PFI2020-00232 'PIa CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT
s COMMUNITY DEVELOPMENT Permit#: PFI2020-00232
Date Issued: 07/14/2020
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421
Parcel: SEG1532
Jurisdiction: Tigard
Site address:
Subdivision: Lot:
Project: PGE Job#M2897282
Project Description: SEG 1532. Install street light pole 6652.
Class of Work: FEES
Description Date Amount
Type 1 -Utilities(gas, electric, data)
Total
Owner:
REQUIRED INSPECTIONS
Call 503-639-4175 for the IVR inspection request line or visit the City of
PHONE: Tigard website at www.tigard-or.gov to schedule inspections online.
Contractor:
PHONE:
Applicant:
RICO TORRES SOLIS
2213 SW 153RD AVE
BEAVERTON, OR 97003
PHONE:
Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact
information of responsible parties before beginning work.
Permittee/Applicant a
Signature: a pp() c 3 --
Issued By: r-�Af AE
Special Conditions(See Attached) l/
Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY
Conditions for PFI2020-00232
Type: Condition Name: Status: Severity:
PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice
Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code, and the terms of
any agreement with the City of Tigard regarding work to be done pursuant to this permit.
PFI_Utilities 02-WORK SITE AREA Applied Notice
The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The
spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited
and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up
and suspension of work to accomplish clean-up.
PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice
Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean
Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to
accomplish effective erosion control.
PFI_Utilities 04-WORK SITE REPAIRS Applied Notice
Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings,mailboxes,etc.shall be
reinstalled or replaced,with like kind of material.Obtain City approval of restoration work.
PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice
Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices
[MUTCD]for Streets and Highways", U.S. Dept.of Transportation, FHWA,current edition,American Traffic Safety Services
Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OUCH].
PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice
Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work
area. Traffic control devices,flag persons,etc.,shall be in place prior to initiation of construction work and shall be
effectively maintained.
PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice
Public roadway shall not be closed to traffic,at any time,without obtaining written approval from the City Engineer. The
applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and
area wide Emergency Services:503-629-0111 (Tigard Police Dept., Tualatin Fire& Rescue)and to 503-962-8140 (Tri-Met)
and 503-431-2345 (Tigard School District)and other service providers impacted by such closure.
PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice
Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign
at each end of the construction area 72 hours(min.)before initiation of construction work.
PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice
Access to existing properties shall be maintained at all times, including normal delivery service and mail service.Obtain City
approval of any access closures.
PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice
Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City.
PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice
Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the
City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized
by the City Engineer.
PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice
The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to
assure public safety.
PFI_Utilities 13-DRAINAGE CONTROL Applied Notice
Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and
the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective
drainage control.
PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice
Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR
952-001-0100 through OAR 952-001-0080.Copies of said rules may be obtained from the Center by calling 503-246-1987.
If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit
holder's expense.
PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice
Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole
before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at
the applicants expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work
with affected utility agencies.
PFI_Utilities 16-TEMPORARY PATCH Applied Notice
A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance
approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is
liable for hazards or damage resulting from the prosecution of the work.
PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice
Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary,as determined by
the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit.
Corrective work shall be done at the applicant's expense.
PFI_Utilities 19 -PRECONSTRUCTION MEETING Applied Notice
Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert
Phone#>,to establish a preconstruction meeting.
PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice
The applicant shall notify the City's Inspector twenty-four(24)hours prior to commencing work, prior to any staged
inspection, and after completing work covered by the permit.
PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice
A copy of the permit including a Certificate of Insurance, and all attachments,and a copy of the approved construction plan
and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and
provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and
specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work
performance.
PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice
Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector.
PFI_Utilities 23-MONUMENT PROTECTION Applied Notice
Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's
expense.
PFI_Utilities 24 -VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice
The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or
construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense.
PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice
Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2) persons who have
authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The
applicant shall notify the City Inspector, in writing, of any/all assignment changes.
PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice
Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed
easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to
obtain or provide for proof of right-of-entry or easements.
PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice
Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction
activity.
PFI_Utilities 28-AS-BUILT DRAWING Applied Notice
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements,including any revision made to the previously approved
construction plans and, also, any improvement which may impact an existing public system or facility,shall be provided to
the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of
Compliance).
