Report (3)
Table Of Contents Project:—Untitled11 03/30/202C Prepared By: 1105A11/ rtu-1 3 Unit Report 4 Certified Drawing 5 Performance Summary 8 Unit Feature Sheet 11 Spec Sheet 12 Packaged Rooftop Builder 1.49y Page 2 of 12 rtu-1 Project:—Untitledll 03/30/2021 Prepared By: 11:05AM rtu-1 Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.49y Page 3 of 12 Unit Report For rtu-1 Project:-Untitledl 1 03/30/202C Prepared By: 11:05AN Unit Parameters Dimensions(fL in.)&Weight(lb.)*** Unit Model. 48FCEM07A2A5-0A0A0 Unit Length' 6'2.375" Unit Size- 07(6 Tons) Unit Width- 3'10.625" Volts-Phase-Hertz: 230-3-60 Unit Height: 3'5.375" Heating Type' Gas *** Total Operating Weight: 625 lb Duct Cfg• Vertical Supply I Vertical Return Medium Heat "' Weights and Dimensions are approximate. Weight Single Circuit,Two Stage Cooling(07 only) does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type: Throwaway Return Air Filter Quantity 4 Return Air Filter Size: 16 x 16 x 2 Unit Configuration Direct Drive-EcoBlue-Medium Static AI/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48FCEM07A2A5-OA0A0 Rooftop Unit 1 Base Unit Direct Drive-EcoBlue-Medium Static None Packaged Rooftop Builder 1 .49y Page 4 of 12 Certified Drawing for rtu-1 ' Project:—Untitledl 1 03/30/2020 Prepared By: 11:05AN ^vvIIvv Nil W<0E IR 11 n[PA0P6ttr N ETC 10twn.«M<AOU ETIMIUUf0Y Of 1XEIE MU"Dl OOCEMEYn NOTES: �wT �MM CUIITCOH S CE WILL MOT Of DIVLOSIO 01 MD Rf0 EN<ME11EYTE MAT PEAPIMCE D UNIT J X ACCEPTANCE(0 COATU[T. I. DIMENSIONS ARE IN INCHES DIMENSIONS 48FC404 33 3!8 18 5/8 O...n_y.RIIX01 MITlfll<wrzrz. IX 1 ]AflL IN N[LL IME Tf It3. 18171 [/12] 2. CENTER OF GRAVITY 48FC<.OS 13 3/8 VIP CONNECTION SIZES IBdi] [371] 33 3/8 11431718 4(HE 33-3/8 A 13I8'1351 DIA FIELD POWER SUPPLY MOLE d8FCu06 [6461 3.lip,DIRECTION OF A[A FLOW Ld41] [317] B 2' 1501 DIA POWER SUPPLY KNOCKOUT 41 3/8 18 SIB ,� t C 13/4. 151]DIA GAUGE ACCESS PLUG <BFCEE01 [1051] [d121 32-1/8 ' ECONOMIZER HOOD ' 4.-.E3- ALL VIEW DRAWN USING 3RD ANGLE [0111 IOPTIOOALI 16 D 118'1221 DIA FIELD CONTROL WIRING HOLE • 14011 E 3l4•-14 APT CONDENSATE DRAIN f—x5-5l6 F 1/2.-14 WET GAS CONNECTION 1662T airRETURN AIR 0 2 1/2' 1841 DIA POWER SUPPLE KNOCKOUT y .. .. . . '- V . . . . 1 ° ° ♦ THRU-THE-BASE CHART �/r-a�' C— THESE HOLES REQUIRED FOR USE 7�//�O� 10-1/8 RETURN LABTWR008A00, 009A00 ll�l�"!l// �xp*' (2111 AIR 1 81111�11�11��1 THREADED WIRE RLO'D HOLE NOP Illll0t`ll1\u\�� U4.' , .. .. CONDUIT 511E USE SIZES(MAX.) - 'Q��;�:0 /_ . L W IIY 11 SV 7/8' [22.2] ".. c / 3 1/2• 24V 7/8• (22.21 [1120. �y 29-1/2 I1120.91 E ALA. l718i E 3N' POWER 1.1/8'128.41 7 r INCONDENSATEPENING - 11-3/4 ZD (OOBA001 t/x'FPT GAS 1-1/8' [28.8] Z DRAIN OPENING (HIT] FOR'THRU-TNE-BASEPAN'FACTORY OPTION, 1 IN BASEPAN SUPPLY 16-5/8 177E NGS FOR