GL SERIES UPRIGHT 0 PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically " ' pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and 11 s is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that a contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal ' pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed 2 in an approved pattern depending upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL •See reverse side for Approvals and Specifications. SIDEWALL *Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) *Water Working Pressure Rating - 175 psi (12 Bars) , •Factory tested hydrostatically to 500 psi (34 Bars) •Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE •Frame - bronze • Deflector- brass • Screw- brass HORIZONTAL LPC/CE •Lodgement Wire - stainless steel • SIDEWALL HORIZONTAL •Bulb seat - copper • Spring - nickel alloy • Seal - teflon SIDEWALL •Bulb - glass with alcohol based solution, 3mm size ®SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 15E A: m ORANGE/RED S4e INIt moil EGIHft , p ?,,,i; wlvv.,?. . rcLLuvV1urcccIVViito.4,7:n: m. .. T IIOI I A. `DOT ,',1 a BLUE l-K L.3T ® ; '"'; 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 o FAX 989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV.#9 iLIICK1ESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT PENDENT S VERTICAL SIDEWALL HORIZONTAL SIDEWALL a CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.0 (30 . ,�LIL,) ./2" ur T 2 1,4" (5.7,....) 4.2 (33 „,..LL.) 1/2" rim- Y I/!" (5.7.,,,,) Factory Bronze Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 TM Olt ,,,..L:�) 1/2" Nr T 2 1/1" (L.7.....) Black Polyester 2.3 I.1 (11C ®e:e) 3n" NrT Q 7110" (0.2..,,,) METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". I FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD' 135°F 155°F 175°F 200°F 286°F cULus FM LPC CE NYC-DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X GL4215 4.2 LH X X X X X X — — — X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 7.8" LH/OH X X X X X X — — — X GL8118 8,1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8* LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — - - GL2826§ 2.8 LH X X X X X X — — — X HORIZONTAL GL4226§ 4.2 LH X X X X X X — — — X SIDEWALL GL5626§ 5.6 LH/OH X X X X X X X — — X GL5627o 5.6 LH/OH X X X X X — — X X — GL8127§ 8.1 LH/OH X X X X X X , — — — — CONVENTIONAL GL5624 5.6 LH/OH X X X X X — — X X — (OLD STYLE) GL8125 8.1 LH/OH X X X X X — — X X — 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6"BELOW THE CEILING. rlINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. 1PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6'MIN.SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD "1/2"NPT ORDERING INFORMATION GLOBE®PRODUCT WARRANTY SPECIFY •Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured "Orifice • Thread Sizes • Temperature products found to be defective in material or workmanship for a •Finishes desired period of one year from date of shipment. •Quantity-Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List PIN 312366 (L.O.) Terms and Conditions of Sale (Our Price List). - -� 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 FIRE ## 1 LE C RPO AT6t9 1-800-248-0278 www.globesprinkler.com JUNE2012 PRINTED U.S.A. BULLETIN GL5615,REV.#9 CkiF � ��t� r 4077 Airpark Dr.Standish, MI 48658 •989-846-4583•www.globesprinkler.com ARE SPRINKLER CORPORATION Technical Support•989-414-2600•techservice@globesprinklercom SPECIFIC APPLICATION MODEL "IC" INTERSTITIAL COMBUSTIBLE CONCEALED SPACE UPRIGHT SPRINKLER GL5608 GENERAL DESCRIPTION The Globe Model "IC" GL5608 Interstitial Combustible Space Sprinkler is a quick response, upright, specific appli- cation sprinkler designed to provide protection of light haz- ard combustible and non-combustible concealed spaces. Each GL5608 sprinkler can be designed for up to 16ft x 16ft (4.9m x 4.9m) spacing, providing as much as 256 ft2 (23.8m2)of protection per sprinkler. The GL5608 sprinkler meets the requirements of Under- writers Laboratories UL 199H to comply with criteria for the protection of combustible concealed spaces as described in NFPA 13. • When heat is absorbed, liquid within the glass bulb ex- pands, increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an ap- MODEL "IC" UPRIGHT GL5608 proved pattern. APPLICATION The Model "IC" GL5608 can be designed for installation GLOBE MODEL "IC" UPRIGHT in CPVC wet pipe sprinkler systems and steel wet pipe or SPRINKLER: dry pipe sprinkler systems. The Model "IC" GL5608 can be used in concepled spaces having roof pitch of 2 in 12 or The Globe Model "IC" GL5608 Interstitial Combustible Up- less constructed of wood truss, non-combustible bar joist, right Sprinkler has been Listed to be used beyond the 36" solid wood joists, or composite wood joists. The specific de- (914.4mm) height to a height of 60" (1.5m)to provide more sign requirements for each type of piping system, and con- functionality in installation specifically in areas where the struction materials can be found in the following sections of height of the concealed space is both above and below the this document. height of 36" (914.4mm). NFPA 13 REQUIREMENTS TECHNICAL DATA Sprinklers shall be Listed for use in combustible concealed • cULus Listed for coverage areas up to 256 ft2(23.8 m2) spaces (with a slope not exceeding 2 in 12) with combus- • 16 ft(4.9 m)maximum and 6 ft(1.8 m) minimum tible wood truss, wood joist construction, or bar joist con- Sprinkler Spacing struction having a combustible upper surface and where the Maximum Open Space Height 60 in (1.5 m) depth of the space is less than 36" (914.4mm) from deck • Temperature Ratings- 175°F '79°C' 200°F (93°C) to deck or with double wood joist and composite wood joist