Loading...
Report ` l 2tfD-CDCO`t2, tO RECEIVED 22oSw4�� � a'p_ JUN 16 2020 OFFICE COPY 5eSimplEx TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Liste ' L �i•iIGN SmartSync Operation AudibleNisible Notification MEA (NYC) Acceptance with Horn and Synchronized Flash, Non-Addressable Features es.m le ... - o• Audible/visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements(refer - —,—.- to important installation information on page 3) p. p • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens aM Operates over a two-wire SmartSync circuit to FIRE FIRE provide: • Horns that are controlled separately from strobes on the FIRE same two-wire circuit 1111111111111111, • "On-until-silenced"and"on-until-reset"operation on the same two-wire pair f`,,r • SmartSync horn activation of Temporal pattern,March FIRE "�� Time pattern(at 60 BPM),or on continuously0 _ • Strobe appliances on the same circuit operating at a _ IS���1 synchronized 1 Hz flash rate — f( ii/,/ • Class B operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM)4905-9938 Wall and Ceiling Mount Ards • Class A operation when connected to the 4905-9938 Descri 4 tion SCM or with 4100U series fire alarm control panel NACs Multi-Candela TrueAlert ANs with horn and Wall mount ANs features: synchronized strobe provide convenient installation to standard electrical boxes.The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection.Since each model can be inspection,and testing selected for strobe intensity output,on-site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA(stairwells,small rooms,highly reverberant areas,etc.) Wall mount AN housings are a one-piece assembly (including lens)that mounts to a single or double gang,or Optional adapters and wire guards: 4"square standard electrical box.The cover can be • Wall mount AN adapters are available to cover surface quickly removed(a tool is required)and covers are mounted electrical boxes and to adapt to Simplex® available separately for color conversion. 2975-9145 boxes Ceiling mount Ards install using standard 4"electrical • UL listed red wire guards are available for wall or boxes.Color choice is determined by model number. ceiling mount A/Vs Visible notification appliance(strobe): Strobe Intensity Selection • 24 VDC xenon strobe;intensity is selectable as 15,30, During installation,a selection plug at the back of the 75,or 110 candela with visible selection jumper secured housing determines the desired strobe intensity.An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing Audible notification appliance(horn): 7125-0026:317 for allowable values and%or conditions concerning material presented in this • Low current,24 VDC electronic horn with harmonically document.Accepted for use—City of New York Department of Buildings—MEA35-93E. y Refer to page 2 for listing status of wire guards.Additional listings may be applicable; rich sound output suitable for either steady or coded contact your local Simplex product supplier for the latest status.Listings and approvals operation(Temporal or 60 BPM March Time pattern) under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. • UL listed to Standard 464 S4906-0002-6 11/2014 Strobe Application Selection SmartSync Two-Wire Control Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code:BOCA, while the strobe remains flashing.The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, reflections can be seen from one location,synchronized and 4100U Fire Alarm Control Panels(refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi-Candela ANs Model Mounting Housing Color "FIRE"Lettering Description 4906-9127 Wall Red White 4906-9129 White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 15,30,75,or 110 candela;operates with SmartSync two-wire 4906-9128 Red White control 4906-9130 Ceiling White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"Wx 1-5/8"D 4905-9940 White surface mounted boxes (136 mm x 133 x"( mm) 4- depth with strobe=4-318111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1l8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Optional Sound Damper;package of 20;field installed adhesive backed 4905-9838 horn output attenuator;reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm) NOTE:After Sound Damper installation,measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16" H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6- x 7" mm (216 mm x 156 mm x 6 mm) 4905-9928' Ceiling Red Adapter Plate,required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension,use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0002-6 11/2014 AN Specifications Wall Mount or Ceiling Mount,Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC;see Note 1 below 6' ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C);10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep,modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 d8A 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"Wx 2-5/8"D(121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Mounting Mounting is compatible with single gang,double gang,and 4"(102 mm)square boxes, 11lipall IMPORTANT! WALL MOUNT 1-1/2"(38 mm)deep,by others pp�� pp�� INSTALLATION HEIGHT REFERENCE Optional 4905-9838 '-o-' IU7 r --- ) 1 Sound Da field attached %g I • Bottom of lens to attenuate sound 5 to 6 dBA is either even i�=, I with,or slightly Electrical o ' _ ! O above bottom box outline Wiring access hole > �' t. I r of compatible Nr 0 1 -Am boxes # Wiring terminals for m_I�p l l) SmartSync operation W" emeA. Mounting Holes: r li 4"square(4) NFPA 72 requires 80"(2.03 m) °""°°�` ® I1 Single gang(2) that the entire lens minimum ail t, be not less than �I v I'fr Double gang(3) 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection "0 , +I plug,accessible only from rear of housing; . F [I N E factory setting is 15 cd dill Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-6 11/2014 Ceiling Mount A/V and Guard Installation Reference Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box 1Four mounting clamps included,two each side ® a. imm R C Ceiling reference, 1. flush mounted box, ' II --- "' ) Optional 4905-9915/-9916 Adapter, ? '''''. recommended for surface mounted box - — - Wiring terminals are Optional 4905-9927 rlocated behind the housing Red Wire Guard , 0--- ' F 0 h " End View�, -- Strobe intensity viewing slot / _ Intensity selection plug, — accessible only from rear of lens housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt AMIEW and Optional Wire Guard EINEn Surface mount conduit and O M box shown for reference ——, 4"(102 mm)square I�It7 ������ I,FI' I lill�l�l�l.alrid t •'--'-• box profile,1-1/2" II�II�I-I=I I1II I II (38 mm)deep i■EIS L i I%4I�_�__=�1i_�1r1 O O I Optional III 4905-9961 1_....::.i © ,• I Wire Guard wLlr- o IR y 1 �I_�� t 49D5-9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). ®Si m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0002-6 11/2014 www.simplex-fire.com ©2014 Tyco Fire Protection Products.All rights reserved.All spechcations and other information shown were current as of document revision date and are subject to change without notice.