ONLY Y, Y. 6 Z ARE PROVIDED AIR 16751 SUPPLY 71-712 I AIR , 1OO8A00/PROVIDES 31P FFPTITTING, TNRU CURS [3691 12-t12 D FLANGE S FITTI XG. I ❑'1/ 11-1/2 SEE TNRU THE- N r 1 l [2`] D BASE CHART `• 1 • • • 1 ID-1/8 �— 2N 23-3f4—�• 3-1I4�- �— 6-1// 12561 16031 1811 11581 [1111 HOOD I[307] I N I+—2Y 25 18.3/e [6351 [460] 2O 4-5/8 TOP 11181 E ITS. CONDENSATE 10-1/8 1 LECTRICAL DRAIN [2151 1251 DISCONNECT II III LOCATION 4 •- —______ 3LTER CONDEXS[A ,B,G OPT IOMAL CONTROL BOO 25-311 �I. COIL FACTORY ACCESS PANEL - ti-918 INSTALLED INDOOR BLOWER t6531 r DISCOXXEGi� ACCESS PANEL SUPPLE AIR_ LTUA y OFACTORY II { 7 AIA ``__' II FACTORY t II i INSTALLED `,II CONVENIENCE —� , I� ANDLE 11-1/B OUTLET 21-1l4 01E ,II 11�11[19i11 ,I' .0 I,_ I _/I5381 AIRSIDE 26n-- I II! i!!! ,8,' ��A1168] ,:. I off? -�—�ii.HAN 5-3/4 MM. 6-3/8 3-3// 46-5/8 8-3/8 11461 11411 I1771 ITUHI 1951 111881 30-1 l8 12141 26.11E 17661 16021 74-3/8 ^ 11 BAROMETRIC LEFT [18861 I1861 RELIEF FRONTSUPPLY 4 * FLOW AIR RETURN Reif AIR ITC CLASSIFICATION SHEET DATE SUPERCEPES 48FC 04-07 SINGLE PACKAGE ELECTRICAL I REV L 48TC003093 COOLING WITH GAS NEAT _ I U.S ECCN:XSR 7 OF 3 OB{07118 0812211E i , Packaged Rooftop Builder 1.49y Page 5 of 12 Certified Drawing for rtu-1 . Project:-Untitledl 1 03/30/2020 Prepared By: 11:05AIv Carrier liMm ea TnEE uu%gn a a mmMAMa Mma1 Wn mttM4 a11 1tt MAaM R SIO. UNIT CORNER CORNER CORNER COINER C.G. HEIGHT WvrTA.p HUNT w[mr"CM UNIT WEIGHT T WEIGHT(AI WEIGHT IB) WEIGHT CI WEIGHT IDl LBS. KG. LIES, KG. LBS. KG. LDS. KG, LBS. KG. R 1 Z 48FC4464 482 218 113 51 116 53 128 58 125 57 37 5/8 [9541 24 5/18 [824] 18 1/4[484] 456C4005 543 248 138 63 133 60 133 60 186 63 36 112 [9271 23 318 [584] 18 [4571 486C4406 558 252 142 84 136 62 136 62 142 64 36 1/2 [9221 23 3/8 [5941 18 [4571 48660007 661 275 162 73 152 69 141 61 151 60 36 19141 22 1/2 [5121 19 3/0[4021 *STANDARD UNIT WEIGHT IS NUN LOW GAS NEAT AND WITHOUT PACKAGING. f0R OTHER OPTIONS AND ACCESSORIES. REFER TO TOE PRODUCT DATA CATALOG. __ ___ _� ---- --------Al2 1/2 WITH C ECONOMIZER , BACK [3181 1 f - , 4 . CORNER A WITHOUT L ECONOMIZER HOOD CORNER B ECONOMIZER OPTIONAL DOOR \ � (OPTIONAL) SWING 0 /!/ 911111101111A ���G �\ \ -- RIGHT --- 1���I�0����111 ®0 i)N lii! AeW1BIIliN�1 • 10 CORNER D e CORNER C LEFT +—T X UJB TOP [18851 FRONT L . I NOTES: 11 . FOR ALL MINIMUM CLEARANCES LOCAL C00E5 OR JURISDICTIONS NAM PREVAIL. I Ip if Z CLE/RAPICE.. WITH B9fYCE WIiFt SERVER OPERATIND COIWCfiIE BARR SURFACE ER NONCCOCOCT1RE BARRER C cAOAATac �[�Z� �� _�. FRONT 48 [1219mm1 36 [914mm1 18 [457mm7 - - -- - LQT 48 [1219mm7 42 [1067mm1 -18 [457mm7 FRONT RAGE 48 (1219mm] 42 [1067mm1 18 [457mm] BACK W/ECOD 36 [914mm1 36 [914mm1 18 [457mm7 RCM 36 [914mm1 36 [914mm] 18 [457mm] TOP 72 [1829mm] 72 [1829mm1 72 [1829mm] ITS