1,2,3,4,5 28-AS-BUILT DRAWING
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to
the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of
Compliance).
One as-built drawing showing all new public improvements, including any revision made to the previously approved
construction plans and,also,any improvement which may impact an existing public system or facility,shall be provided to
the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of
Compliance).
PFI_Utilities 31 -OTHER Applied Notice
Other
RECEIVED
JUN 3 0 2020
City of Tigard CITY OF TIGARD PFI#: 2020-00232
m _ ENGINEERING DEPARTMF jT NNING/ENGINEERING
TIGARD Public Facilities Improvement (PFI) Permit
PROJECT INFORMATION
PGE Job # M2897282 TYPE OF WORK
Project name: 8 TYPE 1-Franchise Utility Work
Brief description of project: performed by ice,PGE, or utility
agency
install street light pole 6652 ❑ 'TYPE 2-ROW Sidewalk/Driveway/Sewer
Work performed for the purpose of:
• Sidewalk installation or repair
• Driveway approach installation and repair
SITE INFORMATION • Sanitary sewer lateral installation and
main line tap
Location (address if available):
❑ TYPEScale Development Work
13755 SW 114TH Ave
S E G 15 3 2 performermedd with land use approval which
includes any of the following:
• Subdivisions or Partitions
APPLICANT INFORMATION • Street widening
Name: PGE Linda Ott • Mainline installation for sanitary sewer.
storm sewer, 'Tigard water, and Tigard
Mailing address: 2213 SW 153rd DR water service area
City/State: Beaverton, OR Zip: 97003 ❑ TYPE 4-Small Cell Technology
Phone:
503.612.6093 ❑ TYPE 5-Tigard Triangle
Email: crewcoordination-western@pgn.com Phone: 503.464.7777 NOTE: Type 1 and 2 applications may be
Contact name: Rico Torres Solis emailed to rowpermits n tigard-or.gov.
Phone: 503.403.9084 Email: crewcoordination-western@pgn.com
CONTRACTOR INFORMATION 0 Same as applicant
Name: pge crew CCB Number:
Mailing address: City/State: Zip:
Phone: Email:
ENGINEER INFORMATION
Name:
Mailing address: City/State: Zip:
Phone: Email:
ADDITIONAL INFORMATION
Estimated value of work is required(if over$5,000):$ (within the public right-of-way)
Is work related to a LAND USE DECISION? Oyes ❑No Case number:
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 1 of 4
APPLICANTS
NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for
work,if required by the city pursuant to TMC 15.04.140.
* With the exception of a utility operating pursuant to a valid franchise or license with the City of Tigard,when the owner and the applicant
are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner
or an agent of the owner. The owner must sign this application in the space provided or submit a written authorization with this
application. Franchised or Licensed Utilities are not required to obtain the owner's signature on the application.
I,the applicant, certify that:
• To the best of my knowledge, all the information provided within this application package is complete and
accurate.
• The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the
subject property.
• If the application is granted,I will exercise the rights granted in accordance with the terms and subject to all the
conditions and limitations of the approval.
Lat . Opt Linda Ott for Rico Torres Solis 6.30.20
Applicant's or authorized agent's signature Print name Date
Property owner's signature (if required) Print name Date
STAFF USE ONLY
Case No: PFI2020-00232 Permit fee: _d - Received by: AL Date: 6/30/20
Approved by: -7?e iY ig_ Date: 74 /202d Notified by: Date:
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 2 of 4
DEVELOPMENT ENGINEERING FEES
Public Facility Improvement(PFI)Permit:
INITIAL PFI PERMIT FEE
Part 1: Required submittal fee is 10%of the Net PFI Permit Fee.See below for calculations.Minimum of$300.
NET PFI PERMIT FEE
Part 2: All non-water system improvements engineer's estimate X 7%(less the initial PH Permit Fee).
WATER LINE CONSTRUCTION FEE
Part 3: All public water system improvements engineer's estimate X 12%.
FOR STAFF USE ONLY FOR STAFF USE ONLY
TYPE 4: SMALL WIRELESS FACILITY TYPE 1—3:DETAILED SUBMITTAL
CHECKLIST REQUIREMENTS
Does applicant have a right-of-way license? ❑Yes 0 No TYPE 1 AND TYPE 2-Must include a sketch
showing:
Under the wireless facilities standards,is the proposal ❑ Dimensions
considered?(check all that apply): ❑ Small Cell 0 Macro ❑ Street Name
❑ Site Address
How many install sites are proposed as part of this permit
application?
