-,('‘S2v2 '-ctao6.-,i OFFICE COPY l/o70• (ogA /ono' NJ" RECEIVED MAY 1 2 820 NONNI' CITY OF GARD BUILDING Di VSON CORPORATION FIRE ALARM Notifier NEW-100X Addressable Fire Alarm System Notifier FCPS-24S6 Remote Power Supply Notifier N-ANN-80 Annunciator Panel Notifier NMM-100P Addressable Mini Input Module • Notifier NC-100R Addressable Mini Output Module Notifier NC-100 Addressable Control Module Notifier NBG-12LX Addressable Pull Station Notifier NP-200 Addressable Smoke Detector Notifier NH-200 Addressable Heat Detector System Sensor P2WL/SWL Horn Strobe/Strobe System Sensor P2WK Weatherproof Horn Strobe System Sensor HW-LF/P2WH-LF Low Frequency Sounder/Low Frequency Sounder Strobe System Sensor SCWL/PC2WL Ceiling Horn Strobe/Strobe 181 NOTIFIER ER- by Honeywell NFW-100X Intelligent Addressable FACP with Communicator General The FireWarden-100X(NFW-100X)is the latest intelligent address- able Fire Alarm Control Panel(FACP)within the FireWarden Series. The NFW-100X comes with a pre-installed communicator and sup- ports up to 198 addressable devices(99 detectors and 99 modules). With an extensive list of powerful features,the NFW-10OX programs NFW 100% just like FireWarden-100 products, yet fits into applications previ- ously served only by conventional panels. I The pre-installed IPOTS-COM is a dual technology (POTS and IP) 111111 communicator.The POTS transmits system status(alarms,troubles, AC loss,etc.)to a Central Station via the public switched telephones_ network.The IP communicator's internet monitoring capability sends �t�e alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines.Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line.Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file,walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a • One-person audible or silent walk test with walk-test log and metal cabinet. Available accessories include local and remote printout upload/download software, remote annunciators,and reverse polar- • System alarm verification selection per detector point ity/city box transmitter(4XTM). • PAS (Positive Alarm Sequence) and Pre-signal per point(NFPA Features 72 compliant) • Listed to UL Standard 864, 10th edition • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus • Pre installed IPOTS-COM Ethernet IP and POTS(Plain Old Tele- • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator phone Service)Central Station Communicator overAlarmNet • Upload/Download of program and data via USB with optional FS- • Optional CELL-MOD or CELL-CAB-N GSM Central Station Corn- Tools Programming Utility municator over AlarmNet® • Automated activation of the NFC-50/100 Emergency Command SLC COMMUNICATION LOOP Center • Supports FlashScan®and CLIP protocols • NFC-FFT Firefighter Telephone option • SLC operates up to 10,000 ft.(3,000 m)in FlashScan mode with • Compatible with SWIFT®wireless devices twisted, unshielded wire • Auto-programming (learn mode) reduces installation time. • Single addressable SLC loop which meets NFPA Class B and Reports two devices set to the same address Class A requirements • Four built-in, independently programmable Style Z (Class A) or • 198 addressable device capacity (99 addressable detectors and Style Y(Class B)NAC circuits p ty • Selectable strobe synchronization for System Sensor,Wheelock, 99 modules) and Gentex devices • Compatible with NOTIFIER FireWarden and ONYX Series • Notification Appliance Circuit End of Line resistor matching addressable devices (refer to the FireWarden SLC Wiring Man- • Four programmable function keys for ease of maintenance ua0 • Two programmable relays and one fixed trouble relay NOTIFICATION APPLIANCE CIRCUITS(NACS) • Built-in Programmer • Integral 80-character LCD display with backlighting • Four independently programmable output circuits. Circuits can • Real-time clock/calendar with automatic daylight savings control be configured for the following outputs: • History file with 1,000 event capacity —Style Y(Class B) • Addressable sounder base compatibility —Style Z(Class A) • Control module delay timer • Silence Inhibit and Autosilence timer options • Automatic detector sensitivity testing(NFPA72 compliant) • Continuous, March Time, Temporal, or California code for main • Automatic device type-code verification circuit board NACs with two-stage capability • Point trouble identification • Waterflow selection per module point • Selectable strobe synchronization per NAC • Alarm verification selection per detector point • 2.5 A special application,250mA regulated,total power for NACs • Maintenance alert warns when smoke detector dust accumula- NOTE:Maximum or total 24VDC system power shared between all NAC tion is excessive circuits and the ANN-BUS is 2.7 A DN-60959:A•3/6/2018—Page 1 of 4 PROGRAMMING AND SOFTWARE vised output for local energy municipal box transmitter, alarm and • Autoprogramming(learn mode)reduces installation time trouble.Includes a disable switch and disable trouble LED. • Custom English labels (per point) may be manually entered or PWRMOD24 Power Expander Module: Optional power module. selected from an internal library file Increases alarm power output to 6 amps. • Two programmable Form-C relay outputs COMPATIBLE ANNUNCIATORS • 99 software zones N-ANN-80: Remote LCD annunciator mimics the information dis- • Continuous fire protection during online programming played on the FACP LCD display. Recommended wire type is un- • Program Check automatically catches common errors not linked shielded.(Basic model is black;order-W for white;see DN-7114.) to any zone or input point N-ANN-100R:Remote LCD annunciator mimics the information dis- • OFFLINE PROGRAMMING: Create the entire program in your played on the FACP LCD display. Recommended wire type is un- office using FS-Tools,a Windowse-based software package,and shielded. For use in FM applications only. (Basic model is black; upload/download system programming locally. Offline program- order R for red.) ming requires an ethemet connection. FS-Tools is available on N-ANN-I/O:LED Driver Module provides connections to a user sup- www.notifier.com. plied graphic annunciator.(See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each User interface zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. LED INDICATORS (See DN-60242.) • Fire Alarm(red) CO Alarm(red) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points.(See DN-60242.) • AC Power(green) • Supervisory(yellow) N-ANN-RLY: Relay Module provides 10 programmable Form-C • Trouble(yellow) • Ground fault(yellow) relays.Can be mounted inside the cabinet.