construction with a maximum of 36"(914.4mm) between the • Finish - Factory Bronze top of the bottom joist and the bottom of the upper joist. • Water Working Pressure Rating - 175 psi (12 Bars) HYDRAULIC DESIGN AREA • (Maximum low temperature glass bulb rating-67°F 55 C) For all pipe and construction types the design area shall be • Materials of Construction, Frame- bronze, Deflector- 1000 ft2(92.9m2)except for Steel Pipe Systems with insula- brass, Screw- brass, Bulb seat-copper, Spring-nickel tion filled joists, the design area shall be in accordance with alloy, Seal -teflon, Bulb-glass with alcohol based the Light Hazard Systems requirements of NFPA 13. solution, 3mm size SPRINKLER COVERAGE AREA The coverage area of any single Model IC Sprinkler shall utilize the SxL rule for all sprinkler spacings (i.e. 16 x 10 = 160 sq.ft. X 0.10= 16 gpm). APRIL 2016 Page 1 of 6 GFS-600 (Formerly A-40) TABLE A GENERAL INSTALLATION ALLOWANCES STEEL PIPING CPVC PIPING OPEN SPACE HEIGHT TOTAL OPEN SPACE HEIGHT TOTAL COVERAGE DISTANCE CONSTRUCTION TYPE ALLOWED ALLOWED AREA BETWEEN SPACE SPACE Fee' SPRINKLERS MINIMUM MAXIMUM '.HEIGHT' MINIMUM MAXIMUM HEIGHT' (Meters') Feet(Meters) Inches(mm) Inches(mm) Inches(mm) Inches(min) Inches(mm) Inches(mm) Unobstructed Wood Truss 6(152) 60(1524) 60(1524) 6(152) 60(1524) 60(1524) Non-Combustible Bar Joist MINIMUM6( .8) Obstructed Wood Truss 256(78.0) 6(152) 60(1524) 84(2134) N/A N/A N/A MAXIMUM 16(4.9) Solid Wood Joist MAXIMUM Insulation Filled Joist 6(152) 60(1524) 72(1829)' 6(152) 60(1524) 72(1829)" NOTE:METRIC CONVERSIONS ARE APPROXIMATE. WHEN TRUSS OR JOIST SPACE IS NONINSULATION FILLED, THE MAXIMUM ALLOWED TOP MEMBER DEPTH IS 12`(305 mm). 2 UP TO 12"(305mm)LOWER MEMBER SPACE. TABLE B SPRINKLER SPECIFICATION AND APPROVALS TEMPERATURE RATING NOMINAL MAX.LOW STYLE SIN "K" HAZARD' THREAD` SPRINKLER FINISH PRESSURE TEMP BULB cULus MODEL FACTOR SIZE LENGTH 175°F 200°F RATING RATING (79°C) (93°C) UPRIGHT GL5608 5.6 LH 1/2"NPT 2 1/4" Factory X x 175 psi -67°F x (80 metric) (15mm) (5.7cm) Bronze (12 Bars) (-55°C) NOTE. METRIC CONVERSIONS ARE APPROXIMATE. 2 SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. OBSTRUCTION CRITERIA For systems where the Globe "IC" Upright Sprinklers are the Globe "IC" Upright Sprinkler must use the obstruction positioned with 15' (4.6m) or less between sprinklers the requirements for extended coverage upright sprinklers. Globe "IC" Upright Sprinkler must use the obstruction re- quirements for standard spray upright sprinklers. NOTE: For systems where the Globe "IC" Upright Sprinklers are ' WEB MEMBERS AND GUSSETS SHALL NOT BE CONSIDERED OB- STRUCTIONS PROVIDED THE MINIMUM 4-1/2 INCH LATERAL DISTANCE positioned with greater than 15' (4.6m) between sprinklers REQUIRED BY THE SPECIFIC APPLICATION LISTING IS MAINTAINED. CPVC DESIGN REQUIREMENTS SYSTEM TYPE PARTITION REQUIREMENTS The concealed space being protected must be broken up Wet pipe system. into areas no greater than 1000 square feet either by full height walls or by draft curtains. ALLOWABLE CONSTRUCTION DRAFT CURTAINS TYPES When draft curtains are used they must be 8" (203.2mm) • Unobstructed wood truss construction in height or one third of the depth of the concealed • Unobstructed bar joist construction' space, whichever is greater. Draft curtains must be o Non-combustible insulation filled solid wood joist constructed of a material that will not allow for heat to construction' escape through or above them. • Non-combustible insulation filled composite wood joist construction2 NOTE: UpperjoisUhuss cannot be more than 4"(101.6mm)in height. The joist space in non-combustible insulation filled joist construction must be completely filled with noncombustible insulation and secured in place by metal wire netting to hold the insulation in place in the event of a fire. APRIL 2016 Page 2 of 6 GFS-600 (Formerly A-40) DEFLECTOR POSITION CPVC PIPE INSTALLATION • 1 '/to 4 inches below the upper deck for wood truss and Horizontal runs of CPVC piping must be located with the I bar joist constructions. bottom of the piping not more than 6" (152.4mm) above the • 1 1/2 to 4 inches below the joists for non-combustible ceiling below or above ceiling insulation (if present), or one insulation filled solid and composite wood joist third depth of the combustible concealed space as mea- constructions. sured between the top surface of the ceiling below to the • 4 '/inches away from trusses. bottom of the floor above or the bottom of the noncombus- tible insulation above. Whichever is smaller. CONCEALED SPACE SIZE When the lower joists are greater than 6"(152.4mm) in All spaces must have a minimum open space (from top of height, CPVC piping is permitted to be attached directly to lower joist, cord, or truss to bottom of upper joist, cord, or the topof theIjoist. ThetCPVC piping can be used to supply truss)of 6" (152.4mm). (see Figures 1 and 2) the Globe he Upright Sprinklers as well as the sprinklers protecting the space below. Unobstructed wood truss and bar joist construction must not When using 1" (DN25) or larger pipe, a hanger must be have a total bottom of floor to top of ceiling space height of located at the truss nearest a sprig for purposes of re- more than 60" (1.5m). (see Figure 2) straint. If using 3/," (DN19) piping, all sprigs over 12" Joist construction with noncombustible insulation in the (304.8mm) must be laterally braced using methods upper deck must not have an open space (from top of lower described in the NFPA standards. Where CPVC piping must joist to bottom of upper joist) of greater than 60 inches in be offset to go over an obstruction that will violate the hori- size. They must not have a total concealed space height of zontal positioning requirements the CPVC