CLASSIFICATION SHEET DATE I SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL 48T0003093 REV U.S. ECCH:NSR 2 OF 3 09/07/18 1 06/22/18 COOLING WITH GAS NEAT i A Packaged Rooftop Builder 1.49y Page 6 of 12 Certified Drawing for rtu-1 • Project:—Untitled11 03/30/2020 Prepared By: 11:05AW l >i ss rzr �s n[v tz rr a If flgti. llig Iw111sra1 a rnsL L n""W bCI"n ruwm uo re Mt!1P wa nr ovvru comma s 9or mxtmm�rsn rnmwAl[[w rXAr 1M d7111 C Mt br B(MM.OM a u6v Atarg Gf glIci:T. •W... "•nritoV nmu carcAT. 71-1/8 1t805.31 (INSIDE THE BASE RAIL S SNIRTI e \ M ([r telun„<<�♦ �iii „... .....� l • �• , / 0 (INSIDE 110NB.SI IRE BASE RAILS) 1.] ' ;3- --3') •• •• •• is ysL3' /� '-'44.\4.:,.. 1..-,1, ir ‘11 `` \ i E3TT� [/B] �.__/ A 1ABIA f� I '01 INSIDE 9ASERAIL DIMENSIONS 4104 2%1-1IA 1 .\6 B - - 2Y 1-3/8 AN 1 3-1/4 In] 1253 1821 ..—2N 3/4 3-Ile -.-- (181 DETAIL C [991 TOP 4 PLCS FILTER ACCESS PANEL CORP. 1 CONDENSER It CONTROL BON INDOOR BLOWER (TOOL-LESS) ACCESS C01. ACCESS PANEL ACCESS PANEL . PANEL ^ • • C Ill I II ACCE53 PANEL 111 — 4---� ® IltSEE DETAIL C 10o 1 1 i� i ` 1 oO'1 1 1 ( I lis 1 T r 1 1 .1--r1 i, ) � - lQ J BACK 31/N __I L. 59-3/0 LEFT _-� 182.01 11509.01 2-3/8 7-1/8 (61.51 1180,71 TIP CURB 1 i WIDTH ITC CLASSIFICATION SHEET DATE 1 SUPERCEDES 48FC 04-07 SINGLE PACKAGE ELECTRICAL I REV U.S. ECCX:NBA 3 OF 3 09/01118 j 08/22/18 COOLING WITH GAS NEAT /OT0003093 A Packaged Rooftop Builder 1.49y Page 7 of 12 Performance Summary For rtu-1 Project:—Untitled11 03/30/2020 Prepared By: 11:05A l Part Number:48FCEMO7A2A5-0A0AO ARI EER. 11.00 IEER- 15.0 Base Unit Dimensions Unit Length- 74.4 in Unit Width: 46.6 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 562 lb Medium Heat 63 lb Total Operating Weight: 625 lb Unit Unit Voltage-Phase-Hertz: 230-3-60 Air Discharge. Vertical Fan Drive Type- Direct Actual Airflow: 2400 CFM Site Altitude. 39 ft Cooling Performance Condenser Entering Air DB• 90.0 F Evaporator Entering Air DB• 78.5 F Evaporator Entering Air WB: 64.5 F Entering Air Enthalpy: 29.56 BTU/lb Evaporator Leaving Air DB• 55.9 F Evaporator Leaving Air WB• 54.6 F Evaporator Leaving Air Enthalpy 22.93 BTU/lb • Gross Cooling Capacity: 71.58 MBH Gross Sensible Capacity' 58.29 MBH Compressor Power Input: 4.94 kW Coil Bypass Factor- 0.107 Mixed Air Outdoor Air Airflow- 420 CFM Outdoor AirDB• 90.0 F Outdoor Air WB• 67.0 F Outdoor Air Htg.Temp.: 22.0 F Return Air DB• 76.0 F Return Air WB: 64.0 F Return Air Htg.Temp.: 70.0 F Heating Performance Heating Airflow- 2400 CFM Entering Air Temp: 61.6 F Leaving Air Temp: 95.6 F Gas Heating Input Capacity: 110.0 MBH Gas Heating Output Capacity: 88.0 MBH Temperature Rise: 34.0 F Thermal Efficiency(%). 