(See DN-7107.) • Battery fault(yellow) • Disabled(yellow) N-ANNS/PG: Serial/Parallel Printer Gateway module provides a • Maintenance(yellow) Communication(yellow) connection for a serial or parallel printer. (See DN-7103.) • Alarm Silenced(yellow) • F1-F4 Programmable Function ADDRESSABLE DEVICES Keys(yellow) FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. KEYPAD FSP-951-IV:Addressable low-profile photoelectric smoke detector. • 16 key alpha-numeric pad • Acknowledge Ivory.FlashScan and CLIP mode. • Alarm Silence • Drill(Manual Evacuate) NP-200: Addressable low-profile photoelectric smoke detector. • Four(4)programmable function keys • Reset(lamp test) B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. PRODUCT LINE INFORMATION Ivory,B300-6-IV base included.FlashScan and CLIP mode. NFW-100X: Addressable Fire Alarm Control Panel with one SLC FSP-951T: Addressable low-profile photoelectric smoke detector loop. Includes main circuit board with display chassis with trans- with thermal sensor.FlashScan only. former, backbox with door, plastic bag containing screws, cables, FSP-951T-IV:Addressable low-profile photoelectric smoke detector key,etc. with thermal sensor. Ivory.FlashScan and CLIP mode. FS-Tools: Programming software for Windows®-based PC corn- NP-200T:Addressable low-profile photoelectric smoke detector with puter.Available for download at www.notifier.com. thermal sensor. B300-6 base included. FlashScan only. CELL-CAB-N/CELL-MOD: Optional GSM communicators. NP-200T-IV:Addressable low-profile photoelectric smoke detector IPOTS-COM: Dual technology (POTS and IP) communicator. with thermal sensor. Ivory, B300-6-IV base included. FlashScan and (replacement board) CLIP mode. DP-ES-R:Optional dress panel for the NFW-100X(red). FSP-951R: Remote test capable addressable photoelectric smoke DP-ES-B:Optional dress panel for NFW-100X(black). detector for use with DNR(W) duct detector housing. FlashScan TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For only. red,order TR-CE.) FSP-951R-IV: Remote test capable addressable photoelectric BB-XP:Optional cabinet for one or two modules. smoke detector for use with DNR(W) duct detector housing. Ivory. BB-25: Optional cabinet for up to six modules mounted on CHS-6 FlashScan and CLIP mode. chassis. NP-200R: Remote test capable addressable photoelectric smoke BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- detector for use with DNR(W) duct detector housing. FlashScan 75. only. NFS-LBB: Battery box,houses two 55 AH batteries NP-200R-IV:Remote test capable addressable photoelectric smoke CHS-6:Chassis,mounts up to six multi-modules in a BB-25 cabinet. detector for use with DNR(W)duct detector housing. Ivory, FlashS- CHG-75:Battery charger for lead-acid batteries with a rating of 25 to can and CLIP mode. 75 AH. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. CHG-120: Remote battery charging system for lead-acid batteries FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- with a rating of 55 to 120 AH. Requires additional NFS-LBB for can and CLIP mode. mounting. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base NOTE:CHG-120 or CHG-75 required for batteries larger than 18AH. included, FlashScan only. BAT Series:Batteries,see data sheet DN-6933. NH-200-IV:Low-profile 135°F fixed thermal sensor. Ivory.B300-6-IV PRN Series: UL listed compatible event printer. Uses tractor-fed base included, FlashScan and CLIP mode. paper. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. OPTIONAL MODULES FlashScan only. FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. 4XTM Reverse Polarity Transmitter Module: Provides a super- Ivory.FlashScan and CLIP mode. Page 2 of 4—DN-60959:A•3/6/2018 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base zone of conventional two-wire detectors. Requires resettable 24 included,FlashScan only. VDC power. Refer to the Device Compatibility Document for listed NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- compatible devices and quantity limitation. IV base included, FlashScan and CLIP mode. NZM-100:Similar to NMM-100.Addressable Monitor Module for one • FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. zone of conventional two-wire detectors. Requires resettable 24 FlashScan only. VDC power. Refer to the Device Compatibility Document for listed FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- compatible devices and quantity limitation. sor.Ivory. FlashScan and CLIP mode. FCM-1:Addressable Control Module for one Style Y/Z(Class B/A) NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. zone of supervised polarized Notification Appliances. Mounts B300-6 base included,FlashScan only. directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NH-200H-IV: Low-profile intelligent 190F/88°C fixed thermal sen- NC-100:Addressable Control Module for one Style Y/Z(Class B/A) sor.Ivory.B300-6-IV base included, FlashScan and CLIP mode. zone of supervised polarized Notification Appliances. Mounts Legacy Devices directly to a 4.0" (10.16 cm.) electrical box. NAC option requires FSI-851:Addressable low-profile ionization smoke detector. external 24 VDC to power notification appliances. NI-100:Addressable low-profile ionization smoke detector. FRM-1: Addressable relay module containing two isolated sets of FSP-851:Addressable low-profile photoelectric smoke detector. Form-C contacts,which operate as a DPDT switch. Mounts directly NP-100:Addressable low-profile photoelectric smoke detector. to a 4.0"(10.16 cm.)box,surface mount using the SMB500. FSP-851T: Addressable low-profile photoelectric smoke detector NC-100R:Addressable relay module containing two isolated sets of with thermal sensor. Form-C contacts,which operate as a DPDT switch. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. NP-100T:Addressable low-profile photoelectric smoke detector with NBG-12LX:Addressable manual pull station with interface module thermal sensor. mounted inside. FSP-851 R: Remote test capable addressable photoelectric smoke NOT-BG12LX:Addressable manual pull station with interface mod- detector for use with DNR(W)duct detector housing. ule mounted inside. NP-100R: Remote test capable addressable photoelectric smoke ISO-X:Fault Isolator Module. detector for use with DNR(W)duct detector housing. FST-851:Fast-response,low-profile heat detector. N100-ISO:Fault Isolator Module. NH-100:Fast-response,low-profile heat detector. ISO-6:Six-fault isolator module.Mount one or two modules in a BB- FST 851 R: Fast-response, low-profile heat detector with rate-of-rise XP cabinet(optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. option. SMB500: Used to mount all modules except the FMM-101/NMM- NH-100R: Fast-response, low-profile heat detector with rate-of-rise 100P. option. NMM-100-10:Ten-input monitor module.Mount one or two modules FST-851H: Fast-response,low-profile heat detector that activates at in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 190°F/88°C. chassis in a BB-6F cabinet. NH-100H: Fast-response, low-profile heat detector that activates at NZM-100-6: Six-zone interface module. Mount one or two modules 190°F/88°C. in a BB-XP cabinet(optional). Mount up to six modules on a CHS-6 FAPT-851:Addressable