Loading...
Report (3) , rid 31/2020 GREENHECK J b: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG Model: G-103-VG -024.40 Direct Drive Centrifugal Roof Exhaust Fan 23.70 1.75 35.70 Dimensional ' ime Quantity 1 } (12.00) Weight w/o Acc's(Ib) 35 Weight w/Acc's(Ib) 62 Optional Damper(in.) 12 x 12 Roof Opening(in.) 14.5 x 14.5 19.00 SQ OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 1.0 / 0.25 Requested Volume(CFM) 1,060 Actual Volume(CFM) 1,060 1409 FRPM . Total External SP On.wg) 0.25 0.8 _ / 0.20 — Fan RPM 1409 — Operating Power(hp) 0.15 a Elevation(ft) 108 0.6 m -- — 0.15 ' Airstream Temp.(F) 70 a Air Density(lb/ft3) 0.075 N �� : o • Tip Speed(ft/min) 4,104 F(2) 0.4 . — -- 0.10 - Static Eff.(%) 28 aV ...c — m `m 0.2 0� - -- - 0.05 c cc system Motor 0.0 ' - 0.00 Motor Mounted Yes 0 2 4 6 8 10 12 14 Size(hp) 1/4 Volume (CFM)x 100 Voltage/Cycle/Phase 115/60/1 Enclosure ODP x Operating Bhp point 0 Operating point at Total External SP Motor RPM 1725 Fan curve Efficiency Rating High System curve Brake horsepower curve Windings 1 FLA(Amps) 2.85 - Notes: All dimensions shown are in units of in. 'NEC FLA-based on tables 430248 or 430.250 of c mcQ DINID - Sound Power by Octave Band National Eleoldcal Cade 2014.Actual motor FLA may vary, amino)E for sizing(henna!overload,consult factory. Rpn11W Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones LwA-A weighted sound power level,based on ANSI S1.4 Data 8 Data -A weighted saund pressure level,based on 11.5 dB D sound attenuation per Octave band at 5 -dBA levels are not Inlet 70 75 72 66 60 59 52 45 69 57 8.5 licensed by AMCA Intemational imase•�kR --_- Sones-calculated using ANSUAMCA 301 al ft Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:1ChrisHessick\Tigard Animal Hospital.gfcj Page 2 of 15 GREENHECK Printed Date: 03/31/2020 Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG Model: G-103-VG Direct Drive Centrifugal Roof Exhaust Fan • Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: Motor-Vari-Green EC motor Control-Dial for balancing UL/cUL 705 Listed-"Power Ventilators' Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Damper Shipped Loose,VCD-23-PB-12X12,Not Coated Damper Actuator(TF8120), 115 VAC Actuated Birdscreen:Galvanized,nom.84%Free Area Unit Warranty: 1 Yr(Standard) Selected Sub Marks See individual submittals for full details GPI-19-G12 Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 3 of 15 GREENHECK Printed Date: 03/31/2020 Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests.The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic )), 0 4.35 O 1.06 • 1.65 O 1 % • 0.72 12.00 1.06 — 2.50 �- Notes:All dimensions shown are in units of in. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:1ChrisHessick\Tigard Animal Hospital.gicl Page 4 of 15 rinted Date: 31/2020 111GREENHECK Job: Tigard Animal Hospital Building Value In Air. Mark: REF Model: G-103-VG Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING 12.00 14.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE 024.40 - 23.70 Th1.75 35.70 (12.00) � 19.00SQ— DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.glcj Page 5 of 15 121 GREENHECK Printed Date: 03/31/2020 Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Vari-Green motors feature a soft-start and inherent thermal and current protection built into each unit. Inrush current at start up is eliminated and the motor will automatically reduce speed or turn off if overloaded or it becomes too hot. Motor Configuration SLACK > INPUT VOLTAGE WHITE Input Voltage: 115 7 - GREEN GROUND Speed Reference: Dial on Motor Permanent Dial: Yes SPEEDO Control Configuration coNrRL Control Type: N/A -- + Transformer: None VAFU-GREEN. Motor DRAWINGO .1 v2 Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 6 of 15 31/2020 fGREENHECK J b: Tigard Animal Hospital Building Value in Air. Mark: R E F Model: G-103-VG Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications- Galvanized - 16 ga channel frame- Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.- Synthetic axle bearings -Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Belimo Jackshaft Quantity: 0 Model: TFB120 Mounting: Internal Quantity: 1 12 ; � ; �, max.. ... 10.0 - �� 5. 