80.0 Supply Fan External Static Pressure' 0.80 in wg Fan RPM- 2302 Fan Power- 1.29 BHP NOTE: Selected IFM RPM Range:253-2530 Electrical Data Packaged Rooftop Builder 1 .49y Page 8 of 12 Performance Summary For rtu-1 Project: -Untitledl1 03/30/202C Prepared By: 11:05AN Voltage Range: 187-253 Compressor#1 RLA. 17.5 Compressor#1 LRA• 136 Indoor Fan Motor Type• MED Indoor Fan Motor FLA• 4.5 Combustion Fan Motor FLA(ea)• 0.48 Power Supply MCA: 28 Power Supply MOCP(Fuse or HACR)• 45 Disconnect Size FLA• 27 Disconnect Size LRA: 146 Electrical Convenience Outlet: None Outdoor Fan[Qty/FLA(ea)]: 1 /1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels,db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.8 89.4 85.6 125 Hz 84.5 81.1 84.7 250 Hz 78.7 72.6 80.5 500 Hz 76.3 68.4 76.0 1000 Hz 73.3 70.4 72.4 2000 Hz 71.4 62.1 68.0 4000 Hz 66.3 54.6 62.8 8000 Hz 61.5 49.2 59.3 A-Weighted 79.5 73.9 79.0 • Advanced Acoustics Wi 1414 © I i © �: \ [""1"----"11 \ 4C ' 0 0 -1.3.-) ._/:-‘) Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information Octave Band Center Freq.Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA Packaged Rooftop Builder 1.49y Page 9 of 12 Performance Summary For rtu-1 Project:-Untitled11 03/30/2020 Prepared By: 11:05AN C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 Lp D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center,LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit,LpA Calculation methods used in this program are patterned after the ASHRAE Guide;other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program,it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space,an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve 2.0 '----.000 RPM 1200 RPM 2400 RPM \ 2600 M 28 RPM 1.9 1.8 = \ 1.7 fVM 1 qPM ` \ 1.6 \ 1.5 '-''-N_''NN\ \ \ \ \ . / 1.2 . _________=------ (1.)1.1 1400 RPM y1.0 -� N\N\\\\t \ in2 0.9 \` ' 2.11= IP L030.8 iLW H�'M \ \ \ \ :' .� _ 0.7 `� 1. •BHP 0.6N. 1000 RPM 100 B 0.4 60o RPM \ \ t.50 \ 0.2 0.1 600 RPM \ \ _` 0.1 0.0 I I I I I I I I 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Airflow(CFM-thousands) RPM=2302 BHP=1.29 Maximum RPM=2836 Maximum BHP=3.00 SC-System Curve RP-Rated Point Packaged Rooftop Builder 1.49y Page 10 of 12 Unit Feature Sheet for rtu-1 Project: -Untitled11 03/30/202C Prepared By: 11`05AN CCarrie� 0 • WeatherMaker' - 48FC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS- 14 SEER 3,4,5 TONS,15 IEER 6 Ton STANDARD FEATURES INCLUDE: " '�" 'i°. 