low-profile multi-sensor detector. chassis in a CAB-3/CAB-4 series cabinet. • NP-A100:Addressable low-profile multi-sensor detector. SWIFT Wireless Devices B200SR:Addressable sounder base. FWSG:Wireless Gateway DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FWD-200P:intelligent,wireless photo detector. FSP-851R, FSP-951 R,or NP-100R separately.) FWH-200ROR135: LiteSpeed intelligent wireless rate of rise (135°) DNRW: InnovairFlex low-flow non-relay duct-detector housing,with heat detector. NEMA-4 rating. Watertight. (Order FSP-851 R, FSP-951 R, or NP- FWD-200ACCLIMATE:Wireless Acclimate Detector 100R separately.) FWH-200FIX135: intelligent wireless fixed-temperature (135°) heat Addressable Modules detector. FMM-1:Addressable Monitor Module for one zone of normally-open FW-MM:Intelligent wireless monitor module. dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) FW-RM: Intelligent wireless relay module. box. Includes plastic cover plate and end-of-line resistor. Module NBG-12LW: Intelligent wireless pull station. may be configured for either a Style B(Class B)or Style D(Class A) WAV-RL,WAV-WL,WAV-CRL,WAV-CWL:Intelligent AV bases. IDC. NMM-100:Addressable Monitor Module for one zone of normally- W-USB: Wireless USB radio/antenna dongle that plugs into the open dry-contact initiating devices. Mounts in standard 4.0" (10.16 USB port of a PC running SWIFT Tools. cm.)box. Includes plastic cover plate and end-of-line resistor. Mod- SWIFT Tools: Programming and diagnostic utility for the Wireless ule may be configured for either a Style B(Class B)or Style D(Class Gateway and devices.Available for download from firelite.com. A)IDC. NOTE: For more information on Compatible Addressable Devices for FDM-1: Monitor Same as NMM-100 except it provides use with the Fire Warden-100X,see the following data sheets(document two Style DualB(Class B)Module.IDCs. numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), only FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), vides two Style B(Class B)only IDCs. N100-ISO(DN-6994),NP-100 series(DN-6995),NH-100/NH-100R(ON- FMM-101: Miniature version of NMM-100. Excludes LED and Style NMM-100/NMM 100P/NOM-100/NZM-1006 0429),(ON 6999)A100 NC-(NP- �DO6998),(DN- D option.Connects with wire pigtails. May mount in device backbox. 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ NMM-100P:Miniature version of NMM-100.Excludes LED and Style FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12LX D option.Connects with wire pigtails.May mount in device backbox. (DN-7001), NBG-12LX (DN-6726), and Fire Warden SLC Manual FZM-1: Similar to NMM-100.Addressable Monitor Module for one (52304). DN-60959:A•3/6/2018—Page 3 of 4 SPECIFICATIONS System Capacity Addressable Device Accessories • Intelligent Signaling Line Circuits 1 End-of-Line Resistor Assembly (R-47K and R-3.9K): The • Addressable device capacity 198 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- Programmable software zones 99 100P, and NC-100 module circuits. The 3.9k ohm assembly super- • vises the NZM-100-6 module circuit. These resistors are included • Annunciators 16 with each module. Power Supervision Relay: Supervises the power to 4-wire smoke Electrical Specifications detectors and notification appliances. AC Power: 120/240 VAC,50/60 Hz,3.25 A.Wire size:minimum 14 Wiring Requirements AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, super- vised. While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger ence. Refer to the panel manual for wiring details. Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) NFPA Standards Communication Loop: Supervised and power-limited. The FireWarden-100X complies with the following NFPA 72 Fire Notification Appliance Circuits: Terminal Block provides connec- Alarm Systems requirements: tions for four NACs, Style Y(Class B) or Style Z(Class A). Special Application power. Power-limited, supervised circuitry. Maximum —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- signaling current per circuit: 2.5 amps special application, 250mA Supervi- sory). regulated. End-of-Line Resistor: 4.7k ohm, '% watt (P/N 71252 UL —AUXILIARY (Automatic, Manual and Waterflow) (requires listed)for Style Y(Class B) NAC;system capable of 1.9 kO-22 k0 4XTM). ELR range. Refer to the NOTIFIER Device Compatibility Document —REMOTE STATION (Automatic, Manual and Waterflow) for listed compatible devices. (Where a DACT is not accepted,the alarm,trouble and supervi- Two Programmable Relays and One Fixed Trouble Relay: Con- sory relays may be connected to UL 864 listed transmitters. For tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). reverse polarity signaling of alarm and trouble, 4XTM is Form-C relays, non-power-limited, non-supervised. required.) —PROPRIETARY(Automatic,Manual and Waterflow). Cabinet Specifications -CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" —OT, PSDN (Other Technologies, Packet-switched Data Net- (1.82 cm.)deep. Backbox: 19.00"(48.26 cm.) high x 16.65"(42.29 work) cm.)wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.)high x 19.65"(49.91 cm.)wide. —IBC 2012, IBC 2009,IBC 2006,IBC 2003, IBC 2000(Seismic). —CBC 2007(Seismic) Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high Agency Listings and Approvals x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. The listings and approvals below apply to the basic FireWarden- • 100X control panel. In some cases, certain modules may not be Temperature and Humidity Ranges listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. This system meets NFPA requirements for operation at 0—49°C/32 —120°F and at a relative humidity 93%±2% RH(noncondensing)at • UL: S635 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's • CSFM:7165-0028:0505 standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60— 80°F. IS® BlrlAI IlT arulla MIENS suurr srsrr�s This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate an requirements. All specifications are subject to change without notice. NOTIFIER AlarrnNel®,NOTIFIER®,Firewarde�,SWATS,and System Sensor® are registered trademarks of Honeywell International Inc.Microsoft®and 12 Clintonville Road Wndows®are registered trademarks of the Microsoft Corporation • , Northford,CT 06472 ®2018 by Honeywell International Inc.All rights reserved.Unauthorized N OT 1 F I E R 203.484.7161 use of[iris document is strictly prohibited. www.notifier.com Country of Origin:USA by Honeywell DF-52301:A2•D-025 FCPS-24FS6 JAreuTeALarms 24 Volt, 6 Amp Power Supply by Honeywell Power Supplies/Accessories General The Fire•Lite FCPS-24FS6(C/E) is a compact, cost-effec- tive, 6-amp remote power supplies with battery charger. The FCPS-24FS6(C/E)may be connected to any 12 or 24 volt fire alarm control panel(FACP)or may stand-alone.Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only.Alternately,the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors.The FFCPS-24FS6(C/E)also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FCPS- 24FS6(C/E)is ULC-listed. NOTE:Unless otherwise specified,the term FCPS-24FS6 used in this document refers to the standard FCPS-24FS6, FCPS- 24FS6C, FCPS-24FS6E Features • UL-Listed Notification Appliance Circuit(NAC)synchroniza- tion using System Sensor, Wheelock, or Gentex "Corn- mander2"appliances. • Operates as a "sync-follower" or as a "sync-generator' (default). See note on page 2. • Includes integral battery charger capable of charging up to • Contains two fully-isolated input/control circuits -triggered 18 AH batteries.Cabinet capable of housing 7.0 AH batter- - from FACP NAC (NAC expander mode)or jumped perma- ies. nently"ON"(stand-alone mode). • Battery charger may be disabled via DIP switch for applica- • Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 tions requiring larger batteries. • module)NACs(circuits 1 &3) • Fixed, clamp-type terminal blocks accommodate up to 12 • 6-amp full load output, with 3 amps maximum/circuit, in AWG(3.1mm2)wire. NAC expander mode(UL 864). • 4-amp continuous output in stand-alone mode(UL 1481). Specifications • Compatible with coded inputs;signals passed through. Primary(AC)Power: • Optional power-supervision relay(EOLR-1). • FCPS-24FS6: 120 VAC,60 Hz,3.2A maximum. • In stand-alone mode, output power circuits may be config- • FCPS-24FS6/E: 240 VAC,50 Hz, 1.6A maximum. ured as: resettable, (reset line from FACP required), • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- non-resettable,or a mix of two and two. lion. • Fully regulated and filtered power output-optimal for pow- Control Input Circuit: ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Trigger Input Voltage: 9 to 32 VDC. • Power-limiting technology meets UL power-limiting require- • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 ments. -16 V). • Form-C normally-closed trouble relay Trouble Contact Rating: 5 A at 24 VDC. • Fully supervised power supply,battery,and NACs. Auxiliary Power Output: Specific application power 500 mA • Selectable earth fault detection. maximum. • AC trouble report selectable for immediate 2-hour delay. Output Circuits: • Works with virtually any UL 864 fire alarm control which uti- • +24 VDC filtered, regulated. lizes an industry-standard reverse-polarity notification cir- • 3.0 A maximum for any one circuit. cuit(including unfiltered and unregulated bell power). Requires input trigger voltage of 9-32 VDC. • Total continuous current for all outputs(stand-alone mode): • Self-contained in compact, locking cabinet- 15"H x 14.5"W —FCPS-24F: 4.0 A maximum. • x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Total short-term current for all outputs(NAC expander mode): —FCPS-24F: 6.0 A maximum. DF-52301:A2.5/17/13—Page 1 of 4 Secondary Power(Battery)Charging Circuit: Agency Listings and Approvals • Supports lead-acid batteries only. These listings and approvals apply to the modules specified in • Float-charge voltage: 27.6 VDC. this document.In some cases,certain modules or applications • Maximum current charge: 250 mA. may not be listed by certain approval agencies,or listing may • Maximum battery capacity: 7.0 AH. be in process.Consult factory for latest listing status. • UL Listed: S2424,S1287 Applications • ULC Listed: S2424 Example 1: Expand notification appliance power an additional • CSFM Approved: 7315-0076:176 6.0 A. Use up to tour Class B(Style Y)outputs or four Class A • MEA: 387-94E (Style Z)outputs(using ZNAC-4).For example,the FACP noti- fication appliance circuits will activate the FOPS when reverse- Ordering Information polarity activation occurs.Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. FCPS-24FS6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure Example 2: Use the FOPS to expand auxiliary regulated 24- (15"H x 14.5'W x 2.75"D[cm:38.1 H x 36.83W x 6.985D)),and volt system power up to 4.0 A. Both resettable and non-reset- installation instructions. table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one FCPS-24FS6 is ULC-listed. or both of the FOPS inputs. FCPS-24FS6E: 6.0 A,240 VAC remote charger power supply. Example 3: Use addressable control modules to activate the Includes main printed circuit board, transformers, enclosure FOPS instead of activating it through the FACP notification (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D)),and appliance circuits.This typically allows for mounting the FOPS installation instructions. at greater distances" away from the FACP while expanding ZNAC-4: Class A(Style Y)NAC option module. system architecture in various applications. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire For example, an addressable control module is used to acti- smoke detector power. vote the FOPS,and an addressable monitor module is used to BAT 1270: Battery, 12-volt,7.0 AH(two required). sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control PS-1270: Battery, 12-volt,7.0 AH(two required). module. 90286: Optional module mounting kit, is required to install an "NOTE:Addressable FACPs are capable of locating control and addressable module on the power supply main circuit board. monitor modules at distances of up to 10,000 feet(3,046 meters) Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24FS6 can track(i.e."follow")the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FOPS. When the FCPS-24FS6 is configured(via DIP switch settings) as a"sync follower,"the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FOPS-24FS6 is configured(via DIP switch settings) as a"sync generator,"the FCPS's sync input terminals are not used. Rather,the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In"sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex)is selectable via DIP switch settings. Standards and Codes The FCPS-24FS6 complies with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4—DF-52301:A2.5/1 7/13 NOTE:All NAC outputs can be converted to Style Z with • Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output#4 Output#3 Output#2 Output#1 Output 24 VDC Specific �► Application Power AC NAC Control Power 41111.•1 Input#2 INPUT/OUTPUT (from FACP) FUNCTIONS are programmable by NAC Control SW1 DIP switch settings 1111m111111 Input#1 (from FACP) / NI Sync Input FCPS Battery Charger Simplified Block Diagram DF-52301:A2.5/17/13—Page 3 of 4 -o • cs H A y� ,O T82:Power-Limited, NAC/Out 1+ se. Supervised In NAC Mode NAC/Out 1- fq with Jumpers J5,JP6, NAGOut 2+ 71 erKj O CC TB1:Supervised JP7,8 JP8 In positions t4AGOut 2- ro .r shown below. NAC/Out 3+ o nr O Earth NAC/Out 3- Normally Open an AC Neutral NAC/Out 4+ Normally Closed —AC Hot NAGOut 4- Common �' TB5:Trouble Relay oO Form-C Fall-Safe AM- (drown energized) w 3XI a te CD TB2 i�� "'„�1( 1� 1�� O 3 i5. re - TB1 3 2 1 TB5 3 n non ,nnnn nnnn nnnn O • n gr JP1: o v 8 g �' I Ground Fault 5. m . rs 'uuuu- 'ilIIOQ uuuu 40IIQ Detection' d o J2 JP1 (cut to disable) m y T 5 m c r —ci Connectors 0 rrt • m 0 a W n N Q. N O n ill- 0 D m w c o a o JP3 JP28JP3: m m a `� a Q CodedlNon-Coded v 3 0' r o J1 0 Input Selection nr fe m 0 o F�2(n to ,-0 o g m .0 n Non-Power-Limited !s= o m .. c y m re O o J To Transformer tt2 O m 0 0 0 m a c 3 K r J To Transformer#1 Auxiliary Output to -Aux.Common 4 c 0 -m o 500 mA Specific- '( ,a a g o c S-m Application Power a u +Aux.24 VDC• 3 0 > > nw £ 9. N m' 3 0 8 -Control Input2 N O d N O. ^ . 