Report c I°czOZc,-dvv7G
lz0/o VitW
RECEIVED
AFP Systems,Inc. JUN 9 2020
;'0
Automatic Fire Protection CITY OF TIGARD
19435 SW 129fhAvenue BUILDING DIVISION
Tualadu,OR. 97062
SYSTEMS )
(503)692-9284
(503)692-1186 fax
SUBMITTAL
Project Name:
Aspen Ridge Residence
12010 SW Viewcrest Court
Tigard, OR 97224
For:
Odyssey Development, LLC
9340 SW Salmon Street
Portland, OR 97225
,..... , .
. . , , ,
.. . ..
. . . . .
;y.a
NFPA 13D PUMP & TANK SYSTEM
Designed & built specifically to meet NFPA 13D requirements, the
H2hOme®is everything you need to provide required pressure&flow
to a residential fire sprinkler system in a sleek,all-in-one package. As
with all of our 13D pump & tank systems, the H2hOme® comes
standard with a stainless steel pump and all non-ferrous components i
to protect against corrosion and ensure longevity.Additionally, this to
is the only stand-alone system on the market with an easily removable
slide-out pump. Created with contractors in mind, our 29"slim tank ,. n`:
can be carried through any typical doorway -with reduced weight
when the pump is removed. The H2hOme® also includes a riser
manifold kit making installation even easier. A control panel can
be added with indicator lights, alarm functionality and a simple
"push-to-test" button. The H2hOme® is quite simply the most
efficient, reliable and easiest to install pump & tank system
available-backed by the best customer service&technical support
in the fire sprinkler industry.
e All-In-One Unit With Small Footprint • Designed & Built For Fast Installation
• 29" Wide/425 Gallon Narrow Water Tank • Riser Manifold Kit Included .
• Removable Stainless Steel Pump • Advanced Control Panel (Optional)
4 All Non Ferrous Components • Lifetime Customer Service & Tech Support
Pump Motor Tank Size Dimensions (in)
Model _
HP PH HZ Volts Amp Draw (gal) L W H
H2H425-E01 3/4 Single 60 240 5.2 425 i 68 29 76
H2H425-E03 11/2 Single 60 240 9.1 425 68 29 76
H2H425-A04 2 Single 60 240 11.2 425 68 29 76
H2H425-A06 3 Single 60 240 12.8 425 68 29 76
Optional Accessories: 6 29.00
"' ' Control Panel: The optional control panel puts the --
='=- functionality of the H2hOme®at your fingertips.Visual displays
r e • for the unit's status are present as well as a simple push-button
to test the functionality of the pump. 75.62
failgiallaidia
Alarm: The hom/strobe will alert in the event of system activation.Includes apwili
�i
ei30'power cord and can be wall mounted anywhere in the home. System mustinclude the control panel for alarm function. _ tiro _
®WARNING:Cancer and Reproductive Hann-www.o65waminas.ca.aov
***G ==gEir h2home.us I generalairproducts.com
** AIR PRODUCTS 800-345-8207
• ,s. w„..
, ,
...,, ,
H ,
, ,,
{T
2
NFPA 13D PUMP & TANK SYSTEM
Bulkhead r __ - Bulkhead For Fill
For Overflow - ""` With Float Valve
Bulkhead ,. Advanced Control
& Test line Panel(Optional)
r''
Discharge 425 Gallon Narrow
Check Valve Tank(29"Wide)Industrial Duty r ,,- Riser Manifold
Pressure Switch r',r
Pump Isolation
System Pressure t. Valve
Gauge
�� Stainless
%X _ -- Steel Pump
Pump Test ,.:
Valve —
3
"" -- System Drain
Tank Isolation i" ;;arid'!'%
Valve Tank Drain
H2H425-E01 Performance H2H425-E03 Performance
GPM 20 25 30 35 GPM 20 25 30 35
PSI 26 24 21 18 PSI 48 45 39 34
H2H425-A04 Performance
GPM 0 20 25 30 35 40 45 50 55 60
PSI 61 57 54 52 49 46 43 39 36 33
H2H425-A06 Performance
GPM 0 20 25 30 35 40 45 50 55 60
PSI 72 68 65 63 60 58 55 51 48 49
**- __-____ h2home.us ) generalairproducts.com
** AIR PRODUCTS 800-345-8207
Worldwide www.tyco-fire.com •
t11111
Contacts
RAPID RESPONSE Series LFII Residential
4.9 K-factor Concealed Pendent Sprinkler
Flat Plate, Wet Pipe and Dry Pipe Systems
General • Wet and dry pipe sprinkler systems
for the residential portions of any
Description occupancy per NFPA 13
The Series LFII Residential Concealed
The TYCO RAPID RESPONSE Series Pendent Sprinklers have been designed . "'„,
•
LFII Residential 4.9K Concealed with heat sensitivity and water distri-
Pendent Sprinklers(TY3596)are dec- bution characteristics proven to help
orative,fusible solder sprinklers,avail- in the control of residential fires and to
able in both ordinary 160°F(71°C)and improve the chance for occupants to `le%
intermediate 212°F (100°C) tempera- escape or be evacuated.
ture rated configurations. They are The Series LFII Residential Con-
designed for use in residential occu- cealed Pendent Sprinklers (TY3596)
pancies such as homes, apartments, are shipped with a Disposable Protec-
dormitories,and hotels. tive Cap. The Protective Cap is tem- Consequently,the Series LFII Residen-
The cover plate assembly conceals porarily removed for installation, and tial Concealed Pendent Sprinklers offer
the sprinkler operating components then it can be replaced to help protect the features of non-water filled pipe in
above the ceiling.The flat profile of the the sprinkler while the ceiling is being addition to not having to increase the
cover plate provides the optimum aes- installed or finished.The tip of the Pro- number of design sprinklers(hydraulic
thetically appealing sprinkler design. tective Cap can also be used to mark design area)for systems designed to
In addition, the concealed design the center of the ceiling hole into the NFPA 13, 13D,or 13R.
of the Series LFII Residential Con- plaster board, ceiling tiles, and so on,
cealed Pendent Sprinklers provides by gently pushing the ceiling product NOTICE
1/2 in. (12,7 mm) vertical adjustment. against the Protective Cap. When the The Series LFII Residential Concealed
This adjustment provides a measure ceiling installation is complete the Pro-
Pendent Sprinklers(TY359fi)described
of flexibility when cutting fixed sprin- tective Cap is removed and the Cover herein must be installed and main-
kler drops. Plate Assembly is installed. tained in compliance with this docu-
The Series LFII Residential Concealed Dry Pipe System Application ment and with the applicable standards
Pendent Sprinklers are intended for use The 160°F (71°C) temperature rated of the NATIONAL FIRE PROTECTION
in the following scenarios: Series LFII Residential Concealed ASSOCIATION (NFPA), in addition to
• Wet and dry pipe residential sprin- Pendent Sprinklers offer a laboratory the standards of any authorities having
kler systems for one and two lam- approved option for designing dry pipe jurisdiction.Failure to do so may impair
ily dwellings and mobile homes per residential sprinkler systems,whereas, the performance of these devices.
NFPA 13D most residential sprinklers are labora- The owner is responsible for main-
tory approved for wet systems only. taining their fire protection system
• Wet and dry pipe residential sprin Through extensive testing, it has and devices in proper operating con-
ersystems for residential occupan- been determined that the number of dition. Contact the installing contrac-
ci height to per NFPA 13R including four stones in design sprinklers (hydraulic design for or product manufacturer with any
in area) for the Series LFII Residential questions.
Concealed Pendent Sprinklers need
not be increased over the number of Sprinkler
IMPORTANT design sprinklers (hydraulic design
Refer to Technical Data Sheet area)as specified for wet pipe sprinkler Identification
TFP2300 for warnings pertaining to systems,as is accustomed for density/
regulatory and health information. area sprinkler systems designed per Number (SIN)
NFPA 13.
Always refer to Technical Data TY3596
Sheet TFP700 for the `INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 6 SEPTEMBER 2019 TFP442
TFP442
' Page2of6
• Technical BODY SEALING
Data (1/2"NPT) ASSEMBLY
Approvals CAP--
UL and C-UL Listedli=t2;"/
SPRINKLER
NYC Approved under MEA 44-03-E-2NSF WRENCHING
Certified to all requirements of _ AREA
NSF/ANSI 61 SADDLE —
Australian WaterMark Certified
The TYCO RAPID RESPONSE Series LFII SUPPORT COMPRESSION
IT
Residential Concealed Pendent Sprinklers CUP WITH I I SCREW
are Listed only when installed with LFII Con- ROLL FORMED
cealed Cover Plates having factory-applied
finishes. THREADS
Sprinklers and Cover Plates are separately '� LEVER
ordered. See the Ordering Procedure � tt77
section for more information. GUIDE /
Maximum Working Pressure PIN
175 psi(12,1 bar) /1
SOLDER LINK
ELEMENT
Discharge Coefficient GUIDE PIN
K=4.9 GPM/psi'(70,6 LPM/bar') HOUSING
Temperature Rating - _ DEFLECTOR
Ordinary DEFLECTOR r, ' : OPEPO RAT VD
)
160°F(71°C)Sprinkler/
139°F(59°C)Cover Plate SPRINKLER
NOTE:Maximum Ambient Ceiling Temperature for the ASSEMBLY
ordinary temperature configuration is 100°F(36°C) THREAD INTO RETAINER
Intermediate* SUPPORT WITH THREAD
212°F(100°C)Sprinkler/ CUP UNTIL DIMPLES
165°F(74°C)Cover Plate SURFACES ' CI (111)
�'
'For wet pipe systems only FLUSH WITH
NOTE:Maximum Ambient Ceiling Temperature for the I
intermediate temperature configuration is 160°F(65°C) CEILING [ EJECTION
ISPRING
I
Vertical Adjustment
1/2 in.(12,7 mm) __
-
\L�
Finishes
See the Ordering Procedure section SOLDER COVER PLATE COVER
Physical Characteristics TAB ASSEMBLY PLATE
Body Brass FIGURE I
Cap Bronze RAPID RESPONSE SERIES LFII RESIDENTIAL
Saddle Brass CONCEALED PENDENT SPRINKLER(TY3596)
Sealing Assembly..Beryllium Nickel w/TEFLON
Soldered Link Halves Nickel
Lever Bronze allowing the sprinkler to activate and idential Concealed Pendent Sprinklers.
