Loading...
Plans Y PROJECT INFORMATION SOLAR ARRAY PROPOSED BOB & DEBBIE YANOFSKY ARRAY# MODS TILT AZIMUTH MAX. HEIGHT OWNER 16675 SW BIRDSONG ST, BEAVERTON OR 97229 ARRAY#1 25 24° 90° 0'-7" Elemental Project#20-1154 ,;;" ' RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION SCOPE OF HYUNDAI HiD-S29ORG(BK) SOLAR MODULES Approved plans WORK (25)X290W=7.250 KWdc @ STC shall on jpl s (25) M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS BUILDING RESIDENTIAL DRAWINGS INDEX _ CODES AND 2017 OREGON ELECTRICAL SPECIALTY CODE,2019 OREGON G-1 COVER SHEET STANDARDS STRUCTURAL SPECIALTY CODE - PV-1 SITE PLAN HYUNDAI HiD-S29ORG(BK) PV-2 ROOF LAYOUT MODULE (L)65.94"X (W) 39.41"X(H) 1.3" PV-2.1 STRUCTURAL DETAILS SPECS WEIGHT= 39.7 LBS OFFICE COPY COMBINED WEIGHT OF MODULES AND RACKING:3.20 PSF<_4.5 PSF PV-3 ELECTRICAL PLAN ELEMENTAL ENERGY PV-4 SINGLE LINE DIAGRAM 1339 SE 8TH AVE SUITE B EQUIPMENT PORTLAND, OR 97214 PV-5 LABELS CONTRACTOR LICENSE#: 195141 CONTACT:TOM CROWE SUPPORTING DATA SHEETS, PHONE: 503-967-5786 DOCUMENTS STRUCTURAL CALCULATIONS COMPOSITION ROLL ROOF, 2X4 TRUSSES @ 24"O.C., DF#2 ROOF SLOPE(S): 24° AREA OF ROOF(PLAN VIEW)= 1,881 SF LIABILITY AREA OF NEW ARRAY=412 SF=22%OF ROOF AREA(ARRAY< 25% OF ROOF AREA) The City of Tigard and its CLIMATE DATA SOURCE: PORTLAND INTERNATIONAL AP, OR, USA, employees shall not be 45.59N, 122.60W SITE DETAILS ASHRAE EXTREME LOW:-6.4°C responsible for discrepancies ASHRAE2%HIGH:35°C which may appear herein. ASHRAE EXTREME HIGH:41.9°C WIND SPEED: 110 MPH RISK CATEGORY: II VALIDITY OF PERMIT I WIND EXPOSURE CATEGORY: B GROUND SNOW LOAD:20 PSF THE ISSUANCE OF A PERMIT CITY OF TIGARD BASED ON CONSTRUCTION REVIEWED FOR,,CODD COMPLIANCE DOCUMENTS AND OTHER DATA SHALL NOT PREVENT Approved: [ ] THE CODE OFFICIAL FROM OTC: [ ] REQUIRING THE CORRECTION OF ERRORS. ORSC 105.4 Permit #: r&S2,O D — DOO`SCP Address: Us1/75 c 6 f-A Y ) Suite #: 13): f7/eI_ Date: ✓/ Zb OFFICE COPY / CONTRACTOR BOB & DEBBIE YANOFSKY COVER SHEET ELEMENTAL ENERGY ee ELEMENTAL 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION System AC Size @ STC: 5.375 kW System DC Size @ STC:7.250 kW Page: PORTLAND,OR 97214 ENERG 1 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S290RG(BK) SOLAR MODULES Ph: 503-967-5786 Elemental Project#20 1154 (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS G_1 Drawn:TC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 3/4/2020 SOLAR ARRAY PROPOSED (N) M215-60-2LL-S25-IG INVERTER ARRAY# MODS TILT AZIMUTH MAX. HEIGHT (INSTALLED UNDER MODULE) ARRAY#1 25 24° 90° 0'-7" I / 24° ❑ 24° I < > I / ❑ / / ❑ / -- (N)ARRAY#1 / I / I AC DISCONNECT (EXTERIOR WALL) I •• I /71E (E) METER(EXTERIOR WALL) (E) PANEL (INTERIOR WALL) I < > (E) PROPERTY LINE* I I � — — - - - - - - - J N W E (E) RESIDENCE (FRONT OF HOUSE) S SITE PLAN NOTE: *CHECK WITH CITY/COUNTY OR LAND SURVEYOR "' FOR ACCURATE PROPERTY LOCATE. SW BIRDSONG ST SCALE:3/32"= CONTRACTOR BOB & DEBBIE YANOFSKY SITE PLAN ELEMENTAL ENERGY ELEMENTAL System AC Size @ STC: 5.375 kW System DC