piping must be greater than 72" (1.8m). This allows for a maximum lower spaced not greater than 6 inches from that obstruction and joist space of 12" (304.8mm). an additional Globe IC Upright Sprinkler must be provided Solid wood joist and obstructed truss construction must to protect the section of CPVC piping (see Figure 1 and 2). not have an open space (from top of lower joist or truss to CPVC piping must be kept a minimum of 18"(457.2mm)lat- bottom of upper joist or truss) of greater than 60"(1.5m) in erally away from heat sources such as heat pumps,fan mo- size. They must not have a total concealed space height of tors, and heat lamps. greater than 84"(2.1m). The upper joist space must not be greater than 12"(304.8mm) in depth (see Figure 2) I@"(114mm)MIN. 1 1n'(30mm)MIN. TO FACE OF WOOD TRUSS 6'(152mm)MAX. P(1)38m)MIN.7 OR TOP CHORD OF BAR JOIST FOR CPVC PIPE UPPER DECK %/////II///////////I///WAWA////////////////'I.%/////// TOP CHORD , 4'(100mm)MAX. FRAME ARMS MUST BE \ ill b .. INSTALLED IN-LINE .. " WITH PIPE RUN • .'(125mm)MAX. a (MODEL IC SPRINKLER) -rMMI=ate FOR CPVC PIPE 12'(305m30 MIN. P ! ! 1.1. . I,' 6'1152mm)MIN. 00'(1524mm)MAX. I"I"t"I'•'I"I' '�f OBSTRUCTION I-IIII�-Illi._-Ill. ;1 I. 1 1 �- CEILING\-BOTTOMP OF OF PIPE/ D WHEN OFFSETTING CPVC PIPE OVER AN '(152mm)MAX.ABOVE CEILING TO BOTTOM OF PIPE OBSTRUCTION A GL5608 MODEL'IC-SPRINKLER OR NON COMBUSTIBLE CEILING INSULATION.OR 1/3 OVER BE INSTALLED DIRECTLY ON THE CPVC OBSTRUCTION. C THE DEPTH OF CONCEALED SPACE(AS MEASURED OVER THE OBSTRUCTION. FROM TOP SURFACE OF CEILING TO BOTTOM SURFACE OF DECK),OR WHICH EVER IS SMALLER. FIGURE 1 : CPVC PIPE UNOBSTRUCTED WOOD TRUSS AND BAR JOIST CONSTRUCTION APRIL 2016 Page 3 of 6 GFS-600 (Formerly A-40) INSULATION MUST BE HELD NONCOMBUSTIBLE SOLID WOOD JOIST IN PLACE WITH METAL. INSULATION • POSITE WOOD JOIST 12'(305mm)MAX.DEPTH WIRE NETTING 12'(305mm)MAX.DEPTH r�rt4irl\ r at!Tri\\U\�\a\� rr \'\\I" UPPER DECK ulY�'uu /�uuuluu/Ou 13uuuulC,Lu. ,,1W111I11QIN1tItItIVAWNI1,ttt111T11tItYNltltlltltl l�ltltltlt�ltltltrtltl,��,•Itlt 1'(I(38mm)MIN. 1t1��1/1tltltl/It//1t/t1/11� /////t/t1/lt/t/t///t�i111t/t{//tIt//11/t1///Y/t/tltlt/t/t/t1/7t/t/tltll�l/it/11 4'0°2mm)MAX.1.H� ✓//It/1tHIryr,P Itrmm ,••IIIII,,,, •1,1 1 . L5fi0: •"(152mm)MAX. T (MODEL IC SPRINKLER) FOR CPVC FRAME ARMS MUST '(152mm)MAX. BE INSTALLED _1k FOR CPVC IN-LINE WITH PIPE RUN U 6'(152mm)MIN. ••�•••t••�•••I•'f ' OBSTRUCTION 72' 60'(1524mm)MAX. (1829mm) ..1..1..1..1..1.. ' MAX. .1..1..1..1..1.. FILING BOTTOM OF PIPE-• 5 TOP F CHORD w��wvvvvvvvvvvvvvvwvvvvvvvvvvvvvvvvvvvv�smvvvvvvcavvvvvvvvvvvvvvvvc� WHEN OFFSETTING CPVC PIPE OVER AN OBSTRUCTION A GL560B MODEL'IC'SPRINKLER MUST BE INSTALLED DIRECTLY ON THE PIPE OVER THE OBSTRUCTION. 6'(152mm)MAX.ABOVE CEILING OR NON-COMBUSTIBLE CEILING INSULATION.OR 10 THE DEPTH OF CONCEALS AREA(AS MEASURED FROM TOP SURFACE OF CEILING TO TOP SURFACE OF JOIST INSULATION ABOVE),OR WHICH EVER IS SMALLER.WHEN THE LOWER JOIST IS GREATER THAN 6'(152mm)IN HEIGHT CPVC PIPING IS PERMITTED TO BE ATTACHED DIRECTLY TO THE TOP OF THE JOIST. FIGURE 2: CPVC PIPE NON-COMBUSTIBLE INSULATION FILLED UPPER DECK SOLID WOOD OR COMPOSITE WOOD JOIST CONSTRUCTION STEEL PIPING DESIGN REQUIREMENTS SYSTEM TYPE DRAFT CURTAINS Wet pipe system and dry type systems. Unobstructed wood truss construction and noncombustible bar joist construction must be 8" (203.2mm) in height or ALLOWABLE CONSTRUCTION one third of the depth of the concealed space, whichever is greater. Draft curtains must be constructed of a material TYPES that will not allow for heat to escape through or above them. • Unobstructed wood truss construction' Obstructed wood truss and solid wood joist construction • Unobstructed bar joist construction' must be 6" (152.4mm) in height or one third of the depth of • Solid wood joist construction2 the concealed space, whichever is greater. Draft curtains • Obstructed wood truss construction2 must be constructed of a material that will not allow for heat to escape through or above them. • Non-combustible insulation filled solid wood joist constructions DEFLECTOR POSITION • Non-combustible insulation filled composite wood joist • 1 'A to 4 inches below the upper deck for unobstructed construction wood truss and bar joist constructions NOTE: • 1 1/2 to 4 inches below the joists for noncombustible Upper joist/truss cannot be more than 4"(101.6mm)in height. insulation filled solid and composite wood joist 2 Upper joist/truss cannot be more than 12"(304.8mm)in height. 3 The joist space in non-combustible insulation tilled joist construction must be construction. completely filled with noncombustible insulation and secured in place by metal • 1 %to 2 inches below the joist or truss for solid wood wire netting to hold the insulation in place in the event of a fire, joist or obstructed truss construction. PARTITION REQUIREMENTS • 4 'A2 inches away from trusses For unobstructed wood truss construction, unobstructed BLOCKING bar joist construction, solid wood joist construction, and For solid wood joist and obstructed wood truss construction obstructed wood truss construction the concealed space blocking must be provided in each of the channels between being protected must be broken up into areas no greater the upper joists or trusses. The blocking must be located than 1000 square feet either by full height walls or by draft where the draft curtains intersect the channels. The block- curtains. ing must be installed to the full depth of the joists and be Noncombustible filled joist construction is not required to be installed as to not allow heat to escape through or above the broken up into partitioned areas. blocking. The blocking must be installed using either the same material as the joists or a noncombustible