Compression Screw Brass flow water. may be utilized in dry pipe systems,per
Deflector Copper or Brass
Guide Pin Housing Bronze the UL and C-UL Listing,
Guide Pins Stainless Steel or Bronze Design Criteria Refer to Technical Data Sheet TFP485
Support Cup Steel
Cover Plate Copper/Brass" The TYCO RAPID RESPONSE Series about the use of residential sprinklers
Retainer Copper in residential dry pipe systems.
Cover Plate Ejection Spring.... Stainless Steel LFII Residential Concealed Pendent
Brass Cover Plate is offered for Intermediate Tem-
perature Sprinklers (TY3596) are UL and C-UL Ceiling Types
165°F(74°C)only. Listed for installation in accordance Smooth flat horizontal, beamed, or
Operation with this section. sloped in accordance with NFPA 13D,
/� Note: When conditions exist that are 13R,or 13 as applicable.
When exposed to heat from a fire,the outside the scope of the provided cri- Hydraulic Design
Cover Plate,which is normally soldered feria,refer to the Residential Sprinkler (NFPA 13D and 13R)
to the Retainer at three points, falls Design Guide TFP490 for the menu- For systems designed to NFPA 13D or
away to expose the sprinkler assembly. facturer's recommendations that may NFPA 13R,the minimum required sprin-
At this point the Deflector supported by be acceptable to the authority having kler flow rates are given in Tables A and
the Arms drops down to its operated jurisdiction. B as a function of temperature rating
position. The fusible link of the sprin- System Types and the maximum allowable coverage
kler assembly is comprised of two link Per the UL and C-UL Listing, the areas.
halves that are soldered together with 160°F (71°C) and 212°F (100°C) LFII The sprinkler flow rate is the minimum
a thin layer of solder. When the rated Residential Concealed Pendent Sprin- required discharge from each of the
temperature is reached, the solder klers may be utilized in wet pipe total number of"design sprinklers"as
melts and the two link-halves separate systems.Only the 160°F(71°C)LFII Res- specified in NFPA 13D or NFPA 13R.
TFP442 , •
Page 3 of 6 •
WET PIPE SYSTEM
Minimum Flow and Residual Pressure''
Maximum Maximum
Coverage
Temp.Rating
Spacing 160°F(71 C),212°F(100C) Minimum
ft x ft (m) Flow Pressure Deflector to Installation Spacing
(m x m) GPM Ceiling Type ft
Psi (m)
(LPM) (bar)
12 x 12 12 13 7.0
(3,7 x 3,7) (3,7) (49,2) (0,48) Smooth
Ceilings
14 x 14 14 13 7.0 7/8 to 1-1/8 In.
(4,3 x 4,3) (4,3) (49,2) (0,48)
Beamed
16 x 16 16 13 7.0 Ceilings per 8
(4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2 4)
13R,or13.
Installed in
18 x 18 18 17 12.0 beam
(5,5 x 5,5) (5,5) (64.3) (0,83) 7/8 to 1-1/8 in.
below bottom
20 x 20 20 20 16.7 of beam
(6,1 x 6,1) (6,1) (75,7) (1,15)
Notes:
1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage
area for which hydraulic design criteria are stated.
2. Requirement is based on minimum flow In GPM(LPM)from each sprinkler.The associated residual pressures are calculated
using the nominal K-factor.See Hydraulic Design under the Design Criteria section.
3. For NFPA 13 residential applications,the greeter of 0.1 GPM/ft°over the design area or the flow in accordance with the criteria in
this table must be used.
TABLE A
WET PIPE SYSTEM
SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER(TY3596)
NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA
DRY PIPE SYSTEM
Minimum Flow and Residual Pressure 2.a
Maximum Maximum
Coverage Spacing Ordinary Temp.Rating Minimum
Area' ft 160 F(71°C)
ft x ft Deflector to Installation Spacing
(m x m) (m) Flow
GPM Pressure Ceiling Type ft
Psi (m)
(LPM) (bar)
12 x 12 12 13 7.0
(3,7 x 3,7) (3,7) (49,2) (0,48) Smooth
Ceilings
14 x 14 14 14 8.2 7/8 10 1-1/8 in.
(4,3 x 4,3) (4,3) (53,0) (0,57)
Beamed
16 x 16 16 15 9,4 Ceilings per 8
( ,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13 or Concealed (2 4)
4 13R,or 13.
Installed In
18 x 18 18 18 13.5 beam
(5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 in.
below bottom
20 x 20 20 21 18.4 of beam
(8,1 x 6,1) (6,1) (79,5) (1,27)
Notes:
1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage
area for which hydraulic design criteria are stated.
2. Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated us-
ing the nominal K-factor.See Hydraulic Design under the Design Criteria section.
3. For NFPA 13 residential applications,the greater of 0.1 GPM/ft=over the design area or the flow in accordance with the criteria in
this table must be used.
TABLE B
DRY PIPE SYSTEM
RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596)
NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA
TFP442
' ' Page 4 of 6
• 2-1/2"DIA. TEMPERATURE PROFILE AIR
(63,5 mm) 1/2"(12,7 mm) RATING DEPTH GAP
1/2" THREADED ORDINARY 3/16"(4,8 mm) 1/8"(3,2 mm) COVER PLATE OPERATED
NPT ADJUSTMENT INTERMEDIATE 5/32"(4,0 mm) 3/32" (2.4 mm) RETAINER SPRINKLER
i
\ FACE OF
_ `SPRINKLER SPRINKLER-
1-7/8"tt/4" FITTING SUPPORT CUP
(47,6 mm MOUNTING ASSEMBLY
t6,4 mm) SURFACE
� � E i__
I 4 5/8'(15,9 mm)
COVER- SPRINKLER-
RETAINER SUPPORT CUP PROFILE AIR \ 1-1/8"(28,6 mm)
ASSEMBLY ASSEMBLY DEPTH GAP
(SEE (SEE
3-3/16"DIA. : TABLE) TABLE) % DISPOSABLE DEFLECTOR IN
(81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION
FIGURE 2
RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3586)
INSTALLATION DIMENSIONS,PROTECTIVE CAP,AND ACTIVATED DEFLECTOR
The number of "design sprinklers" Operational Sensitivity WRENCH
specified in NFPA 13D and 13R for wet The sprinklers are to be installed rela- RECESS
pipe systems is to be applied when tive to the ceiling mounting surface as
designing dry pipe systems. shown in Figure 2.
Hydraulic Design Sprinkler Spacing ��1 'r••'`
(NFPA 13) The minimum spacing between sprin-
. For systems designed to NFPA 13,the klers is 8 ft (2,4 m). The maximum
number of design sprinklers is to be spacing between sprinklers cannot
the four most hydraulically demanding exceed the length of the coverage area „r
sprinklers.The minimum required dis- (see Table A or B) being hydraulically
charge from each of the four sprinklers calculated,for example,maximum 12 ft PUSH WRENCH
is to be the greater of the following: for a 12 ft x 12 ft coverage area,or 20 ft IN TO ENSURE
ENGAGEMENT
• The flow rates given in Tables A and for a 20 ft x 20 ft coverage area. WITH SPRINKLER
B as a function of temperature rating The Series LFII must not be used WRENCHING AREA
and the maximum allowable cover- in applications where the air pres- FIGURE 3
age area sure above the ceiling is greater than W-TYPE 18
• A minimum discharge of that below. Down drafts through the SPRINKLER WRENCH
0.1 GPM/ft2 over the design area Support Cup could delay sprinkler
comprised of the four most hydrauli- operation in a fire situation. Step 1. The sprinkler must only be
tally demanding sprinklers for actual installed in the pendent position and
coverage areas protected by the four Installation with the centerline of the sprinkler per-
sprinklers The TYCO RAPID RESPONSE Series pendicular to the mounting surface.
The number of design sprinklers speci- LFII Residential Concealed Pendent Step 2.Remove the Protective Cap.
tied in NFPA 13 for wet pipe systems is Sprinklers (TY3596)must be installed Step 3. With pipe thread sealant
to be applied when designing dry pipe in accordance with this section. applied to the pipe threads, and
systems. General Instructions using the W-Type 18 Wrench shown
Dry Pipe System Water Delivery Damage to the fusible Link Assembly in Figure 3, install and tighten the
When using the Series LFII Residen- during installation can be avoided by Sprinkler/Support Cup Assembly Into
tial Concealed Pendent Sprinklers in handling the sprinkler by the support the fitting. The W-Type 18 Wrench will
dry pipe sprinkler systems, the time cup only.Therefore,do not apply pres- accept a 1/2 in.ratchet drive.
for water delivery must not exceed 15 sure to the fusible Link Assembly. Step 4.Replace the Protective Cap by
seconds for the most remote operat- A 1/2 in. NPT sprinkler joint should be pushing it upwards until it bottoms out
ing sprinkler. obtained with a minimum to maximum against the Support Cup.The Protec-
Obstruction to torque of 7 to 14 lb-ft(9,5 to 19,0 N•m). tive Cap helps prevent damage to the
Water Distribution Higher levels of torque may distort the Deflector and Guide Pins during ceiling
Sprinklers are to be located in accor- sprinkler inlet with consequent leakage installation and/or during application of
dance with the obstruction rules of or impairment of the sprinkler. the finish coating of the ceiling.It may
• NFPA 13D, 13R, and 13 as applicable Do not attem t to tom ensate for also be used to locate the center of the
for residential sprinklers as well as with p P clearance hole by gently pushing the
the obstruction criteria described within insufficient adjustment in the Cover ceiling material against the center point
the Technical Data Sheet TFP490. Plate Assembly by under-or over- of the Cap.
tightening the Sprinkler. Readjust the
position of the sprinkler fitting to suit.