0 m re = o'a .,_ 7 ° +Control input a. o a n m c 3�' n 1,12:: s -Out Common W O � A DT a y .�' F1 5 +puVTrouble Goofed 71 o a C C� m c 3 g 4 -,� -Control Input 1 3 m gm-5 xm F1: m = P 0 a n D Battery Fuse 3 +Control Input 1 fr 15A,30V Co D (� 2 , -Sync Input • m rp as JP4rill ` SW1 o 1 +Sync Input N m �° O .. C,©O ,,,:s a 0 TB4 *NOTE Auxiliary Power I Output Is power-IlMfed 2 m' I _Battery LEDs(L to R): SW1: but NOT supervised. y • W +battery 'AC Power(green) Programming • 0, •Ground Fault(yellow) DIP Switches m JP4:Supervised, •Battery Trouble(yellow) c y Non-Power-Limited •NAC Trouble(yellow) 5. o 0- 18 AH,24 VDC •Charger Trouble/AC Loss(yellow) C N er co C R. e w Si o NOTIFIER® by Honeywell N-ANN-80 80-Character Serial LCD Annunciator General • The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN- -.-- 80 and the FACP communicate over a two-wire serial interface ° A employing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The N-ANN-80 is black; for • white order N-ANN-80-W The N-ANN-80 displays English-language text of system point infor- mation w ) �ar� including device type,zone, independent point alarm,trouble ®NonRrce° +=► A & .l or supervisory status, as well as any custom alpha labels pro- 1 by Hnney.,o mom grammed into the control panel. It includes control switches for ""° 1 �°:EE aawEq remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-Bus of each } FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTI • - FIER FACPs with an ANN-Bus.such as the NFW-50X. Features • Trouble • Listed to UL Standard 864,9th Edition • Supervisory • Backlit 80-character LCD display(20 characters x 4 lines) • Alarm Silenced • Mimics all display information from the host panel • Control switches for System Acknowledge, Signal Silence, Drill, Specifications and Reset • Operating voltage range: 18 VDC to 28 VDC • Control switches can be independently enabled or disabled at the - Current consumption @ 24 VDC nominal (filtered and non- FACP resettable):40 mA maximum • Keyswitch enables/disables control switches and mechanically • Ambient temperature:32°F to 120°F(0°C to 49°C) locks annunciator enclosure • Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± • Keyswitch can be enabled or disabled at the FACP 2°C(90°F±3°F) • Enclosure supervised for tamper • 5.375" (13.65 cm.) high x 6.875"(17.46 cm.)wide x 1.375"(3.49 • System status LEDs for AC Power,Alarm, Trouble, Supervisory, cm.)deep and Alarm Silence • For use indoors in a dry location • Local sounder can be enabled or disabled at the FACP • All connections are power-limited and supervised • N-ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming The ANN-Bus • Displays device type identifiers, individual point alarm, trouble, supervisory,zone, and custom alpha labels POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- • Time-and date display field IARY POWER SUPPLY • Surface mount directly to wall or to single, double, or 4" square The ANN-Bus can be powered by an auxiliary power supply when electrical box the maximum number of ANN-Bus devices exceeds the ANN-Bus • Semi-flush mount to single, double, or 4" square electrical box. power requirements. See the FACP manual for more information. Use ANN-SB80KIT for angled view mounting ANN-BUS DEVICE ADDRESSING • Can be remotely located up to 6,000 feet (1,800 m) from the Each ANN-Bus device requires a unique address (ID Number) in panel order to communicate with the FACP.A maximum of 8 devices can • Backlight turns off during AC loss to conserve battery power but be connected to the FACP ANN-Bus communication circuit. See the will turn back on if an alarm condition occurs FACP manual for more information. • May be powered by 24 VDC from the host FACP or by remote WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT power supply(requires 24 VDC) • Up to eight N-ANN-80s can be connected on the ANN-Bus The N-ANN-80 connects to the FACP ANN-Bus communications cir- cuit.To determine the type of wire and the maximum wiring distance Controls and Indicators that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules • AC Power on a single 4-conductor bus. The total worst case current draw is • Alarm calculated by adding the individual worst case currents for each module. DN-7114,D•3/15/2018—Page 1 of 2 NOTE:For total worst case current draw on a single ANN-Bus refer to Agency Listings and Approvals appropriate FACP manual. The listings and approvals below apply to the N-ANN-80. In some WIRE REQUIREMENTS:POWER CIRCUIT cases, certain modules may not be listed by certain approval agen- • 14 to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power circuit is cies, or listing may be in process. Consult factory for latest listing acceptable. status. • All connections are power-limited and supervised. • UL:S635 • A maximum of eight N-ANN-80 modules may be connected to • FM approved this circuit. • CSFM: 7120-0028:0240 • MEA:442-06-E Vol.2 Ordering Options: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W:White,80 character LCD Annunciator. ANNSB80KIT-B:Black surface mount backbox with angled wedge. ANNSB80KIT-W: White surface mount backbox with angled wedge. ISO SMIMHI S S Y$1 1MR SSSllT STST 1 EME This document is not intended to be used for installation purposes. We try 1c keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements NOTI FI E R Al specifications are subject to change without notice. • 12 Clintonville Road NOTIFlER®isa regstered trademark of Honeywell International Inc. Northford,CT 06472 02016 by Honeywell International Inc.All rights reserved.Unauthorized N OT I F I ER' 203.484.7161 use add document is strictly prohibited. www.notlfierconl Country of Origin'USA by Honeywell INSTALLATION AND MAINTENANCE INSTRUCTIONS N OT I F I E R o m by Honeywell 12 Clintonville Road Northford,CT 06472-1653 NMM-100P Monitor Module Phone:203.484.7161 SPECIFICATIONS Nominal Operating Voltage: 15-32 VDC Operating Current: 350 pA max.,1 communication every 5 seconds,47K EOL resistor;600 pA max. (Communicating,IDC shorted) EOL resistance: 47K ohms Maximum SLC Wiring Resistance: 40 Ohms Maximum IDC Wiring Resistance: 1,500 Ohms Maximum IDC Voltage: 11 Volts Maximum IDC Current: 450pA Temperature Range: 32'F to 120°F(0'C to 49'C) Humidity: 10%to 93% Non-condensing Dimensions: 1.3"H x 2.75"W x 0.5"D Wire length: 6"minimum BEFORE INSTALLING MOUNTING AND WIRING This information is included as a quick reference installation guide. Refer to NOTE:This module is intended to be wired and mounted without rigid con- the control panel installation manual for detailed system information. If the nections inside a standard electrical box. All wiring must conform to appli- modules will be installed in an existing operational system,inform the opera- cable local codes,ordinances,and regulations. tor and local authority that the system will be temporarily out of service.Dis- 1. Connect the red (+) and black (-) wires to the positive and negative connect power to the control panel before installing the modules. loop power leads of the Signaling Line Circuit(SLC). NOTICE:This manual should be left with the owner/user of this equipment. 