material. APRIL 2016 Page 4 of 6 GFS-600 (Formerly A-40) CONCEALED SPACE SIZE All spaces must have a minimum open space (from top of size. They must not have a total concealed space height of lower joist, cord, or truss to bottom of upper joist, cord, or greater than 72"(1.8m). This allows for a maximum lower truss)of 6"(152.4mm)(see Figures 3, 4, and 5). • joist space of 12"(304.8mm) (see Figure 4). Unobstructed wood truss and bar joist construction must not Solid wood joist and obstructed truss construction must have a total concealed space height of more than 60"(1.5m). not have an open space (from top of lower joist or truss to (see Figure 3). bottom of upper joist or truss) of greater than 60"(1.5m) in Joist construction with noncombustible insulation in the size. They must not have a total concealed space height of upper deck must not have an open space (from top of lower greater than 84"(2.1 m). The upper joist space must not be joist to bottom of upper joist) of greater than 60"(1.5m) in greater than 12"(304.8mm)in depth(see Figure 4). 4 1/2"(114mm)MIN.T• UPPER DECK FACE OF WOOD TRUSS OR TOP CHORD OF BAR JOIST 1 1/2"(38mm)MIN. PI, Naito. TOP CHORD 4"(100mm)MAX. P GL5608 U m" (MODEL IC SPRINKLER) 'R; I 60" FRAME ARMS MALLEDUST M ��r� (1524mm) BE INST IN-LINE WITH PIPE RUN (152mm) MAX. 6" MIN. �u�lr /�/-% FILINGimmemonnommomi $ FIGURE 3: STEEL PIPE UNOBSTRUCTED WOOD TRUSS OR NON-COMBUSTIBLE BAR JOIST CONSTRUCTION 2OLIDOR UPPER DECK SOLID WOOD JOISTS/OBSTRUCTEDCENTER TRUSS 16"(406mm)ON CEN II�6�ggql 1 12"�3A5 mm) 6 i1 1"( 1mm MAX. 2"(51 mm)MAX. GL5608 FRAME ARMS MUST (MODEL IC SPRINKLER) 84" BE INSTALLED " ' (2134mm) IN-LINE WITH PIPE RUN = Y- MAX. I I CEILING 60"(1524mm)MAX. I �• J FRAMING CEILING FIGURE 4: STEEL PIPE OBSTRUCTED WOOD TRUSS OR SOLID WOOD JOIST CONSTRUCTION APRIL 2016 Page 5 of 6 GFS-600 (Formerly A-40) • UPPER DECK NON-COMBUSTIBLE 2x FLOOR SOLID INSULATION COMPOSITE WOOD JOIST WOOD JOIST 10000.�000cA00000000aoo�w.aw000���.:aa0000���� YI%/Yit4YIVIViteillPdiYJiLStVI %VI '�L4'O�lilP:'�'�4�i'�4ti'di'ic'i IVI t/tlti%IIII/tit/YiVIt/tlt/t/t1/11tIt/�it/�ltit/tltitl/*W/tit11/t/t{titlt/t/AYN/t/tll/tViYOYi 1 1i2"(38mm)MIN. PM lltilltIt/t1�It/tlt/tlt.-t/t11/�1�1/t/tlt/t/ttootltitltltIyt/t/t/otlt/t/yt/t{ttlt/t/tllilt/tit, A"(102mm)MAX. �tftt.Etryttt 4ttttteetttttl P1tttttm. 2/Att ,trot/y,, r INSULATION MUST BE HELD L5608 I 1 IN PLACE WITH METAL R (MODEL IC SPRINKLER) WIRE NETTING ow UP I 6'(152mm)MIN. - -ed- 60"(1524mm)MAX. FRAME ARMS MUST BE INSTALLED ' ' 72" IN-LINE WITH PIPE RUN (1826mm) . FILING FRAMING MAX CEILING FIGURE 5: STEEL PIPE NON-COMBUSTIBLE INSULATION FILLED UPPER DECK SOLID WOOD OR COMPOSITE WOOD JOIST CONSTRUCTION ORDERING INFORMATION GLOBE® PRODUCT Quantity* Model Number • Style • Orifice *Thread Size WARRANTY Temperature • Finishes • Desired Quantity Globe agrees to repair or replace any of its own manu- factured products found to be defective in material or work- Wrenchmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 Airpark Dr. Technical Support Standish, MI 48658 1-800-248-0278 www.globesprinkler.com r,�! Ph. 989-846-4583 techservice@globesprinkler.com ,1„ APRIL 2016 Page 6 of 6 GFS-600 (Formerly A-40) • @WICK ESPONSE= EXTENDED COVERAGE kikr LIGHT HAZARD AUTOMATIC SPRINKLERS FIRE SPRINKLER CORPORATION MODEL GL5614 PENDENT• RECESSED PENDENT DESCRIPTION AND OPERATION The Globe Quick Response Model GL5614 Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a ` low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. ,45 While this Quick Response Sprinkler provides an aesthetically M pleasing appearance, it can be installed wherever standard light hazard extended coverage pendent sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accor QUICK RESPONSE dance with their listings and in accordance with NFPA 13. EXTENDED COVERAGE The heart of Globe's GL Series sprinkler proven actuating PENDENT assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the inter- nal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern. -4111111011111111011 TECHNICAL DATA .See reverse side for Approvals and Specifications. •Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200° (93°C) •Water Working Pressure Rating - 175 psi (12 Bars) ,. •Factory tested hydrostatically to 500 psi (34 Bars) .Maximum low temperature glass bulb rating is -67°F (-55°C) •Frame - bronze •Deflector- brass •Screw- brass QUICK RESPONSE •Bulb seat- copper •Spring - nickel alloy •Seal - teflon EXTENDED COVERAGE •Bulb - glass with alcohol based solution, 3mm size RECESSED PENDENT •Escutcheon Assembly-steel •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A.MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY ORANGE/RED INTERMEDIATE YELLOW/GREEN JANUARY 2014 A-42 BULLETIN GL5614,REV. EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS MODEL GL5614 PENDENT • RECESSED PENDENT SPECIFICATIONS NOMINAL THREAD SIZE LENGTH FINISHES "K"FACTOR FACTORY BRONZE 5.6 (80 metric) 1/2"NPT (15mm) 2 1/2" (6.4cm) CHROME s WHITE POLYESTER BLACK POLYESTER" NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED AS CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS SIN STYLE MODEL FACTOR HAZARD' 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) cULus PENDENT GL5614 5.6 LH X X X X X RECESSED PENDENT 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. cULus LISTING DESIGN - USE REQUIREMENTS FOR LIGHT HAZARDS ONLY SIN MODEL STYLE TEMP. AREA OF MIN.PRESSURE FLOW IN COVERAGE P.S.I. G.P.M. 135°F/57°C 16'x 16' 21.5 26 155°F/68°C GL5614 PENDENT 175°F/79°C 18'x 18' 34.7 33 RECESSED PENDENT 200°F/93°C 135°F/57°C 20'x 20' 51 40 CROSS SECTION 2 15/16"DIA. 2"MIN.DIA. HOLE IN CEILING 129/32" 1 L _I 1"x 1/2" j f REDUCER Ji1�7 118"MMS.. Ir j1075. CEILING cup -� 1/8" RETAINER I"MIN. I 3/4"MAx. ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured •Quantity•Model Number•Style •Orifice products found to be defective in material or workmanship for a +Thread Size •Temperature•Finishes desired period of one year from date of shipment. *Quantity-Wrenches- P/N 325390 For specific details of our warranty please refer to Price List •Quantity- Recessed Wrenches- P/N 325391 Terms and Conditions of Sale(Our Price List). •Quantity- Protective Caps- P/N 327109-CAP(Friction Fit Recessed) 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 -Air 11- 959-846-4583 FAX 989-846-9231 1-800-248-0278 www.g)obesprinkler.com FIRE SPRINKLER CORPORATION JANUARY 2014 PRINTED U.S.A. BULLETIN GL5614,REV.# • LUCK "ESPONSE AUTOMATIC SPRINKLERS TRM GL SERIES .�{ �_ k if 110Si i £ UPRIGHT® PENDENT KLE . CI(` Ps VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray , 4, sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT a NVENTIONAL direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that 4,4 contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal =-' pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. QUICK RESPI SE TECHNICAL DATA PENDENT JERTICAL *See reverse side for Approvals and Specifications. SIDEWALL *Temperature Ratings - 135°F (57°C), 155°F (68°C), .� 175°F (79°C), 200°F (93°C), 286°F (141°C) *Water Working Pressure Rating - 175 psi (12 Bars) •Factory tested hydrostatically to 500 psi (34 Bars) *Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE HORIZONTAL LPC C ;, _ - ! *Frame bronze * Deflector- brass * Screwbrass •Lodgement Wire - stainless steel a SIDEWALL HORIZONT •Bulb seat - copper • Spring - nickel alloy a Seal - teflon SIDEWALL •Bulb - glass with alcohol based solution, 3mm size *SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F 551`- C/68°C ,'' ORANGE/RED - °F 00 s _=i IN ICKr7I UIH a IC r7 tzvu r; 74`C..1 3 C r ELwvvivREmiv HIGH °F 141°C = BLUE 225°F' ,,I 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 * FAX 989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 UICK ESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT 0 PENDENT 8 VERTICAL SIDEWALL HORIZONTAL SIDEWALL 0 CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH, FINISHES 2.0 (33 ,..mot, L.) 1/2" t rT 2 1/4" (.5.7...,.) 1.2 (.i3 „...LI.,) 1/2" 14rT 2 1/1" (:..7.,,„) Factory Bronze Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 7.0 (111 t,.0l,l..) 1/2" NrT 2 1/4" (5.7..,..) Black Polyester 2.3 8.1 (11C me,io) 3/1" NrT 2 7/10" ((I£ „.) METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZARD' 135°F 155°F 175°F 200°F 286°F cULus FM LPC CE NYC-DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — X G14215 4 7 1 H X X X X X X — — — X UPRIGHT IGL5615 5.6 LH/OH X X X X X X X X X X I GL8115 7.8* LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7,8° LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826§ 2.8 LH X X X X X X — — — X ' HORIZONTAL 14226 8, 4 2 I H , X X X X X X X SIDEWALL L5626§ 5.6 LH/OH X X X X_ X X X — -- X GL56276 5.6 LH/OH X X X X X — — X X -- j GL8127§ 8.1 LH/OH X X X X X X — — — — CONVENTIONAL GL5624. 5.6 LH/OH X X X X X — — 1 X X — (OLD STYLE) GL8125 8.1 LH/OH X X X X X — — I X X -- 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6"BELOW THE CEILING. INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6'MIN.SPACING. "I-UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD "1/2"NPT ORDERING INFORMATION GLOBE®PRODUCT WARRANTY SPECIFY •Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured •Orifice • Thread Sizes • Temperature products found to be defective in material or workmanship for a •Finishes desired period of one year from date of shipment. •Quantity-Wrenches- P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). � n Anti �� 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 ,3 ; so 989-846-4583 FAX 989-846-9231 )F SA t LE RPORA IC# 1-800-248-0278 www.globesprinkler.com JUNE2012 PRINTED U.S.A. BULLETIN GL5615,REV.#9 • 161 AUTOMATIC SPRINKLERS vor GL SERIES DRY TYPE SPRINKCORPOLER HORIZONTAL SIDEWALL FIREDESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive SURFACE MOUNT element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the fh additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approv- ing authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly SLEEVE & SKIRT is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. j TECHNICAL DATA • See reverie side for Approvals and Specifications. RECESSED • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C) 200°F (93°C), 286°F (141°C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) , �� _ • Maximum low temperature glass bulb rating is -67°F (-55°C) $� • Frame - bronze • Deflector- brass • Screw- brass • Bulb Seat - brass • Spring - nickel alloy • Seal -teflon • Retainer- brass • Pin - stainless steel • Torsion Spring - stainless steel • Orifice Insert- brass EXTENDED • Bulb- glass with alcohol based solution, 3mm size • 3/4"NPT or 1"NPT• Outer Tube-galvanized steel pipe • Inner Tube - stainless steel •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A.MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY �� „. �� �r€ � �+ arse ORANGE/RED INTERMEDIATE a 'S YELLOW/GREEN a > K HIGH BLUE APR 2017 GFS-520a(Formerly A-58) LUCK ESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE HORIZONTAL SIDEWALL SPECIFICATIONS SIN MODEL NOMINAL THREAD LENGTH FINISHES "K"FACTOR SIZE GL5641 1 5.6(80 metric) 1"NPT Factory Bronze GL5642 5.6(80 metric) 3/4"NPT cULus Variable to 48" Chrome FM Variable to 36" White Polyester2 GL8141 8.0(115 metric) 1"NPT Black Polyester'•' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS DEFLECTOR MIN. SIN 135°F 155°F 175°F 200°F 286°FDISTANCE STYLE MODEL HAZARD' (57°C) (68°C) . (79°C) (93°C) (141°C) *FM cULus TODI TANCE BETWEEN Inches(mm) SPRINKLERS 11 Feet(Meters) Horizontal GL5641 LH X X X X X X X Sidewall 4(102) Recessed GL5642 LH X X X X X -- X to 6(1.8) Horizontal 12(305) Sidewall GL8141 LH/OH X X X X X -- X SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. 