TFP442 . -
Page 5 of 6
Note:As long as the protective Cap Factory painted Cover Plates must not Limited ,
remains in place, the system is consid- be repainted.They should be replaced,
ered to be "Out Of Service." if necessary, by factory painted IVarrant
Step 5.After the ceiling has been corn-
p units. Non-factory applied paint may y
leted with the 2-1/2 in. 63 mm diam- adversely delay or prevent sprinkler
( ) operation in the event of a fire. For warranty terms and conditions,visit
eter clearance hole and in preparation www.tyco-fire.com.
for installing the Cover Plate Assembly, Do not pull the Cover Plate relative to
remove and discard the Protective Cap, the Enclosure.Separation may result. Ordering
and verify that the Deflector moves up Sprinklers which are found to be
and down freely. leaking or exhibiting visible signs of Procedure
If the sprinkler has been damaged and corrosion must be replaced.
the Deflector does not move up and Automatic sprinklers must never be Contact your local distributor for avail-
down freely,replace the entire sprinkler p ability.When placing an order,indicate
assembly.Do not attempt to modify or painted, plated, coated, or otherwise the full product name and part number
altered after leaving the factory. Modi- P/N .
repair a damaged sprinkler. fled or over heated sprinklers must be ( )
Step 6. Push on the Cover Plate replaced. Sprinkler Assemblies
Assembly until its flange comes in Care must be exercised to avoid Specify:Series LFII(TY3596)4.9K Res-
contact with the ceiling. damage before,during,and after instal- idential Concealed Pendent Sprinkler,
P/N(sPecfry):
Do not continue to push on the Cover lation. Sprinklers damaged by drop-
Plate Assembly such that it lifts a ping, striking, wrench twist/slippage, 160°F(71°C> 51-112-1-160
ceilingpanel out of its normal 212°F(100°C) 51-112-1-212
position. or the like,must be replaced.
If the Cover Plate Assembly cannot The owner is responsible for the Note:Sprinkler and Cover Plates are
be engaged with the Mounting Cup inspection,testing,and maintenance of Plate ly
rigsol information.See below for Cover
or the Cover Plate Assembly cannot their fire protection system and devices Plate ordering
be engaged sufficiently to contact the in compliance with this document, as Cover Plate Assemblies
ceiling, the Sprinkler Fitting must be well as with the applicable standards Specify: LFII Concealed Sprinkler
repositioned. of the NATIONAL FIRE PROTECTION Cover Plate Assembly, temperature
ASSOCIATION,for example, NFPA 25, rating (specify), (specify) finish, P/N
Care and in addition to the standards of any other (specify):
authorities having jurisdiction.Contact 139°F(59°c)
Maintenance the installing contractor or product Ivory(RAL1015) 56-204-0-135
manufacturer with any questions. Bright Chrome 56-204-1-135
The TYCO RAPID RESPONSE The owner must assure that the sprin- Beige(RAL1RA) 56-204-2-135
Series LFII Residential Concealed hangingp PureWhile(( L9010)' 56-204-3-135
klers are not used for any Sig
nal white RAL9003)•' 56-204-4-135
Pendent Sprinklers (TY3596) must be objects and that the sprinklers are only Grey White(RAL9002) 56-204-5-135
maintained and serviced in accordance cleaned by means of gently dusting Brown(RAL8028) 56-204-6-135
with this section. with a feather duster; otherwise, non- Black(RAL9005) 56-204-7-135
protectionsystemoperationin the event of a fire or triad- Brushed Bras 56-204-9-135
Before closinga fire Brushed Chrome 56-204-9-135
main control valve for maintenance vertent operation may result. Custom Paint 56-204-X-135
work on the fire protection system Automatic sprinkler systems should be 165°F(74°C)
which it controls, permission to shut inspected,tested,and maintained by a Ivory(RAL1015) 56-204-0-165
down the affected fire protection qualified Inspection Service in accor- Bright chrome 56-204-1165
system must be obtained from the dance with local requirements and/or Purge(hite R L ) 56-204-2-165
authorities and allpersonnel q Surewhie(RAAL90' 56-204-3-165
proper national codes. Signal White IRALsoo3)•• 56-204-4-165
who may be affected by this action Grey White(RAL9002) 56-204-5-165
must be notified. Brown(RAL8028) 56-204-6-165
Black(RAL9005) 56-204-7-165
Absence of a Cover Plate may delay the Brushed Brass 56-204-8-165
sprinkler operation in a fire situation. Brushed Chrome 56-204-9-165
When properly installed,there is an air Custom Paint 56-204-X-165
gap between the lip of the Cover Plate 'Eastern Hemisphere sales only
and the ceiling. The Ordinary Tem- Previously known as Night white
perature Cover Plate assembly has a Note: All Custom Cover Plates are
nominal 1/8 in. (3,2 mm) air gap. The painted using SHERWIN-WILLIAMS
Intermediate Temperature Cover Plate Interior Latex Paint. Contact Johnson
has a nominal 3/32 (2,4 mm) air gap, Controls Customer Service with any
as shown in Figure 2. This air gap is questions related to custom orders.
necessary for proper operation of the
sprinkler by allowing heat flow from a Sprinkler Wrench
Specify:
fire to pass below and above the Cover W-Type 18 Sprinkler Wrench,
Plate to help assure appropriate release P//NN 56-000-1-265
of the Cover Plate in a fire situation. If
the ceiling is to be repainted after the
installation of the Sprinkler, care must
be exercised to ensure that the new
paint does not seal off any of the air .
gap.
TFP442
Page 6 of 6
•
•
•
1400 Pennbroek Parkway,Lansdale,PA 19446I Telephone.1-215-362-0700 ` ,+ F1
C2010 Johnson Controls.All lights reserved All speclncellons and other information shown wore current as of document revision date and are subject to change wlNout nonce. Johnson JJ �I
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of Nstonw Fire Protection Assocreems Controls
TEFLONIs aregbwred lAS WI soerk of DuPont;SNERN.WILLIALIS lamoMIMIC registered modems,*ClaMIMIC LLC
VicoWorldwide
Fire Protection Contacts www.tyco-fire.com
Products
Series TY-FRB, 5.6 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General NOTICE
The TYCO Series TY-FRB Sprinklers "r- `'.•' �--
Descript►on described herein must be installed and
maintained in compliance with this doc- -
The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable ] _ 1
Upright(TY313) and Pendent (TY323) standards of the National Fire Protec- 1
Sprinklers described in this data sheet tion Association,in addition to the Stan- •�' Ai 1 11171
are quick response,standard coverage, dards of any other authorities having .
decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair
sprinklersrd designed for use in lioccupan-
cies nor- the performance of these devices.
ordinary hazard,commercial occupan- _
cies such as banks, hotels,and shop- The owner is responsible for maintain-
ping malls. ing their fire protection system and -
devices in proper operating condition.
The recessed version of the Series TY- The installing contractor or sprinkler
FRB Pendent Sprinkler,where applica- manufacturer should be contacted with
ble, is intended for use in areas with a any questions.
finished ceiling.This recessed pendent
sprinkler uses one of the following: , -., -
S�lrinkler• A two-piece Style 15 Recessed A "`� is-"`
Escutcheon with recessed adjust- Identification
ment up to 5/8 inch (15,9 mm)from 5
the flush pendent position. Number (SIN)
• A two-piece Style 20 Recessed w
Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT
ment up to 1/2 inch (12,7 mm)from TY323 Pendent 5.6K, 1/2"NPT
the flush pendent position. ».
The adjustment provided by the Technical
Recessed Escutcheon reduces the Temperature Rating
accuracy to which the fixed pipe drops Data 135°F(57°C)
to the sprinklers must be cut. 155°F(68°C)
Intermediate level versions of Series Approvals 175°F(79°C)
TY-FRB Sprinklers are described in UL and C-UL Listed 200°F(93 C)
Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved 286 F(141 C)
kler guards and shields are described CE Certified Finishes
in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A
and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated,
tant Sprinklers. Chrome Plated,or Brass Plated
Maximum Working Pressure Physical Characteristics
175 psi(12.1 bar) Frame Bronze
250 psi(17.2 bar)* Button Brass/Copper
'The maximum working pressure of 250 psi Sealing Assembly Stainless
IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON
Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass
Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze
WARNING"that provides cautions K-5.6 GPM/psi112(80,6 LPM/barti2) Deflector Bronze
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and -
installation can permanently dam-
age a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause ,
it to operate prematurely.
Page 1 of 4 FEBRUARY 2014 TFP172
TFP172
Page 2 of 4
•
. Components: *Temperature rating is ** Pipe thread connections per ISO 7-1
1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request.
2 - Button 5 - Compression STYLE 15 or 20
3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED
Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON
6* i C
5 ^I 7/16" `
(11,1 mm) Ill
NOMINAL 2" t IMfc
a II __ I -
' * MAKE-IN (50,8 mm)2WI
7 i� Az 2" 1-3/8'
3 ` y (50,8 mm) ! (34,9 mm) \ '!r
WRENCH
FLATS
1/2"NPT** DEFLECTOR* 2-7/8"(73.0 mm)DIA. —►
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE
G, Operation Installation
The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor,
WRENCH RECESS expands when exposed to heat.When Upright(TY313)and Pendent(TY323)
.........,"., /
(USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor-
END"A') fluid expands sufficiently to shatter the dance with this section.
glass bulb, allowing the sprinkler to General Instructions
FIGURE 2 activate and water to flow. Do not install any bulb-type sprinkler if
W-TYPE 6 the bulb is cracked or there is a loss
SPRINKLER WRENCH Design of liquid from the bulb.With the sprin-
• kler held horizontally, a small air WRENCH bub-
Criteria ble should be present. The diameter
of the air bubble is approximately 1/16
RECESS The TYCO Series TY-FRB,5.6 K-factor, inch(1,6 mm)for the 135°F(57°C)and
Upright(TY313)and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C)
Sprinklers are intended for fire protec- temperature ratings.
s �� tion systems designed in accordance
with the standard installation rules rec-
ognized by the applicable Listing or should be obtained by applying a min-
Approval agency(such as, UL Listing imum to maximum torque of 7 to 14
is based on the requirements of NFPA ft.-lbs.
(9,5 to 19,0 Nm). Higher levels
.."./cp.. • 13, and FM Approval is based on the of torque can distort the sprinkler Inlet
requirements of FM's Loss Prevention with consequent leakage or impairment
PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler.
IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for
ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch-
WITH SPRINKLER
WRENCHING AREA eon Plate by under-or over-tightening
the sprinkler. Re-adjust the position of
FIGURE 3 the sprinkler fitting to suit.
W-TYPE 7 RECESSED
SPRINKLER WRENCH Upright and Pendent Sprinklers
The Series TY-FRB Upright and Pen-
dent Sprinklers must be installed
in accordance with the following
instructions.