12 Min. 1.3 max. DAMPER TYP. SECTION VIEW • Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in. undersize Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 7 of 15 Printed Date: 03/31/2020 LGREENHECK Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG G-103-VG Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SF'(in.wg) RPM Power(hp) (CFM) (CFM) 1,060 1,060 0.25 1409 0.15 1 .4 0.35 1725 FRPM 1.2 z 0.30 1 .0 I 0.25 1409 FRPM F' CL • c 0.8 - - - _ -1 0.20 0.6 , ' 0.15 a. 2 Q U) fzi 0.4 ,.o 0.10 m 0.2 0.05 300 F- PM 0.0 . -.._.._. -I._ - 1 I I I 0.00 0 3 6 9 12 15 Volume (CFM) x 100 L, Operating Bhp point O Operating point at Total External SP Fan curve - - - -System curve Brake horsepower curve Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 8 of 15 • •GREENHECK 03/31/2020 J b: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103--VG Warranty 1 Yr (Standard) WARRANTY AND LIABILITY: SELLER warrants to Buyer that products manufactured are free from defects in material and workmanship for a period of 1 Yr(Standard)from the date of shipment. SELLER'S obligations and liabilities under this warranty are limited to furnishing FOB factory or warehouse at SELLER's designated shipping point, freight allowed to Buyer's city, (or point of export for shipments outside the conterminous United States) replacement equipment(or at the option of SELLER parts therefore)for all Seller's products not conforming to this warranty and which have been returned to the manufacturer. No liability whatever shall attach to SELLER until said products have been paid for and such liability shall be strictly limited to the purchase price of the equipment shown to be defective. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by SELLER prove defective during this period,they should be returned to the nearest authorized motor service station. SELLER will not be responsible for any removal or installation costs. Electrical components, excluding motors, are warranted only to the extent warranted by the original manufacturer. To the extent that SELLER is entitled to pass through a warranty of the original equipment manufacturer of the electrical goods sold, SELLER will pass through such warranties to Buyer. The legal remedies described in this Warranty are the sole exclusive remedy of Buyer. SELLER MAKES NO OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, REGARDING ITS PRODUCTS, OR ITS SELECTION AND APPLICATION, INCLUDING, BUT NOT LIMITED TO, COMPLIANCE WITH BUILDING CODES, SAFETY CODES, LAWS, MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE. This warranty is extended solely to the Buyer. It is nontransferable and non-assignable, and the Buyer shall not permit or authorize its employees, agents, representatives or customers to claim, represent or imply that this limited warranty extends or is available to anyone other than the Buyer. ANY MISUSE, NEGLECT, FAILURE TO FOLLOW INSTRUCTIONS OR MANUALS OF INSTALLATION OF MAINTENANCE REPAIR, SERVICE, RELOCATION OR ALTERATION TO OR OF, OR OTHER TAMPERING WITH, THE PRODUCTS PERFORMED BY ANY PERSON OR ENTITY OTHER THAN SELLER WITHOUT SELLER'S PRIOR WRITTEN APPROVAL - OR ANY USE OF REPLACEMENT PARTS NOT SUPPLIED BY SELLER, SHALL IMMEDIATELY VOID AND CANCEL ALL -WARRANTIES WITH RESPECT TO THE AFFECTED PRODUCTS. THE WARRANTY AND LIABILITY SET FORTH HEREIN -ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES WHETHER IN CONTRACT OR IN NEGLIGENCE, • EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE. SELLER PROVIDES NO INDEPENDENT WARRANTY FOR THIRD PARTY PRODUCTS OR COMPONENTS SOLD TOGETHER OR INCORPORATED WITH SELLER'S PRODUCT(S). THE SELLER HAS THE RIGHT TO SETTLE ANY AND ALL DISPUTES REGARDING THE WARRANTY. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 9 of 15 • Printed Date: 03/31/2020 LGREENHECK Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: G-103-VG AMCA amca IIIORLDWIDE CERTIFIED RATIAGS SOWID anc / PER(OR MICE AIR Qw MOV AT nnn COnTROL °oo nssOcmnon °•o, InTERnnrIOnnl. inc. AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per ANSI/AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 10 of 15 • Printed Date: 03/31/2020 ®GREENHECK Job: Tigard Animal Hospital Building Value in Air. Mark: REF Model: GPI-19-G12 17.50 17.50 Model: GPI 1 -'' Roof Curb 12.00 Standard Construction Features: -Roof Curb fits between the building roof and the fan mounted directly to the roof \ // support structure -Constructed of either 18 ga galvanized steel or 0.064 in. \,/ aluminum-Straight Sided without a cant-2 in.mounting flange-3 lb density %�i -,,'-x"> insulation-Height-Available from 12 in.to 42 in.as specified in 0.5 in. � increments. Notes: -The maximum roof opening dimension should not be � � greater than the"Actual"top outside dimension minus 2 in.. -The minimum roof -. -\--,, i" / ,! opening dimension should be at least 2.5 in.more than the damper dimension or `\�/' / recommended duct size.-The Roof Opening Dimension may or may not be the 21.50 21.50 same as the Structural Opening Dimension.-Damper Tray is optional and must \ /. be specified. Tray size is same as damper size.