2. Connect the violet (+) and yellow (-) wires to a two-wire, normally GENERAL DESCRIPTION open initiating loop. The NMM-100P monitor module can be installed in a single gang junction box 3. Install the specified EOL resistor value to terminate the initiating loop. directly behind the monitored unit.Its small size and light weight allow it to 4. Set the address on the module per job drawings. be installed without rigid mounting(see Figure I).The NMM-10OP is intended 5. Install the module in the desired mounting location. for use in intelligent,two-wire systems where the individual address of each module is selected using rotary switches.It provides a two-wire initiating cir- FIGURE 2.TYPICAL 2-WIRE STYLE B INITIATING DEVICE CIRCUIT cult for normally open contact fire alarm and security devices. (IDC)CONFIGURATION: • COMPATIBILITY REQUIREMENTS UL LISTED To ensure proper operation, this module should only be connected to listed COMPATIBLE CONTROL SIGNAL LINE CIRCUIT(SLC) compatible system control panels only. PANEL ( TO FIGURE 1: (+) 11 _ J r�NEXT J DEVICE Y O m i °C 1-1 41 ALL WIRING " '-' SHOWN IS O SUPERVISED AND �� ' POWER LIMITED VIOLET • \ .50QYELLOW -��,� 47k EOL INCLUDED; j� ,\� , '< (ELR-47k) C0710-00 - Asa C0613-04 NO-460-013 I 156-3509-001 ©2007 Notifier ® NOTIFIER® W O 0 o NC-100R Relay Control Module Installation Instructions Specifications Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 6.5 mA (LED on) Average Operating Current: 230pA direct poll; 2551tA group poll EOL Resistance: Not used Temperature Range: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% Non-condensing Dimensions: 41/2" H x 4"W x 1'/4" D (Mounts to a 4" square by 21/8" deep box.) Accessories: SMB500 Electrical Box; CB500 Barrier Before Installing This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed Figure 1. Controls in an existing operational system, inform the operator and local authority that the system and indicators: will be temporarily out of service. Disconnect power to the control panel before installing f-1 O the modules. O IO Oo NOTICE: This manual should be left with the owner/user of this equipment. �1_ To General Description Ta „ The NC-100R Relay Control Module is intended for use in addressable, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. ,TB , T It allows a compatible control panel to switch discrete contacts by code command. The re- TO :e- 0- lay contains two isolated sets of Form-C contacts, which operate as a DPDT switch and are `� O TBp B °rrr rated in accordance with theGLJ(r table in the manual. Circuit connections to the relay contacts �O are not supervised by the module. The module also has a panel controlled LED indicator. how This module can be used to replace an C304 module that has been configured for Form-C Li O C0925A1 operation. Compatibility Requirements Figure 2A. Module To ensure proper operation, these modules shall be connected to mounting with barrier: listed compatible system control panels only. Mounting U The NC-I00R mounts directly to 4" square electrical boxes (see Figure 2A). The box must have a minimum depth of 2'/s". Surface /\ mounted electrical boxes (SMB500) are available. NOTE: All wiring must conform to applicable local codes, ordi- N44,4444::••••••/. nances, and regulations. When using control modules in non- power limited applications, the CB500 Module Barrier must be used to meet UL requirements for the separation of power-limited ,\, -, Figure 2B: and nonpower-limited terminals and wiring. The barrier must be inserted into a 4"x 4"x 21/s"junction box, and the control module „i must be placed into the barrier and attached to the junction box ; e- o . (Figure 2A). The power-limited wiring must be placed into the :'r.isolated quadrant of the module barrier (Figure 2B). �ye ji.31, lfl 1. Install module wiring in accordance with the job drawings and ®� �4 appropriate wiring diagrams. ,® ® �� ISOLATED 2. Set the address on the module per job drawings. .,� )®�, QUADRANT 3. Secure module to electrical box (supplied by installer), (3^60"°® CO927-0I as shown in Figure 2A. ®® � C0926-01 NO-460-007 1 156-3503-000 Notifier, 12 Clintonville Rd., Northford,CT 06472 Relay Contact Ratings: CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3 A 30 VDC Resistive Non-coded • 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-coded .9 A 125 VDC Resistive Non-coded .5 A 30 VDC Inductive(L/R=5ms) Coded 1 A 30 VDC Inductive(UR=2ms) Coded .3 A 125 VAC Inductive(PF=.35) Non-coded 1.5 A 25 VAC Inductive(PF=.35) Non-coded .7 A 70.7 VAC Inductive(PF=.35) Non-coded 2 A 25 VAC Inductive(PF=.35) Non-coded AWARNING All relay switch contacts are shipped in the standby state (open) state, but may have transferred to the activated (closed) state during shipping.To ensure that the switch contacts are in their correct state,modules must be made to communicate with the panel before connecting circuits controlled by the module. Figure S. Relay module wiring diagram: SIGNAL LINE CIRCUIT(SLC). 32 VDC Max. TWISTED PAIR CONNECT MODULES TO LISTED COMPATIBLE IS RECOMMENDED CONTROL PANELS ONLY TO NEXT I) HAN( FROM PANEL OR DEVICE I'I � (+)c PREVIOUS DEVICE CONTROL 1-1 MODULE Flo a oo n O (-) RELAY COMMON 2 11 NORMALLY CLOSED 2 (+) IF ANY WIRING TO TERMINALS 4-10 IS NONPOWER NORMALLY OPEN 2 LIMITED,THE CB500 BARRIER IS REQUIRED.THE CB500 RELAY COMMON 1 ip r UNUSED INCLUDES A NONPOWER LIMITED LABEL,WHICH MUST NORMALLY CLOSED 1 A NORMALLY OPEN 1 BE PLACED OVER THE POWER LIMITED TERMINAL INFORMATION ON THE NAMEPLATE LABEL. Iva a us 440 VlJ lJ MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS `NOTE:ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. CO924-03 NO-460-007 2 156-3503-000 02007 Nolifier DN-6999:E Monitor Modules ® NOT 1 F 1 E R® NMM-1OO(A), NMM-100P(A), NZM-10O(A), and NDM-1O0(A) for FireWarden Series by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- e , tact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire Q smoke detectors(NZM-100(A)). NMM-100(A)is a standard-sized module(typically mounts to a 4" [10.16 cm]square box) that supervises either a Style D • (Class A) or Style B (Class B) circuit of dry-contact input .> devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm)H x 2.75"(6.985 cm)W x 0.65"(1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. 4116 % i NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. NMM-100(A)(Type H) NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B to monitor normally-open supervisory devices with special (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM' is a communication protocol that greatly (provided) terminates the Style B circuit. No resistor is increases the speed of communication between analog intel- required for supervision of the Style D circuit. ligent devices. Intelligent devices communicate in a grouped NMM-100(A) OPERATION fashion. If one of the devices within the group has new infor- mation,the panel CPU stops the group poll and concentrates Each NMM-100(A) uses one of the available module on single points. The net effect is response speed greater addresses on an SLC loop. It responds to regular polls from than five times that of other communication protocols. the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing NMM-10O(A) Monitor Module LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to • Built-in type identification automatically identifies this current limitations on the loop). device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional NMM-100(A)SPECIFICATIONS power required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 375 pA(LED flashing), 1 corn- • Direct-dial entry of address: 01 —99 on FireWarden-100- munication every 5 seconds,47k EOL. 2, 01 —50 on FireWarden-50. Maximum IDC wiring resistance: 1500 Ohms. • LED flashes during normal operation and latches on Maximum IDC Voltage: 11 Volts. steady to indicate alarm. The NMM-100(A)Monitor Module is intended for use in intel- EOL resistance:47K Ohms. ligent, two-wire systems, where the individual address of Temperature range:32°F to 120°F(0°C to 49°C). each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Humidity range: 10%to 93%noncondensing. Device Circuit(IDC)for normally-open-contact fire alarm and Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x supervisory devices.The module has a panel-controlled LED 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x indicator. 2.125"(5.398 cm)deep box. NMM-100(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual NMM-10OP(A) Mini Monitor Module fire alarm pull stations, waterflow devices, or other normally- • Built-in type identification automatically identifies this • open dry-contact alarm activation devices. May also be used device as a monitor module to the panel. DN-6999•E•07/30/2015—Page 1 of 4 • Powered directly by two-wire SLC loop. No additional Wire length:6"(15.24 cm)minimum. power required. • High noise(EMF/RFI)immunity. NZM-100(A) Interface Module • Tinned,stripped leads for ease of wiring. • Supports compatible two-wire smoke detectors. • Direct-dial entry of address:01—99 on FireWarden-100-2, • Supervises IDC wiring and connection of external power 01 —50 on FireWarden-50. source. • High noise(EMF/RFI)immunity. N 3 1415 0 1 ADDRESS 0 1 • SEMS screws with clamping plates for ease of wiring. s 13 , 2 , 2 • Direct-dial entry entry of address:,01—99 on FireWarden- 3 2 4 LOOP 4 100-2,01 —50 on FireWarden-50. 10 5 5 • LED flashes during normal operation. 9 8 7 6 9 6 7 6 • LED latches steady to indicate alarm on command from TENS ONES control panel. n n n n The NZM-100(A) Interface Module is intended for use in intelligent, addressable systems, where the individual 3 address of each module is selected using built-in rotary o W p U switches. This module allows intelligent panels to interface J 0 W and monitor two-wire conventional smoke detectors. It trans- -.Icc ro mits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel.All two-wire detectors being monitored must be UL compatible with the module. I I I I NZM-100(A) APPLICATIONS The NMM-100P(A) Mini Monitor Module can be installed in a Use the NZM-100(A) to monitor a zone of two-wire smoke single-gang junction directly behind the monitored unit. Its detectors. The monitored circuit may be wired as an NFPA small size and light weight allow it to be installed without rigid Style B (Class B) or Style D (Class A) Initiating Device Cir- mounting. The NMM-100P(A) is intended for use in intelli- cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates gent, two-wire systems where the individual address of each the end of the Style B or D (class B or A) circuit (maximum module is selected using rotary switches. It provides a two- IDC loop resistance is 25 Ohms). Install ELR across termi- wire initiating device circuit for normally-open-contact fire nals 8 and 9 for Style D application. alarm and security devices.NMM-100P(A) NMM-100P(A)APPLICATIONS NZM-100(A)OPERATION Each NZM-100(A) uses one of the available module - Use to monitor a single device or a zone of four-wire smoke addresses on an SLC loop. It responds to regular polls from detectors, manual fire alarm pull stations,waterflow devices, the control panel and reports its type and the status (open/ or other normally-open dry-contact devices. May also be normal/short) of its Initiating Device Circuit(IDC).A flashing used to monitor normally-open supervisory devices with spe- LED indicates that the module is in communication with the cial supervisory indication at the control panel. Monitored cir- control panel. The LED latches steady on alarm (subject to cuit/device is wired as an NFPA Style B (Class B) Initiating current limitations on the loop). Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. NZM-100(A)SPECIFICATIONS NMM 100P(A)OPERATIONNominal operating voltage: 15 to 32 VDC. Each NMM-100P(A) uses one of the available module Maximum current draw:5.1 mA(LED on). addresses on an SLC loop. It responds to regular polls from Maximum IDC wiring resistance:25 Ohms. the control panel and reports its type and the status (open/ normal/short)of its Initiating Device Circuit(IDC). Average operating current: 270 NA, 1 communication and 1 LED flash every 5 seconds,3.9k eol. NMM-100P(A)SPECIFICATIONS EOL resistance:3.9K Ohms. Nominal operating voltage: 15 to 32 VDC. External supply voltage (between Terminals T10 and Average operating current: 350 pA, 1 communication T11): every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). • DC voltage:24 volts power limited. Maximum IDC wiring resistance: 1500 Ohms. • Ripple voltage: 0.1 Vrms maximum. • Current:90 mA per module maximum. Maximum IDC Voltage: 11 Volts. Temperature range:32°F to 120°F(0°C to 49°C). Maximum IDC Current:450 pA. Humidity range: 10%to 93%noncondensing. EOL resistance:47K Ohms. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Temperature range:32°F to 120°F(0°C to 49°C). 1.25" (3.175 cm)deep. Mounts to a 4" (10.16 cm) square x Humidity range: 10%to 93%noncondensing. 