Step 1.Install Pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe-thread sealant
. applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
TFP172 •
Page 3 of 4 •
Step 3. Tighten the sprinkler into the 2-7/8"DIA. - •
sprinkler fitting using only the W-Type (73,0 mm)
6 Sprinkler Wrench(Figure 2).With ref-
erence to Figure 1,apply the W-Type 6 2-1/4'DIA. _
Sprinkler Wrench to the wrench flats. FACE OF , (57,2 mm)
Torque sprinklers 7 to 14 ft:lbs.(9,5 to SPRINKLER
19,0 Nm). FITTING -5/8"(15,9 mm)
Recessed Pendent Sprinklers 1 \ - FLUSH
The Series TY-FRB Recessed Pendent 3/8*5/16" ,,,�,�
Sprinklers must be installed in accor- (9,5±7,9 mm) j � 'V
dance with the following instructions. T 7 r
Step A.After installing the Style 15 or MOUNTING/ � • 1/8' J
Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm)
kier threads, and with pipe-thread —
sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8'(34,9 mm)
hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm)
sprinkler fitting. FIGURE 4
Step B. Tighten the sprinkler into the SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323)
sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15
7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON
3).With reference to Figure 1,apply the
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats. Torque 2-7/8"DIA.
sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm)
Nm). FACE OF
IA.
Step C.After ceiling installation and fin- SPRINKLERTNG (57,22-1/2" m)
ishing,slide on the Style 15 or Style 20 FITTING mm)
Closure over the Series TY-FRB Sprin- 5/16±1/4" 12,7 mm 1/2"
kier and push the Closure over the (7,9±6,4 mm) ( )
Mounting Plate until its flange comes in - FLUSH
contact with the ceiling. _"Ii __
Care and } ! — •
MOUNTING OP 1/8" i
Maintenance SURFACE (3,2 mm)
The TYCO Series TY-FRB,5.6 K-factor,
Upright (TY313)and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8'(34,9 mm)
Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm)
viced in accordance with this section. FIGURE 5
Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323)
main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20
work on the fire protection system RECESSED ESCUTCHEON
that it controls, obtain permission to
shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav-
systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing
and notify all personnel who may be corrosive products of combustion,but contractor or sprinkler manufacturer
affected by this action. have not operated,should be replaced regarding any questions.
Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec-
escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested,
a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec-
operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local
The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes.
klers are not used for hanging any after installation. Sprinklers damaged
objects and that the sprinklers are only by dropping,,or striking,likk must wrench
b chre twist/
cleaned by means of gently dusting slid.
P3so replace any sprinkler that has a
with a feather duster;otherwise,non cracked bulb or that has lost liquid from
operation in the event of a fire or inad its bulb.(Ref.Installation Section.)
vertent operation may result.
Sprinklers which are found to be leak- The owner is responsible for the
ing or exhibiting visible signs of corro- inspection,testing,and maintenance of
sion must be replaced. their fire protection system and devices
in compliance with this document, as
Automatic sprinklers must never be well as with the applicable standards
painted, plated, coated, or other- of the National Fire Protection Associa-
wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the
TFP172
Page 4 of 4
P/N* 77 - XXX - X - XXX
I i
SPRINKLER TEMPERATURE
FINISH RATINGS
SIN 1 NATURAL BRASS 135 135'F(57°C)
370 5.6K UPRIGHT(1/2"NPT) TY313 g PURE WHITE(RAL9010)° 155 155°F(68°C)
POLYESTER
371 5.6K PENDENT(1/2"NPT) TY323 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C)
POLYESTER
•Use suffix"I"for ISO 7-1 connection: 9 CHROME PLATED 200 200°F(93°C)
for example,77-370-4-175-1
Eastern Hemisphere sales only
286 286°F(141°C)
TABLE A
SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION
Limited Ordering
Warranty Procedure
For warranty terms and conditions,visit Contact your local distributor for avail-
www.tyco-fire.com. ability.When placing an order, indicate
the full product name and Part Num-
ber(P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify:Series TY-FRB Upright or Pen-
dent(specify)Sprinkler, SIN (specify),
K=5.6, Quick Response,(specify)tem-
perature rating, (specify) finish, P/N
(specify, refer to Table A).
Recessed Escutcheon
Specify:Style 15 Recessed Escutcheon
with(specify*)finish, P/N(specify')
Specify: Style 20 Recessed Escutch-
eon with(specify')finish, P/N(specify*)
*Refer to Technical Data Sheet TFP77D
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 1 Telephone+1-215-362-0700
Copyright®2014 Tyco Fire Products,LP. All rights reserved. NCO
TEFLON is trademark of The DuPont Corporation. Fire Protection Products
N
CPVC ii,z*on ✓ic •
Fig. 188 Two Hole Standoff Strap
Size Range:3/4"through 2"
Finish:Zinc Plated Steel(Hot-Dip Galvanized optional)
Service:Hanger for CPVC pipe in the horizontal position on the bottom of structural wood - .F
beams and steel 20ga.min.(Fig.B).It can also be used as a guide to limit movement for a pipe
in the horizontal/vertical position on the side of structural wood beams,composite wood O
beams and steel 20ga.min.(Fig.A). c �I. us
Approvals:UL and ULC Listed. usmEo
Installation:
• Snap hanger over pipe.
• Position hanger back around pipe but allow for pipe movement. s w,
• Secure hanger to mounting surface with screws provided.Recheck to insure that the pipe
is allowed to move freely through hanger.
• Steel applications require two(2)#14 x 1"hex washer head self-drilling TEK screws.
Not Supplied.Part Number STD-0090.
Features:
• Beveled edge design helps protect the CPVC pipe from any rough surface.
• Easily attaches to wood structure with#10 x 1"hex washer head self threading screw supplied with product.No pre-drilling required.
• Eliminates wooden spacer blocks.
Ordering:Specify CPVC pipe size.figure number and description.
Note:If UL listed restraint is required,use Anvil Fig.188R(Formerly Afcon Fig.514).
A 0C
'�• Ali •• E
•
Fig. A Fig. B
FIG. 188: DIMENSIONS (IN) • WEIGHT(LBS)
CPVC Max. Hanger Approx.
Pipe Size A B eC E F Spacing (FT.) Weight/100 (Ibs)
3/44 16/16 31/4 1/4 1% 23/4 51/2 5
1 1% 33% Y4 14/6 3 6 6
1% 1% 3"/6 3/4 1'/6 35/6 61/2 7
1% 1% 43/6 1/4 13/6 39/16 7 8
2 2 41/2 1/4 1% 41% 8 9
PROJECT INFORMATION APPROVAL STAMP
Project: ['Approved
Address: El Approved as noted
Contractor: ❑Not approved
Engineer: Remarks:
Submittal Date: •
Notes 1:
Notes 2:
PH-1.18
CPVC ,Y .
Fig. 184(Formerly Afcon Fig. 515) Double Offset Hanger and Restrainer
Size Range:3/4"through 1"
Material: Carbon Steel
Finish:Pre-Galvanized per ASTM A653 c0 us
- -
Service: LISTED
• Hanger and surge restraint for horizontal CPVC piping when installed on
the side of the supporting structure.
• Listed with hardware provided on structural wood beams and composite
wood beams(1"minimum).For wood structures with less than 1"thickness,wood
blocks may be placed on the backside of the wood structure.#14x1"fastener pro- Alletafr-1441
tea'
vided must be fully engaged in the wood block.
• May be installed with concrete,steel,and other structural members with fasteners which * •
comply with the requirements of NFPA 13.
Approvals:cULus Listed
Installation:
• Slide CPVC pipe through the double offset hanger and restrainer.
• Secure the hanger to the supporting structure with the screws provided or with listed fasteners.
Features:
• Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion.
• Easily attaches to wood structure with#14 x 1"hex washer head self-threading screw supplied with product.No pre-drilling
required.
• Bottom of pipe is offset 1'/2"from the structure.Eliminates wooden spacer blocks
Ordering:Specify CPVC pipe size,figure number and description.
C x2 0 CPVC Pipe M INE
O
B Structure
L % Fasteners x2
Fig.184
H (�
A 0 MIME
FIG. 184: DIMENSIONS (IN) • WEIGHT(LBS)
CPVC Max. Hanger Approx.
Pipe Size A B uG H L Spacing(FT.) Weight/UM
3/4 1% 1% 1/4 3Yo 5% 5'/2 17
1 11/2 11/2 Y4 3% 5% 6 17
PROJECT INFORMATION APPROVAL STAMP
Project: ❑Approved
Address: ['Approved as noted
Contractor: ❑Not approved
_ Engineer: Remarks:
Submittal Date:
Notes 1:
Notes 2:
PH-1.18
•
Li111111171 FlameGuard®Product
FlameGuard®CPVC Fire Sprinkler Pipe, Fittings,Valves &Solvent Cement
•
FlameGuard® CPVC Fire
Sprinkler Piping Products
•
PRODUCT
Contact Spears® for any Information not found.
Pa e 1 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears"Manufacturing Company
y Effective 02/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing
% IM•,.
FlameGuard®Product
. , = FlameGuard®Overview
• SPEARS®Patented SR Design Sprinkler Head Adapters
s1
'
k,- ' 0
SPEARS® Patented Special Reinforced (SR) plastic female thread design is one of the most
significant advancements in the use of CPVC Fire Sprinkler System threaded fittings. Not just an
41111.1) added ring,this unique precompression design compensates for expansion forces generated from
tapered pipe thread joint make-up.Radial stress is no longer a problem in normal installations and
easily managed in severe over-tightening situations.
. "O./
Contains and Compensates for Radial Stress...
Radial stress, generated by tightening of tapered pipe threads,exerts tremendous expansion force on female plastic thread fittings.When subjected to
over-tightening -even accidentally-these forces can literally split the fitting. Spears® patented SR Adapter design not only alleviates this problem by
containing expansion forces with its special reinforced collar, but additionally compensates for expansion stress through thermoplastic material
compression. Stresses are equalized at normal joint make-up. The following graph illustrates this effect in a comparison of conventional plastic female
thread fittings with Spears®SR adapters when taken to failure.
1
EXPANSION SPLIT FITTING STRIP THREADS
FORCES CONVENTIONAL ,
PLASTIC THREAD '
FITTINGS
0
..emaillri"......1 ADDITIONAL
I TURNS TIGHT
SPEARS' SR '
COMPRESSION PLASTIC THREAD ,
FORCES FITTINGS ,
NORMAL JOINT
MAKE-UP
Another Quality SPEARS Product Designed for Performance, Customer Satisfaction and Service.