-Security bars are optional and \� must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. General Sizing Undersizing Weight Tag Qty Model Method (in.) (lb) 1 GPI-19 Nominal 1.5 16 Dimensions Nominal Nominal Actual Actual Actual Actual Hinge Hinge Curb Outside Outside Outside Outside Inside Inside Flange Flange Base Base Height Width Length Width Length Width Length Width Length Width' Length' (in.) (in.) (in.) (in.) (In.) (in.) (in.) (In.) (In.) (in.) (in.) 12 19 19 17.5 17.5 14 14 21.5 21.5 18 18 • *May not be applicable i Accessories Security 1 Insulation j Material Bars Liner (in.) Galvanized No No 1 Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:1ChrisHessick\Tigard Animal Hospital.gfcj Page 11 of 15 Printed Date: 03/31/2020 GREENHECK Job: Tigard Animal Hospital ® Building Value in Air. Mark: CEF Model: SP-A70 t14.625 -0-14.875-0-- Model: SP-A70 - - / Ceiling Exhaust Fan 5.5 = 1-- 13.25 Standard Construction Features: -Corrosion resistant galv steel scroll and housing-Sound absorbing insulation- t White designer non-yellowing grille-Round outlet duct collar with integral backdraft damper-Double inlet forward curved wheel-Plug type disconnect- Adj.mounting brackets-Field rotatable discharge-Energy Star Compliant Selected Options &Accessories: Motor rated for continuous use - 10.625 Motor with Thermal Overload h-13.25 06 3.938----1 -- Motor with CSA Approval Motor with 40 Degree C Ambient Temperature MOUNTING - 1 UL/cUL 507 Listed-Electric Fan BRACKET 9 6 Solid State Speed Control,6 Amp,Shipped Loose 11 Round Duct Connection 1. t [ILI Adjustable easy installation mounting bracket Energy Star Certified Designer Grille Polypropylene Wheel Material Can Be Used to Comply with:ASHRAE 62.2,California Title 24,and Washington State Energy Code Dimensional Quantity 1 Weight w/o Acc's(lb) 12 Weight w/Ace's(lb) 13 0.5 850 'rap ,' Performance M . Requested Volume(CFM) 6 60 0.4 `- - , Actual Volume(CFM) 57 Total External SP(in.wg) .0.226 a - ,; i . Fan RPM I 850 0.3 E m FLA(A) 0.27 I R 0.2 e Elevation(ft) 108 W - Airstream Temp.(F) 70 Air Density(Ib/ft3) 0.075 0 - Sones <0.3 '.4 - 0.1 — ---- c4 0.0 i- L..-1 -t-t I I II I I I I i ' I I I I I I I I 1 I I 0 10 20 30 40 50 60 70 80 90 Motor Volume(CFM) Motor Mounted Yes 0 Operating point at Total External SP **Input Watts(W) 14 Fan curve - - - - Voltage/Cycle/Phase 115/60/1 System curve Enclosure ODP Notes: All dimensions shown are in units of in. Qf11Cia •FLA is approximate and will vary slightly with the motor. OORLDWIDE/ Sones-calculated using AMCA 301 at 5 ft OEMnflnD Wattage is approximate and may vary between motors. Mannar amp Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:1ChrisHessick\Tigard Animal Hospital.gfcj Page 12 of 15 Printed Date: 030 31/20 �GREENHECK J b: Tigard Animal/Hospital Building Value in Air. Mark: CEF Model: SP-A70 Round Duct Connector Model: RDC Standard Construction Features: -Constructed of Polypropylene - Replaces the square discharge duct connector and damper using the existing mounting holes Sheet Metal Screw#10x3f8 b Screw hales 41141,14 'If Akt ". . — a .. - 111710.,1*. .:;‘•:•,, 40111101111111P-7.9. Alb, Notes:All dimensions shown are in units of in. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:1ChrisHessick\Tigard Animal Hospital.gfcj Page 13 of 15 Printed Date: 03/31/2020 j GREENHECK Job: Tigard Animal Hospital Building Value in Air. Mark: CEF Model: SP-A70 SP-A70 Min/Max Fan Curve Performance Requested Actual Total External Fan Operating Volume Volume SP(in.wg) RPM Power(hp) (CFM) (CFM) 60 57 0.226 850 0.01 0.5 850 FR 0.4 -4444, .. I • : : • Bhp @ aFcs M i kRpM 0.1 ,. 0.0 - - 0 10 20 30 40 50 60 70 80 90 Volume (CFM) 0 Operating point at Total External SP Fan curve - - -System curve Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.gfcj Page 14 of 15 GREENHECK Printed Date: 03/31/2020 Job: Tigard Animal Hospital ® Building Value in Air. Mark: CEF Model: SP-A70 AMCA amca WORLDWIDE • CERTIFIED RRTIRGS SOURD �Ana PERIORMA'CE AIR Qiete AIOVEIIIEAT 0 AID COITROl .Q'gp associITIOI 0 o4 IATERAITIOIRL IRC." AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW) does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication • 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM)shown is nominal. Performance is based on actual speed of test.The watt ratings shown are at free air.The sound ratings shown are for loudness values in spherical sones at 5 ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B:free inlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:chessick@johnsonair.com CAPS 4.31.1712 A:\ChrisHessick\Tigard Animal Hospital.glcj Page 15 of 15