Size @STC:7.250 kW Page: 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION PORTLAND, OR 97214 ENERGY 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S290RG(BK) SOLAR MODULES Ph: 503-967-5786 " Elemental Project#20 1154 (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS PV-1 Drawn:TC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 3/4.12020 , ROOF PROPERTIES MODULE MENCHANICAL COMPOSITION PROPERTIES 41'-2„ ROOF MATERIAL ROLL HYUNDAI MODEL HiD-S29ORG(BK) ROOF SLOPE 24° (L)65.94"X(W) i DIMENSIONS 39.41"X (H) 1.3" MEAN ROOF HEIGHT -38 FT WEIGHT 39.7 LBI \ DECK SHEATING is'OR THICKER OSB 5 OR PLYWOOD CONSTRUCTION 2X4 TRUSSES 24° NOTES: 0 EZR MOUNT, TYP. OF 62 42 O 2X4 TRUSSES @ 24" O.C.. TYP. I 0 IRONRIDGE XR100 RAIL n 4 RIDGE (PROVIDE 12" SETBACK) t V O O5 EAVE Li I i 1 � u 1 1 1 iiiil I aiaN timli I - I - 1 .;. __1(I (Di i y / GENERAL NOTES: IIIIIIIIIIIIIIII ame 1. RAFTER LOCATIONS ARE — -- — APPROXIMATE. ACTUAL „4_ - - -- -- 3 -N ----- N I LOCATIONS MAY DIFFER p AND CONTRACTOR MAY NEED TO ADJUST MOUNT IM — — — — — LOCATIONS. IN NO CASE - a I e -a e- SHALL THE MOUNT SPACING a L I EXCEED MAX. MOUNT v I I SPACING. 24° I �� �F .,, owl 111 NI „ obi a�i o ! Iv -) I I I \ CO Z 0- 5 1 28' m Alk ROOF LAYOUT PV-2.1 SCALE: 3/16"= 1'-0" CONTRACTOR BOB & DEBBIE YANOFSKY ROOF LAYOUT ELEMENTAL ENERGY ELEMENTAL 1339 SE 8TH AVE SUITE B D RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION System AC Size @ STC: 5.375 kW System DC Size @ STC:7.250 kW Page: PORTLAND, OR 97214 EN ER VEI lGY 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S29ORG(BK) SOLAR MODULES Ph: 503-967-5786 Elemental Project#20-1154 (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS PV-2 Drawn:TC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 314/2020 HYUNDAI B NOTES: HiD-S29ORG(BK) MODULE PV 2 1 GENERAL NOTES: O EZR MOUNT, TYP. OF 62 1. RAFTER LOCATIONS ARE 0 2X4 TRUSSES @ 24" O.C.. TYP. APPROXIMATE. ACTUAL �� 2 LOCATIONS MAY DIFFER 0 IRONRIDGE XR100 RAIL O' AND CONTRACTOR MAY \� NEED TO ADJUST MOUNT ® RIDGE (PROVIDE 12" SETBACK) LOCATIONS. IN NO CASE \��� SHALL THE MOUNT SPACING O EAVE ° �.\ EXCEED MAX. MOUNT 0 JOIST N SPACING. u 5 i / / i / / r PV MODULE bo co 0 _\ .,� �/ I I I I [ I I I I I I i I I t l 1 I I I I I I t \ , .. b I I I I I I I I I I I I co I 1 I I t I I I t t I t I )) /// 5/16"x4.5" LAG — SCREW WITH 2.5" MIN. MPOSITION LEMBEDMENT ROLL J — ' MOUNTING DETAIL sue:NTS 1 , • 41) SECTION DETAIL smie 3/16"= 1'-0" CONTRACTOR BOB & DEBBIE YANOFSKY STRUCTURAL DETAILS ELEMENTAL ENERGY E39 ELEMENTAL System AC Size @ STC: 5.375 kW System DC Size @ STC:7.250 kW Page: 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION PORTLAND, OR 97214 ENERGY 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HID-S29ORG(BK) SOLAR MODULES Ph: 503-967-5786 Elemental Project#20 1154 (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS PV-2.1 Drawn:TC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 3i412020 KEYED NOTES: GENERAL NOTES: 1. CONDUIT AND WIRING IS O ((EXTERIORDISCONNECT N) AC DIAGRAMMATIC. FINAL ROUTING TO BE DETERMINED BY INSTALLER. O (N) M215-60-2LL-S25-IG INVERTER BRANCH #2 (14 MODS) (ARE LOCATED UNDERSIDE OF EACH MODULE AND ARE INSTALLED TO CONTINUOUS SUPPORT RAIL) \ (N) BREAKERED SOLADECK s1 (ON ROOF,WEIGHT: 16.5 LB) e 1 U (N) PV MODULE ®_. ... __--ill_.