Mede in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas page 2
Effective 02/01/2020 See MSRP-1 Sheet or Check Spears°On-line Catalog®www.spearsmfg.com for Pricing
i
FlameGuard®Product - -
SPES FlameGuard®CPVC Fire Sprinkler Piping Products
Part Number Size Std Mstr Prod MSRP
FlameGuard®CPVC Fire Sprinkler Piping Products Pk Ctn code
Part Number Size Std Matr Prod MSRP
Pk Ctn Code
Pipe-FlameGuard®CPVC Fire Sprinkler Plain End Reducing Tee44
SDR 13.5 10' Lengths 11110.111111111.51.
Socket x Socket x Socket
Price Per Foot 4201-102 3/4X1 20 0 070 7.53
CP-007-10 3/4 1260 0 071 2.10 4201-125 1X314X3/4 15 150 070 7.53
CP-010-10 1 170 0 071 3.25 4201-126 1X3/4X1 15 0 070 7.53
CP-012-10 1-1/4 90 0 071 5.08 4201-131 1X3/4 20 0 070 7.53
CP-015-10 1-1/2 70 0 071 7.02 4201-157 1-114X1X3/4 15 0 070 13.88
CP-020-10 2 50 0 071 10.49 4201-158 1-1/4X1X1 15 0 070 13.88
CP-025-10 2-1/2 40 0 . 071 : 16.02 4201-159 1-1/4X1X1-1/4 15 0 070 13.88
CP-030-10 3 30 0 071 24.34' 4201-167 1-1/4X3/4 15 0 070 13.88
14201-168 1-1/4X1 15 0 070 13.88
Pipe-FlameGuard®CPVC Fire Sprinkler Plain End 4201-169 1-1/4X1-1/2 10 0 070 16.77
SDR 13.5, 15'Lengths 4201-201 1.1/2x1.1/4x3/4 10 0 070 16.77
4201-202 1-1/2X1-1/4X1 10 0 070 16.77
Price Per Foot 4201-210 1-1/2X3/4 15 0 070 16.77
CP-007 3/4 1390 0 071 2.10 4201-211 1-1/2X1 10 0 070 16.77
CP-010 1 255 0 0711 3.25 4201-212 1-112X1-1/4 10 0 070 16.77
CP-012 1-1/4 135 0 071 5.08
4201-213 1-1/2X2 10 0 070 26.60
CP-015 1-1/2 105 0 071 7.02; 14201-248 2X3/4 10 0 070 26.60
CP-020 2 75 0 071 10.49 4201-249 2X1 10 0 070 26.60
CP-025 2-1/2 60 •0 1 16.02 4201-250 2X1-1/4 10 0 070 26.60 -
LP-030 3 45 0 071 1 24.34 4201-251 2X1-1/2 10 0 070 26.60 -
4201-289 2-1/2X1 10 0 070 36.58
4201-290 2-1/2X1-1/4 10 0 070 36.58 '
Tee 41116
4201-291 2-1/2X1.1/2 10 0 070 36.58
4201-292 2-1/2X2 10 0 070 36.58
Socket x Socket x Socket 4201-335 3X1 5 0 070 42.22
4201-007 3/4 120I220 070 4.40 4201-3361 3X1-1/4 5 0 070 42.22
4201-337 3X1-1/2 5 0 070 42.22
4201-010 1 15 : 120 070 8.91 4201-338 3X2 5 0 070 42.22
4201-012 1-1/4 10 0 070 13.31 4201-339 3X2-112 6 0 070 42.22
4201-015 1-1/2 10 0 070 19.58
4201-020 2 10 i 0 070 28.91 1 Outlet sized with Bushing
4201 025 2-1/2 10 0 070 47.09 GripLocuA Extension Tee
4201 030 3 5 0 070 73.80 Socket x Socket x GripLocTM
WARNING: DO NOT INSERT FINGERS
GripLocT"' Tee EPDM Gasket
WARNING: DO NOT INSERT FINGERS Uses No Solvent Cement-NSFe Certified Lead Free
EPDM Gasket 175 psi (1.21 Mpa)a 150° F(66°C)
Uses No Solvent Cement-NSFe Certified Lead Free GLs4201-010 1 1 15 134 24.93
175 psi (1.21 Mpa)@ 150° F(66°C)
GL4201-007 ll 3/4 15 0 134 41.6s SofTorque n4 SR Sprinkler Head Tee-Gasket
4
GL42D1-010 1 1 ; 15 134 47.32
Sealed Special Reinforced Plastic Thread Style
Socket x SR Fipt-Stainless Steel Collar With
Elastomer Seal-Use NO Thread Sealant
NSFe Certified Lead Free
4202-101GSR 314X1/2 50 0 076 16.29
4202-1240SR 1X3/4X1/2 50 0 076 17.60 -
4202-130GSR 1X1/2 20 0 076 17.60
Page 3 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears°Manufaclunng Company
Effective 02/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalog Q www.spearsmfg.com for Pricing
FlameGuard®Product
)FlameGuard®CPVC Fire Sprinkler Piping Products ]
it
® Part Number Size Std Mstr Prod MSRP
FlameGuard CPVC Fire Sprinkler Piping Products Pk Ctn Code
Part Number Size Std Mstr Prod MSRP SofTorquet'SR Sprinkler Head Tee-Gasket
Pk Ctn Code
Sealed Special Reinforced Plastic Thread Style
TorqueSafeTM Sprinkler Head Tee-Gasket Sealed Socket x SR Fipt x Socket-Stainless Steel
Brass Thread Insert Style Collar With Elastomer Seal -Use NO Thread
Sealant
Socket x Socket x Gasket Fipt With Elastomer NSFe Certified Lead Free
Seal -Use NO Thread Sealant
4203-122GSF1 1X1/2X1 L501_0 j 076 , 17.60
4202-101 G 3/4X112 50 0 076 16.29
4202-124 G 1X3/4X1/2 50 0 076 17.60 TorqueSafeTM Sprinkler Head Tee-Gasket Sealed 4
4202-130 G 1X1/2 50 0 076 17.60 Brass Thread Insert Style
4202-131 G 1X314 50 0 076 19.06 Socket x Gasket Fipt x Socket With Elastomer
4202-166 G 1-114X1/2 15 0 076 29.34 Seal -Use NO Thread Sealant
4202-209 G 1-112X1/2 10 0 076 38.65 4203-122 G 1X1/2X1 50 0 076 1 28.91
4202-247 G 2X1/2 10 0 076 54.51
FIPT With Elastomer Seal-Use NO Thread Sealant
FIPT With Elastomer Seal-Use NO Thread Sealant.
Not intended to convey or dispense water for human consumption
Not intended to convey or dispense water for human consumption through drinkint�or cooking
through drinking or cooking
Sprinkler Head Tee Brass Thread Insert Style Sprinkler Head Tee-Brass Thread Insert Style
Socket x Socket x Fipt Socket x Fipt x Socket * ""#
4202-101 3l4X7/2 50 0 076 16.29 4203-122 1X1/2X1 1 50 0 076 1 28.91
4202-124 1X3/4X1l2 50 0 076 17.60 Not intended to convey or dispense water for human consumption
__. through drinking or cooking
4202-130 1X112 50 ' 0 076 17.60
4202-010 1 10 40 076 45.25 Sprinkler Head Tee-Special Reinforced Plastic l
4202-156 1-1/4X1X1/2 15 0 076 29.34 Thread Style
• 4202-166 1-114X1/2 15 0 076 29.34 Socket x SR Fipt x Socket-Stainless Steel 4`
4202-199 1-112X1.1/4X1f2 10 0 076 38.65 Collar
4202-209 1-1/2X1/2 10 0 076 38.65 NSFe Certified Lead Free
4202-237 2X1-1/2X112 10 0 076 54.51 4203-1223R 1X1/2X1 50 0 076 ; 10.07
4202-247 2X1/2 10 0 076 54.51
Not intended to convey or dispense water for human consumption
through drinking or cooking
Street Tee40
Sprinkler Head Tee-Special Reinforced Plastic
Thread Style Spigot x Socket x Socket
Socket x Socket x SR Fipt-Stainless Steel 4244-007 3/4 15 105 070 `' 7.83
Collar 4244-010 1 15 0 070 I 10.46
NSF®Certified Lead-Free 4244-012 1-1/4 10 0 070 19.00
4202-010SR 1 15 0 076 24.04 4244-015 1-1/2 10 0 070 23.00
4202-101SR 3/4X1/2 50 0 076 8.67 4244-020 2 10 0 070 33.99
4202-124SR 1X314X112 50 0 076 9.38
4202-130SR 1X1/2 50 0 076 9.38
4202-131SR 1X3/4 15 0 076 19.06 90' Ell1110
4202-156SR 1-114X1X1/2 15 0 076 15.62 Socket x Socket
4202-166SR 1-1/4X1/2 15 0 076 15.62
4202-168SR 1-1/4X1 15 0 076 33.57 4206-007 3/4 30 300 070 3.24
4202-199SR 1.1/2X1-1/4X1/2 10 0 076 20.56 4206-010 1 20 200 070 7.20
4202-209SR 1-1/2X112 25 0 076 20.56 4206-012 1-1/4 10 100 070 9.20
4202-211SR 1-1/2X1-1/2X1 10 0 076 20.56 4206-015 1-1/2 10 0 070 12.84
4202-237SR 2X1-1/2X1/2 10 0 076_ 29.01 4206-020 2 25 0 070 i 15.87
' 4202-247SR 2X1/2 10 0 076 29.01 4206-025 2-1/2 5 0 1 070 30.65
4202-287SR 2-112X1/2 10 0 076 39.76 4206-030 3 5 0 070 41.80
Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 4
Effective 02/01/2020 See MSRP-1 Sheet or Check Spears°On-line Catalog @ www.spearsmfg.com for Pricing
FlameGuard®Product
MIS
FlameGuard®CPVC Fire Sprinkler Piping Products
w it •) _
FlameGuard®CPVC Fire Sprinkler Piping Products Part Number Size Std Mstr Prod MSRP
P P 9 Pk Ctn Code
Part Number Size Std Mstr Prod MSRP Sprinkler Head 90° Ell -Brass Thread Insert Style(continued)
Pk Ctn Code Socket x Fipt
4207-131 1X314 25 0 076 18.32
90°Ell-Sweep 4207-166 1-1/4X1/2 - 10 60 076 21.07
Not intended to convey or dispense water for human consumption
Socket x Socket through drinking or cooking
4206-010S 1 30 0 070 13.31 Sprinkler Head 90° Ell -Special Reinforced Plastic
GripLoc' 90° ElI Thread Style
"t
Socket x SR Fipt-Stainless Steel Coillar
WARNING: DO NOT INSERT FINGERS NSFe Certified Lead-Free
EPDM Gasket 4207-101SR 314X1/2 20 180 076 5.72
Uses No Solvent Cement-NSFe Certified Lead Free 4207-130SR 1X1/2 10 150 076 8.06
175 psi(1.21 Mpa)f 150° F(66°C) 4207-131SR 1X314 50 0 076 9.75
GL4206-007 3/4 20 0 134 26.38 4207-166SR 1-1/4X112 25 0 076 10.24
GL4206-010 1 1 20 134 30.14
90°Street Ell
90°Reducing Eli
Spigot x Socket
Socket x Socket
4209-007 3/4 50 0 070 7.03
4206-131 1X314 20 240 070 6.38 4209-010 1 50 0 070 10.39
14206-168 1-1/4X1 15 0 070 27.09 4209-012 1-1/4 25 0 070 17.11 -
SofTorqueTMl SR 90°Sprinkler Head Elbow- 4209-015 1-1/2 10 0 070 20.83
Gasket Sealed Special Reinforced Plastic Thread 4209-020 2 25 0 070 30.67
Style
Socket x SR Fipt-Stainless Steel Collar With Side Outlet Ell
a .
