LTE Universal Wireless
Commercial Fire Alarm
Communicator "g
LE4O1OCF os�
Features That
Make a Difference:
• Uses LTE network for high-
speed, reliable and low-cost
communications to an IP
receiver Ensure your installations are
• Automatically switches to 3G future-ready, with LTE
(HSPA/HSPA+) if LTE service is Due to rapidly-evolving cellular or 1 hour(NFPA72 2013/2016)
not available technologies, 2G/3G network sunsets of the failure, or it can be used as
are already on the horizon—with part of a multiple communications
• Compatible with control panels some having already been completed. technologies(for example in
that communicate using Contact Now's the time to adopt and adapt. conjunction with a DACT).When
ID or SIA(300 baud)formats Switch to LTE today,to offer used as a back-up provision shall
• Full event reporting customers long-lasting investment be made to monitor the integrity of
• 4 on board inputs with NC, NO protection, and reduce your future each communication path and failure
or SEOL supervision truck rolls. of any communications path shall
The LE4010CF connects the alarm be annunciated at the supervising
• 4 on-board outputs (open station and at the protected premises
collector) control panel to the Cellular network within not more than 24 hours of the
and reports alarm signals directly to failure.
• Activation and initialization a monitoring station receiver
via website or mobile (Sur-Gard System I-IP/ll/IIVIV/5).The
How it Works
interface provided by C24 LE4010CF uses the Cellular network
Communications to ensure low-cost, high-speed and The LE4010CF can be used as
• View communicator status reliable alarm communications and is either a Sole Communicator or as a
directly from your mobile phone compatible with control panels that Backup Communicator.When being
to support on site or remote communicate using the Contact ID or used as a Sole Communicator the
troubleshooting SIA(300 baud)format. LE4010CF will replace the phone
line connection on the panel and
• Compatible with Sur-Garde The LE4010CF is compliant as soon as it detects that an alarm
System I-IP/II/III/IV/5 monitoring with the latest requirements for needs to be transmitted it will send
station receivers Communications Methods as per the alarm across the Cellular network
• UL864 and NFPA72 2010, 2013, immediately.When being used as a
Includes UL listed power and 2016 editions. It can be used
supply, transformer and 7 Ah in Fire Monitoring applications as a backup the communicator asQPsses
rechargeable battery single communications technology, the connection to the PSTN phone
line, and only in the event of a phone
• UL 864 listed in which case any failure of the line failure will it send all alarm traffic
CSFM listed communications path shall be
• across the Cellular network to the
annunciated at the supervising station monitoring station.
within 5 minutes (NFPA72 2010)
communications
Contact your DSC distributor.
www.dsc.com I 1-888-888-7838
CSC
•
From Tyco Security Products
In instances where the control panel does not support CSFM Listing
Contact ID or SIA(300 baud),the LE4010CF has inputs pre The LE4010CF has been approved by the California State Fire
set to transmit fire alarm,fire supervisory or system trouble. Marshal(CSFM)pursuant to Section 13144.1 of the California
Alarm signals are transmitted directly without the need of Health and Safety Code.
a clearinghouse to the IP linecard of the monitoring station
receiver(Sur-Gard®System I-IP/II/III/IV/5). Ordering Information:
Activating & Initializing the Unit LE4010CF-AT Universal Wireless Commercial
Fire Alarm Communicator
Activating and initializing the LE4010CF can be done using the
website interface provided by C24 Communications. Rate Plan
No special tools are required.
Cost-effective rate plans have been negotiated and are
Mobile Site for Easy Installation and available through authorized master resellers. Contact your
Comprehensive Maintenance monitoring station or visit www.connect24.com to find a
master reseller.When used as a sole communicator, the
C24 Communications mobile site (m.connect24.com) LE4010CF requires use of the 4MB (NFPA72 2010)or 500kB
makes the installation a simple process and offers intuitive (NFPA72 2013/2016)rate plans to support the supervision
trouble-shooting features, cutting down on time and cost requirements.
allocated to maintenance.
Specifications
® Dimensions 11-1/2" x 10"x 3"
C. o s 0 (290 mm x 254 mm x 75 mm)
Input Voltage 120 VAC
Current Draw 200 mA(standby)
® f 400 mA(transmitting)
',+01"" Operating Environment 32°to 120° F(0°to 49°C)
Weight 12.8 lbs(5.8 kg)
UL Listing
Optional Acessories
The LE4010CF is UL listed under File S4019, Listing guide
UOXX, as a sole or backup communicator for Commercial Fire Model Description
monitoring installations.When used as a sole communicator LTE-15ANT 15 ft extension antenna
under NFPA72 2010 guidelines the LE4010CF will send
its heartbeat once every 97 seconds ensuring that three LTE-25ANT 25 ft extension antenna
heartbeats will be received at the supervising station within LTE-50ANT 50 ft extension antenna
the 300 second window.When used as a sole communicator
under NFPA72 2013/2016 guidelines the LE4010CF will send
its heartbeat once every 5 minutes to monitor connectivity
with the supervising station within the 1 hour window. When
used as a backup communicator the LE4010CF will monitor
the other communication method(DACT)and send a daily
test transmission to the supervising station.