TYPE 3-Must provide 4 sets of plans (sized 24 x 36
or 22 x 34) and an electronic version of all submittal
The proposed equipment is located on which of the following items. The plans must that include:
❑ Public Right-of-Way ❑Private Property
❑ Cover—Site,Vicinity,Abbreviation,Legend
If equipment is to be located on private property,describe the El General Notes(City,Water,Sewer,etc.)
type&use: ❑ Street(Plan,Profile)
❑ Water,Storm and Sanitary(Plan Profile)
❑ Water Quality Facilities
❑ Grading
❑ Landscaping/Tree Plan
❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,
Sanitary,Water,Signage,Street Lights,etc.)
❑ Details
❑ Traffic Sight Distance
❑ Signing and Striping
❑ Street Light Plan and Photometric
El Engineers seal/signature
❑ Sheet label(project land use name,revision and plan
log block,dates and sheet numbers.)
❑ Engineer's Construction Estimate
Additional Submittals
(per land use conditions,if applicable)
❑ Traffic Report
❑ Storm water Drainage Calculations
❑ Geotechnical Report
❑ Preliminary Access Report(Sight Distance)
❑ Proposed Plat
❑ Pathway Design
❑ Water Provider Approval
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 3 of 4
T � 11 — Ni .. S (
Edge of Pavement
�- DLtCh . .. 1/1'.Streetlight
•� n Rant Dram � �►'i`►.
I ;�
Tiop'oYtf•Sj'e�TiAe-- �I
T-
c. r 1
1, ai •
a! 1 Eaislung House I
< cj I Existing
. Driveway
r' C�
xi 01 ! _ 1
r .C
of / CI
0 `—I
H
Ur
2
OI
i
e°r 1 1
�
1 I \ Existing Shop
1
:4:
I
t iPowerpete I I t : 1
�. o • e
I
-''riurt-i1^0
r„,..,
! Fire Hy crart(FH)
I
1 I Scale. t-_3.
I
i I
i I
i I
TYPE 1 AND TYPE 2:
MINIUM SKETCH REQUIREMENTS (Put N/A if not applicable)
North arrow Property lines&dimensions Existing utilities locations
(sewer, storm,water)
Street&street names All existing structures
Proposed work Existing curb or edge of pavement Utility&street light poles
Existing S/W or D/W apron Slope of property Trees
City of Tigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigaxd-otgov • 503-718-2421 • Page 4 of 4
11245 LIGHTING LEGEND
13 ew
0B4NbeRn 51—}X 4540.5 445LmE3
mpe
A REPLACEIIYIRF.fa WOOD VALE/MOI/n0TDVLI
µl4N3Rl0 sown a COHNII How
111'55 • FIBERGLASS M w BL941c POLEor Fr
\ \y CJxxFC!Di rRVOt!.11T0
\ Ly ITY MAP I4 I.
13AJ l .✓y N. S
19 u t I / *fin f
NOTE: j` I < lr,m,.
m
LIGHT AND POLE WERE �ti ALE `"""" i `� '
REMOVED UNDER WO M2890643 •••' 3'•a 3 1.
\\\\i 12rs r IB 1 Irn"lll4 pt!
13T30 1 i 1 ` rr 1 11 ' .
Ins, ®s 9 1 i 3 E {�E'0 �� I� ' /
\, 1s I ASSET/193617 13150 t'T �a r�.�, $
JI•'43 3 Y `Vp•C
♦ h ' 3
Q - F I•..x.., r„37E �! PELF PEEP:,.. ., L .
(1,f130 . ..� .. a _�,
ew,4`€ I IE a
1 i I ��+ �..,� e
A TSA -
.: 3 Ir IF
13380 -
ANY DEVIATION FROM THIS DESIGN MUST
11335 RE APPROVED BY THEPGE PROJECT MANAGER
(ul uI IBFBl1EY0Y DIN
/' I T Ieera�a�,�' 1°wN°,,:a erw°1'Im""o u'a!ro 811
SAFETY Ammo/anal
11./1_Alatia1411.