Elastomer Seal -Use NO Thread Sealant
NSF,Certified Lead-Free Socket x Socket x Socket
4207-101GSR 3/4X1/2 20 140 076 5.72
4207-130GSR 1X1/2 20 80 076 8.06 4213-007 3/4 50 0 070 10.55
4207-166GSR 1-114X112 15 60 076 10.24 4213-010 1 25 0 070 14.38
TorqueSafeTM 90°Sprinkler Head Elbow-Gasket
Sealed Brass Thread Insert Style 22-1/2°Ell
Socket x Gasket Fipt With Elastomer Seal-Use Socket x Socket
NO Thread Sealant !lib
4207-101 G 3/4X112 20 120 076 10.77 4216-007 3/4 ' 20 360 070 5.25
4207-130 G 1X1/2 15 90 076 15.14 4216-010 1 20 240 070 6.79
4207-166 G 1-1/4X112 10 60 076 21.07 4216-012 1-1/4 20 0 070 9.19
FIPT With Elastomer Seal-Use NO Thread Sealant. 4216-015 1-1/2 20 0 070 12.62
Not intended to convey or dispense water for human consumption 4216-020 2 20 0 070 15.62
through drinking or cooking 4216-025 2-1/2 5 0 070 32.08
16 4216-030 3 5 0 070 ' 40.67
Sprinkler Head 90° ElI-Brass Thread Insert Style
Socket x Fipt 22-1/2°Street ElI
4111110
4207-101 314X112 20 120 076 ' 10.77 Spigot x Socket
4207-130 1X112 15 90 076 15.14 4242-007 314 50 0 070 5.52 •
4242-010 1 50 0 070 7.11 -
4242-012 1-1/4 20 0 070 9.66 -
4242-015 1-1/2 25 0 070 13.26
Page 5 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears"Manufacturing Company
Effective 0 2101/2 0 2 0 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing
ton
FlameGuard®Product
. ) US
• 1 FlameGuard®CPVC Fire Sprinkler Piping Products
Std Mstr Prod
FlameGuard®CPVC Fire Sprinkler Piping Products Part Number Size Pk Ctn Code MSRP
Part Number Size Std Mstr Prod MSRP
Pk Ctn Code
22-1/2°Street Ell(continued) Couplinga*
Spigot x Socket
4242-020 2 20 0 070 16.42 Socket x Socket
4242-025 2-1/2 5 0 070 23.02 4229-007 3/4 ( 25 1500 070 i 3.16
4242-030 3 5 0 070 32.98 4229-010 1 25 250 070 '', 4.04
lb 4229-012 1-1/4 10 1 160 070 6.07
45° Ell 4229-015 1-1/2 10 100 070 1 8.66
4229-020 2 20 0 070 1 11.67
Socket x Socket 4229-025 2-1/2 10 0 070 17.78
4229-030 3 5 0 070 23.14
4217-007 3/4 20 360 070 4.40
4217-010 1 15 240 070 5.22
4217-012 1-114 10 120 070 7.64
4217-015 1-1/2 10 0 070 10.53 Reducer Coupling '
4217-020 2 10 0 070 13.24
4217-025 2-1/2 5 0 070 i 23.59 Socket x Socket
4217-030 3 5 0 070 34.12
4229-131 1X3/4 15 270 070 4.04!
45°Street Ell 4229-167 1-1/4X3/4 25 0 070 6.281
4229-168 1-114X1 _ 10 140 070 6.07�:
Spigot x Socket 4229-210 1-1/2X3/4 125 0 070 9 36i
4229-211 1-1/2X1 10 70 070 9.09j
4227-010 1 504 0 070 5.22 4229-212 1-1/2X1-1/4 10 1201_070 8.661
4227-012 1-1/4 25 0 070 1 7.64 4229-248 2X314 k 10 80 070 12.20!
4227-015 1-1/2 25 0 070 1 9.46 4229-249 2X1 25 0 r 070 12.201
4227-020 2 20 0 070 4229-250 2X1-1/4 10 60 070 11.88
13.24 4229-251 2X1-1/2 10 100 070 11.67'
4229-291 2-1/2X1-1/2 1 10 0 070 17 97
Cross 4229-292 2-1/2X2 10 0 f 070 18.43
4229-339 3X2-1/2 1 10 0 070 54.72 4229-337 3X1-1/2 5 0 070
Socket x Socket x Socket x Socket i 54.72)
4220-007 3/4 20 0 070 6.94
4220-010 1 15 0 070 8.66 GripLocMI Coupling
4220-012 1-1/4 10 0 070 12.06 WARNING: DO NOT INSERT FINGERS
4220-015 1-1/2 10 0 070 16.47 EPDM Gasket
4220-020 2 8 0 070 26.83
4220-025 2-1/2 5 0 070 58.98 Uses No Solvent Cement-NSF®Certified Lead Free
4220-030 3 5 0 070 86.51 175 psi (1.21 Mpa) 150°F(66°C)
GL4229-007 3/4 11 1 36 ! 134 26.32
GL4229-010 1 1 20 134 28.25
Reducing Cross GL4229-020 2 C 1 10 134 30.03
Socket x Socket x Socket x Socket
4220-131 1X3/4 20 0 070 9.36 Grooved Coupling Adapter
4220-167 1-1/4X3/4 25 0 070 14.45 Groove x Socket
4220-210 1-1/2X314 15 0 070 20.17
4220-248 2X3/4 10 0 070 26.46 4233-012 1-1/4 10 40 076 121.57
4220-289 2-1/2X1 15 0 070 37.31 4233-015 1-112 10 40 076 128.851
4233-020 2 8 32 076 149.231
4233-025 2-1/2 5 0 ' 076 191.42]
- 4233-030 3 5 0 I076 J 212.80
Not intended to convey or dispense water for human consumption
through drinking or cooking
•
Made in the U SA. Suitable for Oil-Free air handling to 25 psi.not for distribution of compressed air or gas Page 6
Effective 02/01/2020 See MSRP-1 Sheet or Check Spears On-line Catalog @ www.spearsmfg.com for Pricing
FlameGuard®Product
SPURSFlameGuard®CPVC Fire Sprinkler Piping Products
FlameGuard®CPVC Fire Sprinkler Piping Products Part Number Size Std Mstr Prod MSRP
Pk Ctn Code
Part Number Size Std Mstr Prod MSRP Female Adapter-Brass Thread Insert Style(continued)
Pk Ctn Code Socket x Fipt
QuickTorqueTM SR Female Sprinkler Head Adapter 4235-015 1-1/2 10 40 076 82.01
-Gasket Sealed Special Reinforced Metal Thread 4235-020 2 8 32 076 102.78
Style Not intended to convey or dispense water for human consumption
Socket x SR Fipt-Stainless Steel Collar With through drinking or cooking
Elastomer Seal -Use NO Thread Sealant
NSF®Certified Lead Free Female Sprinkler Head Adapter-Brass Thread
4235-1o1GMR 3/4X1/2 50 0 076 11.46 Insert Style
4235-130GMR 1X1/2 50 0 076 12.75
SofTorqueTM" SR Female Sprinkler Head Adapter- Socket x Fipt
Gasket Sealed Special Reinforced Plastic Thread 4235-101 3/4X1/2 50 0 076 : 13.00
Style 4235-130 1X1/2 50 0 076 13.74
Socket x SR Fipt-Stainless Steel Collar With 4235-131 1X3/4 50 0 076 19.80
Elastomer Seal -Use NO Thread Sealant Not intended to convey or dispense water for human consumption
NSF®Certified Lead-Free through drinking or cooking
4235-101GSR 314X1/2 50 0 076 11.46
4235-13OGSR 1 1X1/2 50 0 076 12.21 Female Sprinkler Head Adapter-Special
TorqueSafeTM Female Sprinkler Head Adapter- Reinforced Plastic Thread Style
Gasket Sealed Brass Thread Insert Style Socket x SR Fipt-Stainless Steel Collar
Socket x Gasket Fipt With Elastomer Seal -Use NSF®Certified Lead-Free
NO Thread Sealant 4235-101SR 3/4X1/2 50 200 076 6.23
4235-101 G 3/4X1/2 50 0 076 14.01 4235-130SR 1X1/2 50 0 076 6.66 -
4235-130GS 1X1/2 50 0 076 14.86 4235-131SR 1X3l4 50 0 076 10.55
4235-131 G 1X3/4 50 0 076 21.36 Female Sprinkler Head Adapter-Special *•e. •
FIPT With Elastomer Seal-Use NO Thread Sealant. Reinforced Plastic Thread Style with Socket Body Not intended to convey or dispense water for human consumption y
through drinking or cooking Wrench Flats kr(
GripLocTM TorqueSafeTM' Female Sprinkler Head Socket x SR Fipt-Stainless Steel Collar
Adapter-Gasket Sealed Brass Thread Insert Style NSF®Certified Lead-Free
p Y IW4235-101SR L 3/4X7l2 50 0 076 7.11
WARNING: DO NOT INSERT FINGERS W4235-130SR 1X1/2 50 0 076 7.60
EPDM Gasket
Uses No Solvent Cement or Thread Sealant
GL4235-101 G 3/4X112 25 0 134 23.58 Female Sprinkler Head Adapter-Brass Thread
IGL4235-130G 1X112 24 0 134 26.29 Insert Style with Long Body
FIPT With Elastomer Seal-Use NO Thread Sealant Socket x Fipt
Not intended to convey of c,isnense water for human consumption L4235-130 1X112 50 I 0 I 076 17.76
through drinking or cooking Uses No Solvent Cement
175 si 1.21 Mpa)t 150°F(66•C) Not intended to convey or dispense water for human consumption
through drinking or cooking
Female Adapter-Brass Thread Insert Style f Female Sprinkler Head Adapter-Brass Thread
Socket x Fipt Insert Style with Positioning Ring
4235-007 3/4 15 90 f 076 21.48
Socket x Fipt
4235-010 1 15 90 076 37.71 1 R4235-101 314X112 50 0 076 11.75
4235-012 1-1/4 15 60 i 076 61.47 Not intended to convey or dispense water for human consumption
—- through drinking or cooking
Female Sprinkler Head Adapter-Special
Reinforced Plastic Thread Style with Positioning "
Ring
i Socket x SR Fipt-Stainless Steel Collar
R4235-101SR j 3/4X112 251300 076 7.03 "
Suitable for OII-Free air handlingto 25psi,not for distribution of compressed air or gas Spears Manufacturing Company
Page p
Effective 02rDV202D See MSRP-1 Sheet or Check Spears®On-line Catalog r.�www.spearsmfg.com for Pricing
As
FlameGuard®Product
11
FlameGuard®CPVC Fire Sprinkler Piping Products � ��
Std Mstr Prod
FlameGuard® CPVC Fire Sprinkler Piping Products Part Number Size Pk Ctn Code MSRP!