----- - -�- - -._.._-___�. O (EXTERIOR WALL) n 24° J-BOX U (E) SERVICE PANEL (INTERIOR WALL) ®-- ---a f --a- -■----- I 4 l • I \ \ BRANCH# 1 (11 MODS) — \ 1 1 1 24° \ 1 1 3/4" EMT OR ROMEX IN ATTIC \ w (FIELD VERIFY FINAL ROUTING) Z ,1_ rn . (6) ---(- n' ELECTRICAL PLAN SCALE: 1/4"= 1'-0" CONTRACTOR BOB & DEBBIE YANOFSKY ELECTRICAL PLAN ELEMENTAL ENERGY *I': . ELEMENTALPage: 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION System AC Size @STC: 5.375 kW System DC Size @STC:7.250 kW 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S29ORG(BK) SOLAR MODULES PORTLAND, OR 97214 ENF Y (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS PV-3 Ph: 503-967-5786 Elemental Project#20-1154 Drawn:IC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 3/412020 VOLTAGE DROP CALCULATIONS MODULE SPECS INVERTER SPECS WIRE RUN #OF MODS V(VOLTS) I(AMPS) L(FT) VD" VD(%) WIRE SIZE RACEWAY MODULE MAKE HYUNDAI ENPHASE MODEL M215-60-2LL-S25-IG BRANCH#1 TO J-BOX 11 240V 9.85A 47 0.84V 0.35% 12 AWG FREE AIR MAX.POWER Pmax 215 W BRANCH#2 TO SOLADECK 14 240V 12.54A 60 1.33V 0.55% 12 AWG FREE AIR MODULE MODEL HID-S290RG(BK MAX.INPUT VOLTAGE 48 V J-BOX TO SOLADECK 11 240V 9.85A 7 0.27V 0.11% 12 AWG 3/4"EMT MAX.POWER Pmax 290 W HiD-S29ORG(BK)Voc @-6.4°C 43.2 V SOLADECK TO AC DISCONNECT 25 240V 22.5A 45 2.51 V 1.05% 10 AWG 3/4"EMT OPEN CIRCUIT VOLTAGE Voc 39.6 V 43.2V<48V YES AC DISCONNECT TO POI 25 240V 22.5A 10 0.56V 0.23% 10 AWG 3/4"EMT MAX.POWER POINT Vmp 31.9 A OUTPUT CURRENT 0.9 A MAX VOLTAGE DROP:1.83% SHORT CIRCUIT CURRENT Isc 9.75 A OUTPUT VOLTAGE 240 V, 14) MAX.POWER POINT Imp 9.2 A DC/AC RATIO 1.35 Voc TEMP.COEFF. -0.29%/°C Pmax TEMP.COEFF. -0.40%/°C OMETER JUNCTION BOX(TYP.) A 3/4'EMT: MODULE J-BOX (E)SERVICE CONDUCTORS (2)#12 AWG THWN-2 CONDUCTORS q•. ENPHASE ENVOY IQ (1)#12 AWG THWN-2 GROUND ENPHASE M215.60-2LLS25-IG EXISTING 120V INTEGRATED GROUNDING CLAMP,TYP LAY INRACKI LUG,TYP.NGR AIL,TYP. O OUTLET f � ''"� (� °' PATCH CABLE TO "`rr l NETWORK ROUTER \\.. — • • • BRANCH CIRCUIT#1 _ (11)HYUNDAI . LOCKABLE,NON-FUSED HiDS290RG(BK) MODULES —t1 AC DISCONNECT � (11)MICRO-INVERTERS 030A,240V.2POLE ,ice ---t1. (EXTERIOR WAIL) J F9 Fi G i 240V VAC 30A 2 — — BRANCH TERMINATOR Q-TERM-10(TYP.) - NE #S BARE CU(TYP.) L NEUTRAL I 1—I GROUND 1 I BRANCH CIRCUIT#2 GROUND 000 T�f" • • • _ ` (14)HYUNDAI HID-S290RG(BK)MODULES EXISTING � _ (14)MICRO-INVERTERS SERVICE PANEL IRREVERSIBLE SPLICE Q 240V VAC 120240V,10,3W 225A WITH 200A MAIN BREAKER (E)GEC _T S Fi ali (E)GROUNDING — ELECTRODE 30A BREAKERED SOLADECK, NEMA-3R 120240V.1$ 3(4'EMT OR EQUIVALENT: (2)#10 AWG THWN-2 CONDUCTORS (1)#10 AWG THWN-2 NEUTRAL ENPHASE Q CABLE(TYPJ (1)#10 AWG TH WN-2 GROUND BLACK-L1 RED-L2 GENERAL NOTES: WHITE•NEUTRAL GREEN-GROUND 1. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE,IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS. 3. SEE PV-5 FOR LABELING REQUIREMENTS. 0 4. WHEN METALLIC CONDUIT IS USED,INSTALLER SHALL PROVIDE GROUND BUSHINGS AS REQUIRED BY CODE OR A PLASTIC BUSHING SHOULD BE INSTALLED. CONTRACTOR BOB & DEBBIE YANOFSKY SINGLE LINE DIAGRAM ELEMENTAL ENERGY ELEMENTAL Systemv 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION AC Size @STC: 5.375 kW System DC Size @ STC:7.250 kW Page: PORTLAND, OR 97214 ENERGY 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S29ORG(BK) SOLAR MODULES Ph: 503-967-5786 Elemental Project#20 1154 (25)M215-60-2LL-S25-IG ENPHASE MICRO INVERTERS PV-4 Drawn: Contractor# 195141Date: Checked:DA Rev:PERMIT SET 3i4%202020 3• TWO POWER SOURCES PRESENT. SECOND SOURCE IS A PV ARRAY.AC PHOTOVOLTAIC SYSTEM DISCONNECT A WARNING AI 0 DISCONNECT LOCATED IN THIS PANEL. • O OPERATING AMPS 22.5A RAPID SHUTDOWN INITIATION DEVICE OPERATING VOLTAGE 240V 0 LOCATED OUTSIDE NEXT TO METER 1I ELECTRIC SHOCK HAZARD LOCATION:RSID DO NOT TOUCH TERMINALS LOCATION: INTERCONNECTION PANEL QUANT[TY:1 TERMINALS ON BOTH LINE AND r. 4 LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION O PV SOLAR BREAKER WARNING: DUAL POWER SOURCES PRESENT. DO NOT RELOCATE 7540 WATT PHOTOVOLTAIC ARRAY LOCATED ON ROOF. THIS OVERCURRENT O AC DISCONNECT LOACTES INSIDE GARAGE ELECTRICAL LOCATION:RSID DEVICE PANEL. RAPID SHUTDOWN INITIATION DEVICE LOCATED LOCATION:NEXT TO OUTSIDE NEXT TO THIS METER. SOLAR BREAKER LOCATION: AT METER QUANTITY: 1 INSIDE PANEL NEC 2017 690.12,690.56(C)(1)(a) SOLAR PV SYSTEM EQUIPPED ® WARNING ® 0RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 0WITH RAPID SHUTDOWN O DUAL POWER SUPPLY LOCATION:RSID SOURCES:UTILITY GRID AND TURN RAPID SHUTDOWN SOLAR PHOTOVOLTAIC SYSTEM SWITCH TO THE"OFF" SOLAR ELECTRIC POSITION TO SHUT , PV PANELS ` LOCATION: MAIN SERVICE PANEL DOWN PV SYSTEM AND REDUCE SHOCK HAZARD I IN THE ARRAY NOMINAL OPERATING AC VOLTAGE: 240V LABEL FOR PV SYSTEMS THAT SHUT DOWN THE NOMINAL OPERATING AC FREQUENCY: 60HZ ARRAY AND THE CONDUCTORS LEAVING THE ARRAY. O MAXIMUM AC POWER: 5.375KW MAXIMUM AC CURRENT: 22.SA THE LABEL SHALL UTILIZE CAPITALIZED CHARACTERS MAXIMUM OVERCURRENT PROTECTIVE WITH A MINIMUM HEIGHT OF 3/8"IN BLACK ON YELLOW BACKGROUND,AND THE REMAINING DEVICE FOR AC MODULE PROTECTION: 30A CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16"IN BLACK ON WHITE LOCATION AT POINT OF INTERCONNECTION CODE SECTION:NEC 690.52 BACKGROUND. LOCATION: MAIN SERVICE DISCONNECT CONTRACTOR r- BOB & DEBBIE YANOFSKY LABELS ELEMENTAL ENERGY ELEMENTAL 1339 SE 8TH AVE SUITE B RESIDENTIAL GRID INTERACTIVE SOLAR ELECTRIC INSTALLATION System AC Size @ STC: 5.375 kW System DC Size @ STC:7.250 kW Page: PORTLAND, OR 97214 EN n I V ERGY 16675 SW BIRDSONG ST, BEAVERTON OR 97229 (25)HYUNDAI HiD-S29ORG(BK) SOLAR MODULES Ph: 503-967-5786 Elemental Project#20 1154 (25)M215-60-2LL-S25•IG ENPHASE MICRO INVERTERS PV-5 Drawn:TC Date: Contractor# 195141 Checked:DA Rev:PERMIT SET 3/4/2020