'HORIZONTAL SIDEWALL STYLE-FM APPROVED 155°F(68°C),200°F(93°C) AND 286°F(141°C) 'RECESSED HORIZONTAL SIDEWALL STYLE-FM APPROVED 155°F(68°C)AND 200°F(93°C) LH:LIGHT HAZARD; OH:ORDINARY HAZARD TEE FIITMG CROSS SECTIONS IMPORTANT INSTALLATION DATA MEI B1fiJ°'S 15500. Globe GL Series Dry Pendent Sprinklers should be �AN9 IBA wssyss TEEIPTING " GP.M". ANSI MA / ,r , installed in accordance with the requirements set la•r ALL �MS'T16A CLAM Iss �'""G ( forth in NFPA 13. These sprinklers are to be installed 1 4•ro lr i CDUNG° Z - — nslvG^om NE--- s , Ts using a pipe wrench applied to the outer tube. When 31rri 2"°IA MIN. GA I� E°" , 1 "GEINWA1 this is not possible, the proper sprinkler head wrench s__ may be used with extreme care for lengths up to • r WOFIEGE a' approximately 18". Excessive force may distort the FACE OF F I:H MIN. FACE OF FACE OF ,_,ACE OF frame thus destroying the unit. FITTING MOUNTING "i FITTING A" •A. �/ SURFACE "'i 3/4'NPi -�MWNT[NG 1•MIN.WRIT- l+ 33/4"MIN. I 23/4•MIN.1°"PT $UPrACE When installed in a wet system extending into a 3/4"MIN.1"NVI 4 JO'MAX.-, EXTENDED RECESSED freezing area see chart on Dry Caution Sheet for ffNG EF ➢NG minimum exposed barrel length to prevent ice EIONG T ,8630." 3oa plugs. Please refer to our Dry Caution Sheet for further PNA G163 LIAR 155 00. I AN5] U 3)/3•GIA UU T r -- T CLASS i PNSI1fiA CUSS III lu J E NG 7 important installation data. r ro lr 4 - ESCIRCHECN �4 'HG']UN WALL 13• u11R"OIA MIN •� rl it '' ° '" "" ORDERING INFORMATION • M FGN / /' SPECIFY MOUNTING •Quantity•Model Number•Style•Orifice FAQ FACE OF F0T°F M RFACE TEE— l SURFACMOUE Fi NGNG - SURFACE FIRING •>• •Temperature• Finishes desired -31/T MIN.3•NVf-'.I 3I/2"'N•••'"•"°`'-31/'•"'" ""'M1M I'"°' •Quantity-Wrenches-P/N 333010 l l/1•MIN.I"NPT AI MAX. SLEEVE&SKIRT SURFACE MOUNT •Quantity Recessed Wrenches-PIN 337014 GLOBE®PRODUCT WARRANTY •Quantity-Protective Caps-P/N 327109-cap(Friction Fit Recessed) • Globe agrees to repair or replace any of its own manufactured Escutcheons Desired products found to be defective in material or workmanship for a "A"Dimension-Distance from face of fitting to the finished period of one year from date of shipment. ceiling line regardless of escutcheon used. For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). ,_ 4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 FAX 989-846-9231 FIRE 5PRIM( EF1CO8PORATION 1-800-248-0278 www.globesprinkler.com APR 2017 PRINTED U.S.A. GFS-520a(Formerly A-58) tLJCD Fire & Building Products Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Series EC-5 — 5.6 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers /± not representative of all possible cor- General rosive atmospheres. Consequently, it is recommended that the end user be Description consulted with respect to the suitability of these corrosion resistant coatings The Series EC-5 Extended Coverage for any given corrosive environment. Pendent Sprinklers are decorative The effects of ambient temperature, glass bulb sprinklers designed for use concentration of chemicals, and ( ° in light hazard occupancies.They are gas/chemical velocity, should be con- intended for use in automatic sprinkler sidered, as a minimum, along with the systems designed in accordance with corrosive nature of the chemical to standard installation rules (e.g., NFPA which the sprinklers will be exposed. 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the WARNINGS maximum coverage area of 225 ft2 The Series EC-5 Extended Coverage (20,6 m2)for standard coverage sprin- Sprinklers described herein must be klers used in light hazard occupancies. installed and maintained in compli- The recessed version of the EC-5, in- ance with this document, as well as tended for use in areas with a finished with the applicable standards of the ceiling, uses the two-piece Style 50 National Fire Protection Association, Recessed Escutcheon. The Style 50 in addition to the standards of any AlitV Recessed Escutcheon provides up to other authorities having jurisdiction. 3/8 inch (9,5 mm) of total adjustment Failure to do so may impair the per- from the flush pendent position. The formance of these devices. adjustment provided by the Recessed The owner is responsible for maintain- Escutcheon reduces the accuracy to ing their fire protection system and de- which the fixed pipe drops to the sprin- vices in proper operating condition. k ; -, klers must be cut. The installing contractor or sprinkler Corrosion resistant coatings, where manufacturer should be contacted applicable, are utilized to extend the with any questions. life of copper alloy sprinklers beyond that which would otherwise be ob- Model/Sprinkler tained when exposed to corrosive at- mospheres. Although corrosion resis- Identification Technical tant coated sprinklers have passed the standard corrosion tests of the appli- Number Data cable approval agencies, the testing is TY3232- Pendent,5.6K Approvals UL and C-UL Listed. FM and NYC Ap- TY3232 is a redesignation for C3232. proved. (Refer to Table A for complete IMPORTANT approval information including corro- Always refer to Technical Data sion resistant status. The approvals Sheet TFP700 for the "INSTALLER apply to the service conditions indi- WARNING" that provides cautions cated in the Design Criteria section.) with respect to handling and instal- lation of sprinkler systems and corn- Maximum Working Pressure ponents. Improper handling and in- stallation can permanently damage Pipe Thread Connection a sprinkler system or its compo- 1/2 inch NPT nents and cause the sprinkler to fail Discharge Coefficients to operate in a fire situation or cause 1/2 it to operate prematurely. K=5.6 GPM/ps2 (80,6 LPM/bar ) Pagel of 6 JANUARY, 2005 TFP228 . .... .