Part Number Size Std Mstr Prod MSRP Bushing-with Brass Thread Insert(continued)
Pk Ctn Code Spigot x Fipt
Not intended to convey or dispense water for human consumption
Female Adapter-Special Reinforced Plastic through drinking or cooking
Thread Style
Socket x SR Fipt-Stainless Steel Collar Spigot Female Sprinkler Head Adapters-Brass
NSF®Certified Lead-Free Thread Insert Style I,
4235-007SR 3/4 25 300 076 ' 10.19 Spigot x Fipt
4235-010SR 1 25 200 076 17.93 4238-101 314X112 50 200 076 7 11.75'
4235-012SR 1-1/4 10 60 076 29.19 4238-130 1X112 50 0 076 ; 12.54
Not intended to convey or dispense water for human consumption
Aiip through drinking or cooking
Transition Male Adapter with Brass Thread SofTorqueTM Spigot Female Adapter-Gasket
Mipt x Socket Sealed Special Reinforced Plastic Thread Style
NSF®Certified Lead-Free Spigot x SR Fipt-Stainless Steel Collar With
4236-007 3/4 40 160 076 48.36 Elastomer Seal - Use NO Thread Sealant
4236-010 1 10 60 076 73.93 NSF®Certified Lead Free
4236-012 1-1/4 10 40 076 88.41 4278-101GSR 3/4X112 50 0 076 10.71
4236-015 1-1/2 10 40 076 160.45 4278-130GSR 1X1/2 50 0 7 076 19.06
4236-020 2 8 32 076 213.52
TorqueSafeN Female Spigot Sprinkler Head Spigot Female Adapter-Brass Thread Insert Style -_
- Adapters-Gasket Sealed Brass Thread Insert
Style . ...... . .. . .... ... ...
Spigot x Gasket Fipt With Elastomer Seal- Use
• NO Thread Sealant
4278-007 20.0t �_____
4238-101 G 3l4X1/2 50 200 076 11.75 4278-010 1 15 90 1 076 1 35.80
4238-130 G 1X1/2 50 0 1 076 12.54 Not intended to convey or dispense water for human consumption
through drinking or cooking
FIPT With Elastomer Seal-Use NO Thread Sealant.
Not intended to convey or dispense water for human consumption
through drinking or cooking Spigot Female Adapter-Special Reinforced Plastic
SofTorqueTM Reducer Bushing-Gasket Sealed Thread Style It f
Plastic Thread Style Spigot x SR Fipt -Stainless Steel Collar
Spigot x Fipt-With Elastomer Seal -Use NO NSF®Certified Lead-Free
Thread Sealant 4278-007SR 3/4 25 300 076 1 10.71
4238-130GSR 1X1/2 50 300 076 14.16 4278-010SR 1 50 0 076 L 19_06
TorqueSafeTM Bushing-Gasket Sealed Brass
Thread Insert Style Replacement Gaskets for all TorqueSafeN Gasket
Spigot x Gasket Fipt With Elastomer Seal-Use Sealed Head Adapters
NO Thread Sealant Pack of 25 EPDM Gaskets
423e-130BR G I 1X1/2 50 200 076 16.221 For Use in 1/2"or 3/4"Gasket Sealed Threads
FIPT With Elastomer Seal-Use NO Thread Sealant. 1 RGSK-005 ; 1/2 1 1 1 100 299 13.04
Not intended to convey or dispense water for human consumption !RGSK-007 _i_ 3/4 11 1100T299 18.22�
through drinking or cooking
Spigot Female Sprinkler Head Adapters-Special
Bushing -with Brass Thread Insert Reinforced Plastic Thread Style
Spigot x Fipt Spigot x SR Fipt-Stainless Steel Collar
• NSF®Certified Lead-Free
L4238-130BR 1X1/2 50 200 076 16.22 4238-101SR 3/4X1/2 50 400 076 6.23I
4238-130SR j 1X1/2 50± 0 076 L 6.75
Made in the U.S A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 8
Effective 0 2/0112 02 0 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing
11!::Iir FlameGuard®Product •
FlameGuard®CPVC Fire Sprinkler Piping Products
FlameGuard®CPVC Fire Sprinkler Piping Products Std Mstr Prod
Part Number Size Pk Ctn Code MSRP
Part Number Size L-Max Std Mstr Prod MSRP
l Pk Ctn Code
Transition Bushing
Adjustable Sprinkler Head Adapters- IPS Spigot x CTS Socket
Special Reinforced Plastic Thread Style 4240-101 3/4X1/2 50 300 070 11.09
4240-130 1X1/2 50 300 070 8.73
Socket x SR Fipt-Stainless Steel Collar
TRAVEL= 1-9/16"
Cap
NSF®Certified Lead-Free Socket
420015R 3/4X1/2 8-1/4 12 0 076 15.91
42011SR 1X1/2 8-3/8 12 0 076 15.91 4247-007 3/4 25 400 070 1.91
L-Max=Maximum Adjustable Length 4247-010 1 25 450 070 2.76
4247-012 1-1/4 10 60 070 4.34
4247-015 1-1/2 10 160 070 6.03
Adjustable Sprinkler Head Adapters- 4247-020 2 10 1 60 070 9.18
Special Reinforced Plastic Thread Style 4247-025 2-1/2 5 40 070 13.01
4247-030 3 5 0 070 21.28
Spigot x SR Fipt-Stainless Steel Collar
TRAVEL= 1-5/8" GripLocTM Cap
WARNING: DO NOT INSERT FINGERS .