0 Puron(R-010A)HFC refrigerant 0 Meets or exceeds ASHRAE 90.1 energy efficiency levels 0 Scroll compressors with internal line break and overload protection • Single-stage coding capacity 04-06 models,Two Stage on 07 models 0 SEER's to 14.0,IEER's to 15.0 0 Aculrca refrigerant metering system on 04-06 models.DO.on 07 size models 0 Ecdusive non-corrosive composite condensate pan in accordance with ASHRAE Standard 62,sloping design,side or center drain 0 Standard coding operation up to 115°F(46°C)and down to 40°F(4°C) -down to 25°F(-4°C)with winter start kit. 0 Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection 0 Fully insulated cabinet 0 NEW Direct Drive-EcoSlue➢Technology Indoor fan system uses ASHRAE 0 Vane it Control Board with al fan design and ectrIntuitive quickonically commutated speed adjustment f Put-on. 0 Exclusive IGC solid-state control for on-board diagnostics with LED COMPLIANT error code designation burner control logic 0 Induced draft gas heat combustion design 0 Redundant gas valves with up to two stages of heating ' 0 Low pressure and high pressure switch protected. MAINTENANCE FEATURES: 0 Access panels with easy grip handles WEATHERMAKER SERIES 0 Innovative easy starting,no-strip screws on unit access panels 0 Two-inch disposable return air filters and Tool-less fitter at-s ns door 48FC units are single packaged gas heating,electric 0 New unit control board to facilitate simple safety circuit troubleshooting cooling units that are pre-wired and charged with Puron and simplified control box arrangement (R-410)refrigerant. The units are factory tested in both heating and cooling modes. 3-5 ton models use single INSTALLATION FEATURES: stage cooling capacity control.6 ton model uses two stage 0 Thru-they bottom power entry capability cooling capacity control 0 Single point gas and electric connections 0 Full perimeter base rail with built-in rigging adapters and fork slots 0 Field convertible from vertical to horizontal airflow STANDARD WARRANTY: 0 10-year heat exchanger-15-year stainless steel option 0 5-year compressor Approved and certified by. 0 3-tear SystemVri 0 1-year parts 0 Many optional upgrades also available MR:CERTIFIED. Use of the AHRI cennne OPTIONS INCLUDE BUT ARE NOT LIMITED TO: raves InAlra-e44 • Intelligent SystemVu communicating controls C US °M"b, • RTU Open Multi-Protocol DDC Controls r.e"v rc awe , rem Fri vae bit, • Supply and Return Air Smoke Detectors,high static motors of certi✓orb""tor M°,eeel • Louvered condenser coil guards preco.gob, e"alrectOry.21 • Disconnect switch and convenience outlet options • Stainless Steel heat exchanger option • Corrosion resistant coil coating. • MERV-8 Return Air Filters • Patented HumidFMiZer a adaptive dehumidification system. • Hinged access panels • Integrated economizer system.Low and Ultra Low Leak versions _ • Phase Monitor Protection • Condensate Overflow Protection For a complete list of options and accessories refer to the Product Data Catalog for this unit, Packaged Rooftop Builder 1 .49y Page 11 of 12 Spec Sheet for rtu-1 Project: -Untitled11 03/30/202C Prepared By: 11:05AN Packaged Rooftop Builder 1.49y Page 12 of 12