551mown ♦-1-OW \IRS, nr rlo tINIO/Fano`[rook B iru`liR OrEL mly. N
Apt SW VIEW000NT CT w zE .:L arF rPioP ro eKi9wrwx
EreClnerouBEIMWYfgPOLE POE GONBTRUCTLMI DRAWEES
♦ r.
_ — "" AS 6UILTVERIFICATMN B f1USC VIOLATIONS CORRECTED
..,.. I I Formlren: Dab:
General Foremen: Dais:
.,. SORM£AG REVIEW IASNULTBYOEGIGNERSCALE Nw
138A� \ Im�~ �4/2020 40B Pp`""1070001 IF 10 0 00 0 81 06 I 0A 891282
INSTALL SCAMP FUSES M SECONDARY PEDESTALS OR SECONDARY City of Tigard PLR 5602
VAULTS(WHICHEVER HST LT POINT OF ATTACHMENTI FOR EACH „: YYI /'1 ` TGARO-TIGARD 13 Iii 11
SWEET LIGHT PERTBO CONSTRUCTION STANDARD LC-IISSO .. [ ry 11� -•.,`.::.,w.. /pGE/L0Cn11WN
RIGHT-OF-WAY PERMIT NOTICE: fit 13705 SW 11ATH Ave,TIGARD
PD N
A PERMIT FROMRIGHT-OF-WAS
THE LOLL/URISDICOON IS MED. O BEFORE ANT I0T1oN IFCEPeuMTAwTB1M Replan EOL 1010 and caNW,Y®2AW SHEET
WORK IN THE RIGHT-OFWAS MAY BE PERFORMED ONLY POE APPROVED _ 00Uur BECn014 92$0MIM
CONTRACTORS AND CONTRACTORS WHO HAVE MADE OTHER SPECIAL ��--zr� WABHINGTONI021030 IAQB90G9 1OF1
AGREEMENTS WITH POE WILL BE ALLOWED TO WORK UNDER PGES PERMIT .... .. OESMNer Ps7244l S•By
fM THE CONTRACTOR MUST NOTIFY THE LOCAL/Om50R HON AB HOTMT 'r t'.us saw amp
t IBGD BOLTS BT2-fi01 LUIB BlAN00
NLn,o,BEFORE WORK IS TO BEGIN.A(OFF OF THE PERINI EMUS r Bf ON SITE_ _ �'^"r'^_ ..7=".m ertAR.Ve31040UL&MEG".-NLRIW1f30FBFM'E)
Page 78 2011 Edition
Work on Shoulder Diagram 210
Diagram 210 covers stationary work with work or parked equipment on the
shoulder. This diagram does not cover work on a freeway shoulder. See
Diagram 710 for Freeway Shoulder work.
1. Vehicles should be parked as far off the roadway as practical.
2. Use truck-mounted flashing warning lights on work and protection
vehicles. See Section 4.3—Lights and Lighted Signs for exceptions.
3. For added visibility, truck-mounted arrow boards or PCMS in caution
mode may be used.
4. Arrow panels in caution mode are recommended for work on roads
with posted speeds of 45 mph or greater and high traffic volumes,
greater than 2000 average daily traffic (ADT).
5. Requirements for signing and devices are shown in Table 5-2, below.
Table 5-2: Device and Signage Guidelines
Proximity to Edge of Traveled Way
More than 15 feet
or behind Barrier or Less than 15 feet
Guardrail
One advance warning sign is
Advance warning required and two signs are
Work in Place signs, devices, and recommended.
More than 1 Flour flashing warning Cone taper is required. Cones
lights are optional. along the edge of traveled way
are optional.
Work in Place Advance warning signs and devices are optional.
Less than 1 Hour
Sign Spacing and Buffer Lengths(feet)
Posted Spacing Between Signs Buffer
Speed A B C Space
20 50
25 100 100 100 75
30 100
40 350 350 350 150
45 180
50 500 500 500 210
55 250
Chapter 5 December 2011
2011 Edition Page 79
Work on Shoulder Diagram 210
t
•
•
• A • •
• • •
(Optional)
• Ill
Protection Vehicle
• III w/TMA(both Optional)
See Chapter 4
•
• Buffer
•
•
• *
•
•
A
,' ROAD \ SHOULDER.,..•.
WORK OR WORK
AHEAD/ AHEAD/
Initial Warning Sign
f *Use as appropriate-see Table 5-2
December 2011 Chapter 5