__ -_ Page 2 of 6 TFP228 Components: 1/2"** ESCUTCHEON PLATE 1 • Frame 1 NPT SEATING SURFACE 3- Button - I 3- Seaaling Assembly — 1f/ 4- Bulbp 2 % NV = 2-1/16" 5- Compression ifili Screw 3 ���; >_ (_) I (52,4 mm) 6 Deflector* J \ 7/1m 111 NO mm) 1-5/16" * Temperature rating is 4 I ' NOMINALMAKE-IN (33,3 mm) indicated on Deflector. t�5 ;=s`* Pipe thread � connections per ISO 7/1 can be provided 6* on special request. FIGURE 1 SERIES EC-5(TY3232)EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINISH(See Note 4) HAZARD TYPE TEMP. BULB NATURAL CHROME WHITE* LIQUID BRASS PLATED POLYESTER LIGHT PENDENT 135F/57°C Orange 1,2,5 Refer to Table B for UL and C-UL 155°F/68°C Red 1,2,3,5 Sensitivity Rating and REC.PENDENT 135°F/57°C Orange 1,2,5 Refer to Table C for FM w/Style 50 Esc. Sensitivity Rating 155°F/68°C Red 1,2,3,5 NOTES: 1 Listed by Underwriters Laboratories, Inc.(UL). 2 Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL). 3.Approved by Factory Mutual Research Corporatipn(FM). 4.Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. 5.Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only.Listings and approvals apply to color(Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Temperature Ratings installation, as applicable (Ref. Table 135°F/57°C and 155°F/68°C Operation A, B, and C)., Finish The glass bulb contains a fluid that UL and C-UL Listing Sprinkler: Refer to Table A expands when exposed to heat.When Requirements Recessed Escutcheon:White Coated, the rated temperature is reached, the . Chrome Plated, and Brass Plated fluid expands sufficiently to shatter the 1. The Series EC-5 Sprinklers may be glass bulb, allowing the sprinkler to used for the coverage areas shown Physical Characteristics activate and flow water. in Table ID,based on maintaining the Frame Bronze minimum specified flow rate as a Button Bronze function of coverage area and haz- Sealing Assembly Design and group for all of the sprinklers in Beryllium Nickel IN/Teflon-1- - the design area. Bulb Glass (3 mm dia.) Criteria Compression Screw 2. With respect to heat sensitivity, the Bronze The Series EC-5 Extended Coverage Series EC-5 Sprinklers are permit- Deflector Brass Pendent Sprinklers must only be in- ted to be used with unobstructed stalled in accordance with the applica- construction consisting of flat, (Registered trademark of DuPont ble UL and C-UL Listing or FM Ap- smooth ceilings with a pitch of one in proval requirements as indicated six as defined and permitted by below.Only the Style 50 Recessed Es- NFPA 13. cutcheon is to be used for recessed 3. The minimum allowable spacing be- TFP228 Page 3 of 6 Installation 135°F 155°F The Series EC-5 Sprinklers must be installed in accordance with the follow- AREA STYLE ing instructions: NOTES 16 x 16 Pendent OR OR Do not install any bulb type sprinkler if 16 x 16 Style 50 Recessed QR CR the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler 18 x 18 Pendent QR QR held horizontally, a small air bubble 18 x 18 Style 50 Recessed OR QR should be present. The diameter of the air bubble is approximately 1/16 inch 20 x 20 Pendent OR N/A (1,6 mm). 20 x 20 Style 50 Recessed QR N/A A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 QR:Quick Response to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- N/A:Not Applicable mum of 21 ft.lbs. (28,5 Nm) of torque is to be used to install sprinklers. TABLE B Higher levels of torque may distort the SENSITIVITY RATING FOR UL AND C-UL LISTING sprinkler inlet with consequent leak- OF SERIES EC-5 SPRINKLERS age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under-or over-tightening the Sprinkler. Readjust the position of the 135°F 155°F sprinkler fitting to suit. Step 1.The sprinkler must be installed AREA STYLE with the deflector parallel to the mount- ing surface. Pendent sprinklers must 16 x 16 Pendent OR OR be installed in the pendent position. 16 x 16 Style 50 Recessed QR QR Step 2. After installing the Style 50 mounting plate (or other escutcheon, 18 x 18 Pendent QR QR as applicable) over the sprinkler pipe 18 x 18 Style 50 Recessed OR OR threads and with pipe thread sealant applied to the pipe threads, hand 20 x 20 Pendent QR QR tighten the sprinkler into the sprinkler 20 x 20 Style 50 Recessed QR QR fitting. Step 3.Wrench tighten pendent sprin- QR:Quick Response klers using only the W-Type 6 (End A) Sprinkler Wrench.Wrench tighten the recessed pendent sprinklers using only the W-Type 7 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref.Figure 3 and 4) is to be applied to the sprinkler wrench flats (Ref.Figure 1). TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-5 SPRINKLERS tween the Series EC-5 Sprinklers, FM Approval to prevent cold soldering, is 8 feet Requirements (2,4 m). The Series EC-5 Extended Coverage Sprinklers are to be installed in ac- 4. The Series EC-5 Sprinklers are to be cordance with the applicable Factory installed in accordance with all other Mutual Loss Prevention Data Sheet. requirements of NFPA 13 for ex- Information provided in the FM Loss tended coverage pendent sprin- Prevention Data Sheets relate to, but klers. are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to-ceiling distance. Page 4 of 6 TFP228 DESCRIPTION AREA GPM PSI I TY3232(K=5.6)PENDENT 16 x 16 26 21.6 18 x 18 33 34.7 / WRENCH RECESS 20 x 20 40 51.0 (END"A"USED 1 ft.