NSF®Certified Lead-Free EPDM Gasket
42004SR 3/4X1/2 8-1/4 12 0 076 15.91 -
42014SR 1X1/2 8-1/4 12 0 076 15.91 Uses No Solvent Cement-NSF®Certified Lead Free
L-Max=Maximum Adjustable Len, 175 psi(1.21 Mpa) 150°F(66°C)
G L 424 7-00 7 3/4 1 25 134 23.44
Part Number Size Std Mstr Prod MSRP GL4247-010 1 1 50 134 25.17
Pk Ctn Code
Test Plug-0-ring Sealed
Reducer Bushing -Flush Style Mipt-For Pressure Testing Only. NOT for use
with TorqueSafeTM or Z4235 Series Adapters
Spigot x Socket
FTP-005 1/2 50 400 079 1.97
4237-131 1 X3/4 50 700 070 2.45 DO NOT use with Tape or Paste thread sealants
4237-167 1-1/4X3/4 251200 070 3.85
4237-168- 1-114X1 25 i 350 070 3.85
4237-210 1-1/2X314 25 i 125 070 4.34 Test Plug Replacement 0-ring
4237-211 1-1/2X1 25 150 070 4.34
i Buna-N, For 0-ring Sealed Test Plug Only
4237-212 1-112X1-1/4 25 300 070 4.34
4237-248 2X3/4 10 150 070 6.36 Pack of 100
4237-249 2X1 10 160 070 6.36 BPB-116 116 1 10 I 891 4.37
4237-250 2X1-1/4 10 160 070 6.36 For Use With FTP-005 Test Plug
4237-251 2X1-1/2 10 160 070 6.36
4237-290 2-1/2X1-1/4 10 40 070 11.01 Test Plug for TorqueSafeTM &SofTorqu&"Gasket
4237-291 2-1/2X1-1/2 10 40 070 11.01 Sealed Head Adapters
4237-292 2-1/2X2 15 0 070 11.01 Mipt- For Pressure Testing Only. Use ONLY with
4237-338 3X2 10 0 070 18.47 Gasket Sealed Adapters
4237-339 3X2-1/2 10 0 070 16.47 FTP-005GS 1/2 50 400 004 1.97
Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears®Manufacturing Company -
Page 9 Effective 02/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalogwww.s earsmf .com for Pricing
Pe @ P 9
e ,rin 1
FlameGuard®Product
FlameGuard®CPVC Fire Sprinkler Piping Products ]
I
Std Mstr Prod
FlameGuard®CPVC Fire Sprinkler Piping Products Part Number Size Pk Ctn Code MSRP
Part Number Size Std Mstr Prod MSRP
Pk Ctn Code
Union
Test Plug-White PVC
Mipt- For Pressure Testing Only Socket x Socket
4250-005 1/2 50 400 070 2.07 175 psi (1.21 Mpa)0 150° F(66°C)
Requires use of a thread sealant 4257-007 3/4 i 10 80 070 8.80'
4257-010 1 ! 10 40 070 15.95
Flange-One Piece 4257-012 1-1/4 I 5 20 070 20.87
4257-015 1-1/2 I 5 0 070 24.75:
Socket-4 Bolt Holes -175 psi (1.21 Mpa)@ 150° 4257-020 2 5 0 070 40.65
F (66°C)
•
4251-007 3/4 25 0 070 6.82
4251-010 1 15 0 070 9.06 Transition Union-Metal Thread Insert Style
4251-012 1-114 15 0 070 11.67
4251-015 1-112 15 0 070 13.53 Socket x Fipt
4251-020 2 10 0 070 20.68
4251-025 2-112 10 0 070 35.00
175 psi(1.21 Mpa)@ 150° F(66°C)
4259-010BR 1 10 0 076 55.41
Blind Flange 4259-012BR 1-1/4 5 20 076 81.25t
4259-015BR 1-1/2 5 0 076 115.45
4 Bolt Holes -175 psi (1.211 Mpa) @ 150° F(66°C) 4259-020BR 2 5 j 0 076 ; 170.26
Not intended to convey or dispense water for human consumption'
4253-007 3/4 25 0 070 6.82 through drinking or cooking
• 4253-010 1 15 0 070 9.71
4253-012 1-1/4 15 0 070 12.40 Std Mstr Prod
4253-015 1-1/2 15 0 070 13.93 Part Number Size Travel T Pk Ctn Code MSRP
4253-020 2 10 0 070 22.81
4253-025 2-1/2 10 0 070 36.67
4253-030 3 10 0 070 40.27
Short Repair Couplings
Flange-Van Stone Style
Spigot x Socket
Socket-4 Bolt Holes-175 psi (1.21 Mpa)@
150° F(66°C)
175 psi(1.21 Mpa)@ 150°F(66°C)
4254-030 3 10 0 070 43.01 SH118-07C0 3/4 2 30 0 078 15.81
SH118-1000 1 2-1/8 35 0 078 25.64
Unit Must Be Thrust Blocked
Flange-Van Stone Style T=Repair Coupling Travel
Spigot-4 Bolt Holes -1755 psi (1.21 Mpa)@
150° F(66°C) GripLocm Repair Coupling
4256-007 3/4 25 0 070 ! 7.03 i WARNING: DO NOT INSERT FINGERS
4256-010 1 15 0 070 9.93 EPDM Gasket
4256-012 1-1/4 15 0 070 12.69
4256-015 1-1/2 15 0 070 14.25
• 4256-020 2 10 0 070 23.24 Uses No Solvent Cement-NSFe Certified Lead Free
4256-025 2-1/2 10 I 0 070 37.18 175 psi (1.21 Mpa)@ 150°F(66°C) _
• 4256-030 3 10 0 070 43.38 SG118-07C0 3/4 2-15/16 1 25 134 44.04
SG 118-1000 1 2-7/8 1.1 25 1 134 49.86
Made in the U.S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas 1 tip
Effective 02/01/2020 See MSRP-1 Sheet or Check Spears On-line Catalog g www.spearsmfg.com for Pricing PageV
v
FlameGuard®Product "
SE ( , .
FlameGuard®CPVC Fire Sprinkler Piping Products
FlameGuard® CPVC Fire Sprinkler Piping Products Std Mstr Prod
Part Number Size Pk Ctn Code MSRP
Part Number Size Travel-T Std Mstr Prod MSRP1
Pk Ctn Code
GripLocTM Repair Coupling (continued) Roller-Small Cap
WARNING: DO NOT INSERT FINGERS
EPDM Gasket Fits 1-3/4" Neck Quart Cans(MT-651).
Unit Must Be Thrust Blocked Replaceable cover. For pipe size 3"to 6".
T=Repair Coupling Travel
Std Mstr Prod 6020 4"length 24 0 710 16.55
Part Number Size MSRP
Pk Ctn Code
Roller Replacement Covers
Fits Rollers with Heavy Handles #5520,
#6020 ᥸. Sold as Pack of 2,full pack
only.
Blue 75TM Thread Sealant 5520-1 Fits 5520&6020 Roller 1 75 710 14.99
ISB75-005 1/4 Pint 24 T 0 ! 895 12.20
SB75-010 1/2 Pint 24 0 895 19.43
tSB75-020 Pint 12 0 895 31.42
SB75-030 Quart 12 0 895 56.46
Cap Dauber
DP-75 3/4"for Pint 50 0 710 1.45
DP-125 I 1-1/4"for Pint 50 0 - 710 1.75
DQ-125 1-114"for Quart 50 0 710 1.75 "
FS-5 One Ste Cement *3/4"Diameter fits Pint Cans,for pipe size 3/4"
.__.. --1-1/2"Diameter fits Pint Cans,for pipe size 1-1/2"
r S5-020 ., Pint 12 0 703 31.31 --*1-1/2"Diameter fits Quart Cans,for pipe size 1-1/2"
FS5-030 _ Quart , 12 0 703 57.43
Can-Mate Dauber
Adjustable Plastic Applicator with
Empty Cans Telescoping Stem for use with Standard
Pint and Quart Cans.
With Cap/Lid -order Daubers separately
CM-75 3/4" 50 0 710 5.83
MT-654 Pint 12 0 {7{ 10 6.09 CM-150 1-1/4" 50 0 710 5.83
MT-651 Quart 12 0 1710 7.92 3/4"Diameter tits Pint or Quart Cans,for pipe sizes 3/4"-1-1/4"
MT-653 Quart 12 0 1710 9.26 1-1/4"Diameter fits Pint or Quart Cans,for pipe sizes 1-1/2"-3"
1 1-3/4 Screw Neck
2 TT Paint Type
Deburring Tool -
Brush Cone Type for pipe 1/2" -2"
For Pint and Quart Cans DEB-2 1/2"to2"Pipe 1 6 710 108.26
KD-110 4-112" Length 25 0 710 10.62
KD-112 I 5-1/2"length 25 0 710 10.62
`s1"Brush wi1-3/4"Screw Cap.for pipe size 3/4"-2" -
Pa a 11 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears"Manufacturing Company
y Effective 02/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing
FlameGuard®Product
▪ Spears°Sprinkler Head Adapter Removal Kit& CPVC Riser Drain Valves For NFPA 13D Installations rr-
{ Only ®.
• Spears®Sprinkler Head Adapter Removal Kit CPVC Riser Drain Valves For NFPA 13D Installations
Only
Occasionally a Sprinkler Head Adapter may need to be removed for relocation,
extension or repair. Kit includes Cutter, Deburring Tool and Wrench. Cutter provides FlameGuardw CPVC Drain&Check Valves For NFPA 13D
easy cutting of pipe from the inside (using a power drill)to remove adapters without Applications Only
disturbing ceiling or side wall. Deburring Tool allows removal of burrs in cut pipe.
Wrench is designed to hold Spears®TorqueSafeTM Head Adapter brass insert from Application: FlameGuard®CPVC Orange Check Valves and PVC/CPVC True Union
rotating to aid in sp inkier head removal from adapter,if required. Drain Valves are for use in configuring CPVC Fire Sprinkler System connection to water
Part Number Size Std Mstr Prod MSRP supply(riser/drain assembly) in NFPA 13D installations only.These valves are not UL
Pk Ctn Code Listed and NOT for use in any other locations within the fire sprinkler system.
Complete Kit I Std Mstr Prod '
Part Number Size MSRP'
Inside Pipe Cutter,Deburring Tool and Pk Ctn Code
Wrench
SHRK-005 3/4"& 1"Pipe 1 15 299 660.31 True Union Industrial Drain Valve
With Locking Handle
Socket x Socket
CPVC Gray Valve with CPVC Orange End Connector
1822-007CFG 3/4 1 18 077 96.401
1822-010CFG 1 1 12 077 114.77
Inside Pipe Cutter Only 1822-012CFG 1-114 1 8 077 182.45 ii
IGSC-005 314"&1"Pipe 25 0 299 388.02 1822-015CFG 1-1/2 1 8 077 192.691
1822-020CFG 2 1 4 077 257.71
Not UL Listed
a
True Union Standard Drain Valves
Deburring Tool Only
GSB-005 I 3/4"&1" Pipe 25 0 299 447.66 Socket x Socket
PVC Gray Valve with CPVC Orange End Connector
3622-007FG 3/4 1 18 077 54.86
3622-010FG 1 1 12 077 65.34
Not UL Listed
Wrench Only
GSW-005 For 1/2 1 50 299 161.03 Compact 2000 Drain Valve
Socket x Socket
6622-007C0 3/4 10 80 077 i 37.65
6622-01000 1 10 0 077 , 47.07
Not UL Listed
CPVC Swing Check Valves
• Socket x Socket
S1520-1OCO 1 20 0 077 37.46
• S1520-12C0 1-1/4 12 0 077 41.86
S1520-15C0 1-1/2 12 0 077 47.07
Made in the U S.A. Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Page 12
Effective D2/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing
•
FlameGuard®Product -
il CPVC Riser Drain Valves For NFPA 13D Installations Only
CPVC Riser Drain Valves For NFPA 13D Installations
Only
Part Number Size Std.Mstr Prod MSRP
Pk Ctn Code
CPVC Swing Check Valves(continued)
Socket x Socket
'Not UL Listed
CPVC Special Reinforced Thread Inlet Swing
Check Valves
SR Fipt x Socket
S1520-1OFSRSCo 1 ! 20 0 077 40.57
S1520-12FSRSCO 1-1/4 12 0 077 46.83
S1520-15FSRSCO 1-1/2 12 0 077 55.57
Not UL Listed
General Installation Information: Socket end connections should be installed
using Spears®FS-5 One-Step Cement for use with Spears®CPVC Fire Sprinkler
Products.Threaded connections should be made using Spears®BLUE 751"'"
Thread Sealant tested for compatibility with CPVC materials. PVC True Union
Drain Valves are to be installed with system connection to Valve CPVC End
Connector.Swing check valves are designed for horizontal installations,but may
be installed in up-flow only vertical position.Check valves MUST be installed with
the valve's FLOW arrow pointing in the direction of the flow. Do not install valve
upside down.
•
Page 13 Suitable for Oil-Free air handling to 25 psi,not for distribution of compressed air or gas Spears.'Manufacturing Company
g Effective 02/01/2020 See MSRP-1 Sheet or Check Spears®On-line Catalog @ www.spearsmfg.com for Pricing