=0.3048 m FOR TY3232) 1 ft2=0.093 m2 1 gpm=3.785 Ipm 1 psi=0.06895 bar 1 gpm/ft2=40.74 mm/min FIGURE 4 TABLED W-TYPE 6 SPRINKLER FLOW CRITERIA FOR UL AND C-UL LISTING WRENCH OF SERIES EC-5 SPRINKLERS WRENCH RECESS 2-7/8"DIA. 9/16±1/8" (73,0 mm) 7/16"(11,1 mm) (14,2a3,2 mm) 2-1/4"DIA. 3/16"(4,8 mm) '�n FACE OF (57,2 mm) 11 / SPRINKLER 3/32" FITTING (2,4 mm) (� / \Jr PUSH WRENCH IN TO ENSURE ENGAGEMENT MOUNTING MOUNTING WITH SPRINKLER SURFACE PLATE WRENCHING AREA CLOSURE FIGURE 5 1-1/8"(28,6 mm) W-TYPE 7 RECESSED 7/8"(22,2 mm) SPRINKLER WRENCH FIGURE 2 SERIES EC-5 RECESSED PENDENT SPRINKLER ASSEMBLY annual inspections per NFPA 25 WITH TWO-PIECE 3/8 INCH TOTAL ADJUSTMENT should suffice; however, instead of in- STYLE 50 RECESSED ESCUTCHEON specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better altered after leaving the factory. Modi- determine the exact sprinkler condi- Care and fled sprinklers must be replaced. tion and the long term integrity of the Sprinklers that have been exposed to corrosion resistant coating as it may Maintenance corrosive products of combustion, but be affected by the corrosive conditions have not operated,should be replaced present. The Series EC-5 Sprinklers must be if they cannot be completely cleaned maintained and serviced in accord- by wiping the sprinkler with a cloth or The owner is responsible for the fin- ance with the following instructions: by brushing it with a soft bristle brush. spection, testing, and maintenance of Care must be exercised to avoid dam- their fire protection system and de- NOTE vices in compliance with this docu- Before closing a fire protection system age to the sprinklers - before, during, ment, as well as with the applicable and after installation. Sprinklers dam- main control valve for maintenance standards of the National Fire Protec- work on the fire protection system that aged by dropping, striking, wrench tion Association (e.g., NFPA 25), in it controls,permission to shut down the twist/slippage, or the like, must be re- addition to the standards of any other affected fire protection systems must placed.Also,replace any sprinkler that authorities having jurisdiction.The in- be obtained from the proper authori- has a cracked bulb or that has lost stalling contractor or sprinkler manu- ties and all personnel who may be liquid from its bulb. (Ref. Installation facturer should be contacted relative affected by this action must be notified. Section). to any questions. Sprinklers that are found to be leaking Frequent visual inspections are rec- It is recommended that automatic or exhibiting visible signs of corrosion ommended to be initially performed for sprinkler systems be inspected, must be replaced. corrosion resistant coated sprinklers, tested, and maintained by a qualified after the installation has been corn- Inspection Service in accordance with Automatic sprinklers must never be pleted,to verify the integrity of the cor- local requirements and/or national painted, plated, coated, or otherwise rosion resistant coating. Thereafter, codes. TFP228 Page 5 of 6 Limited Ordering Warranty Procedure Products manufactured by Tyco Fire When placing an order,indicate the full Products are warranted solely to the product name. Please specify the original Buyer for ten (10) years Sprinkler Identification Number(SIN), against defects in material and work- quantity,and temperature rating.Refer manship when paid for and properly to the Price List for complete listing of installed and maintained under normal Part Numbers. use and service.This warranty will ex- Contact your local distributor for avail- pire ten (10) years from date of ship- ability. ment by Tyco Fire Products. No war- ranty is given for products or Sprinkler Assemblies with NPT components manufactured by compa- Thread Connections: vies not affiliated by ownership with Specify:TY3232,(specify temperature Tyco Fire Products or for products and rating), Extended Coverage Pendent components which have been subject Sprinkler with (specify finish), P/N to misuse,improper installation,corro- (specify). sion,or which have not been installed, maintained,modified or repaired in ac- 135'F/57c cordance with applicable Standards of Natural Brass PSN 51-051-1-135 chrome Plated PSN 51-051-9-135 the National Fire Protection Associa- White Coaled PSN 51-051-4-135 tion,and/or the standards of any other White(RAL9010)* PSN 51-051-3-135 Authorities Having Jurisdiction. Mate- 155°F/6a°C rials found by Tyco Fire Products to be Natural Brass PSN 51-051-1-155 defective shall be either repaired or Chrome Plated PSN 51-051-9-155 replaced, at Tyco Fire Products' sole White Coated PSN 51-051-4-155 option.Tyco Fire Products neither as- White(RAL9010)* PSN 51-051-3-155 sumes, nor authorizes any person to *Eastern Hemisphere sales only. assume for it, any other obligation in connection with the sale of products or Recessed Escutcheon: parts of products. Tyco Fire Products Specify: Style 50 Recessed Escutch- shall not be responsible for sprinkler eon with(specify finish), P/N(specify). system design errors or inaccurate or incomplete information supplied by Style 50 Recessed Escutcheon Chrome Plated PSN 56-711-9-010 Buyer or Buyer's representatives. White Color Coated PSN 56-711-4-010 IN NO EVENT SHALL TYCO FIRE White(RAL9010)* PSN 56-7113.010 PRODUCTS BE LIABLE, IN CON- Brass Plated PSN 56-711-2-010 TRACT,TORT,STRICT LIABILITY OR *Eastern Hemisphere sales only. UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, Sprinkler Wrench: SPECIAL OR CONSEQUENTIAL Specify: W-Type 6 Sprinkler Wrench, DAMAGES, INCLUDING BUT NOT P/N 56-000-6-387 LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO Specify:W-Type 7 Recessed Sprinkler FIRE PRODUCTS WAS INFORMED Wrench, P/N 56-850-4-001 ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED.INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Page 6 of 6 TFP226 TYCO FIRE PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446