2.125"(5.398 cm)deep box. Dimensions: 1.3"(3.302 cm)high x 2.75"(6.985 cm)wide x • 0.65"(1.651 cm)deep. Page 2 of 4—DN-6999:E•07/30/2015 NDM-100(A) Dual Monitor Module • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- The NDM-100(A) Dual Monitor Module is intended for use in 100);7300-0028:0237(NDM-100). intelligent, two-wire systems. It provides two independent two- • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); wire initiating device circuits(IDCs)at two separate,consecutive 227-03-E Vol.3(NDM-100). addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- Product Line Information controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B) IDC cir- NOTE:"A"suffix indicates ULC-listed model. cuits ONLY Style D (Class A) IDC circuits are NOT supported in NMM-100(A): Monitor module. any application. NMM-100P(A): Monitor module, miniature. NDM-100(A) SPECIFICATIONS NZM-100(A):Monitor module,two-wire detectors. Normal operating voltage range: 15 to 32 VDC. NDM-100(A): Monitor module, dual, two independent Class Maximum current draw:6.4 mA(LED on). B circuits. Average operating current:750 pA(LED flashing). SMB500:Optional surface-mount backbox. Maximum IDC wiring resistance: 1,500 Ohms. NOTE: See installation instructions and refer to the SLC Wiring Maximum IDC Voltage: 11 Volts. Manual,PN 52304. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range: 32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. NDM-100(A)AUTOMATIC ADDRESSING The NDM-100(A)automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the NDM-100(A) are 0, 2, 4, 6, or 8 only Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A)modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635. • ULC:S635. • FM Approved. DN-6999:E•07/30/2015—Page 3 of 4 Nattier®and FireWarden®are registered trademarks and LiteSpeed' and FireWatchTM are trademarks of Honeywell International Inc. ®2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO w 0 �o o+1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E fi T F E O We cannot cover all specific applications or anticipate all requirements. ft;Ir fulNR&MNiIMRCTRRING All specifications are subject to change without notice. OUAIITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:E•07/30/2015 Wiring IIIII NOT-BG1 2LX 0 N OT I F I E R N Addressable Pull Station Next Document 52135 156-3515-000 Addressable by Honeywell From FACP Device + + —SLC NOT-BG12LX Addressable Pull Station SLC— i� Patented, U.S.Patent No.Des.428,351;6,380,846;Other Patents Pending 1p n im, 40, Document 52135 1563515-000 0 o I I— o O eeo ® 0 E U 1.:,,j E Description 1.1111.1111na„M°r i �: The NOT-BG12LX Addressable pull station is a non-coded,dual-action manual pull station I �C� •' with a key-lock reset feature.It provides Notifier's FireWarden-100,a 198-point addressable _!' o ���pc")°o fire alarm control panel,with one addressable alarm initiating input.The addressable module t,Te W Nis housed inside the ull station and ma be accessed b o enin the door without initiat- ing an alarm..The NOT-BG12LX meets the ADAAG controls and operating mechanisms a„,ril /J L guidelines(section 4.1.3[13]),and the ADA requirement for a 5 lb.maximum pull force to 0 0 activate the pull station.Operating instructions are molded into the pull station handle along 0 3 0 with Braille text.Molded Terminal numbers are also present. Ill NOT �J v 8 bYHontRt@It. Q �, e7�vell °� Ratings 1 ® oil Operating Voltage:24 VDC. Average Operating Current(LED Flash): 300 1,A. Temperature Range:32°F- 120°F(0°C-49°C). Relative Humidity Range: 10%-93%non-condensing. Installation CAUTION!Do not detach the door of the pull station during installation.The door of The NOT-BG12LX Addressable pull station can be surface mounted to an SB-10 or SB-I/O the pull station cannot be reattached to the backplate after the backplate has already been surface hackbox or semi-flush mounted on a standard single-gang,double-gang or 4"(10.16 installed onto an electrical box. cm)square electrical box.The optional BG-TR trim ring can be used if the NOT-BG12LX CAUTION! is to be semi-flush mounted. Install the Notifier NOT-BG12LX addressable pull station in accordance with these Operation instructions,applicable NFPA standards,national and local Fire and Electrical codes To activate the dual-action pull station, push in and pull down on the handle. The word and the requirements of the AHJ(Authority Having Jurisdiction).Regular testing of the `ACTIVATED'appears after the handle is pulled down.This will remain until the pull sta- devices should be conducted in accordance with the appropriate NFPA standards.Failure tion is reset. to follow these directions may result in failure of the device to report an alarm condition. Notifier is not responsible for devices that have been improperly installed,tested or main- The pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) tained. switch which closes upon activation of the pull station. ADA Compliance Resetting the Pull Station 1 For ADA compliance,if the clear floor space only allows forward approach to an object,the 1.Insert the key into the lock and rotate 1/4 turn counterclockwise. maximum forward reach height allowed is 48 inches(121.92 cm).If the clear floor space 2.Open the door until the handle returns to normal. allows parallel approach by a person in a wheelchair,the maximum side reach allowed is 3.Close and lock the door. 54 inches(137.16 cm). NOTE: Closing the door automatically resets the switch to the`Normal'position.Open- ing the door will not activate or deactivate the alarm switch. (over for Programming reformation)w Setting the NOT-BG12LX Address Mill The NOT-BG12LX Addressable pull station is factory preset with address `00.'Set the ad- dress for the pull station by turning the rotary address switches on the addressable module mounted inside the pull station.Only one device per address is allowed.Multiple modules may not be set to the same address on the Signaling Line Circuit. Once the address is set, record it in the space provided on the product ID label located inside the pull station. ROTARY ADDRESS SWITCHES LED = LED OPERATION I I 0 Normal: Flash RED O C 0 E Alarm: Steady RED2 lil Note:LED is visible Vo7._. 2 through translucent O handle. O s 0 s O 4 4 6 5 ® 9 6 5 8 TENS ONES Note—Opening the L 0 P�pull station door O M will not activate or t1 deactivate the alarm switch. •,---WI n I!ACTS"7Z-D o o PRODUCT IDENTIFICATION LABEL I 1 ' / NOTIFIERE by Honeywell NP-200 Series Photoelectric Smoke Detectors for FireWarden Series The NOTIFIER®NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the NP-100 Series.A new modern, sleek, contem- porary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series address- able fire alarm control panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency * � a s personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indi- ' „T cation. +� The NP-200 Series also offers 135°F(57°C)fixed temperature ther- mal sensing on the NP-200T and a remote test capable detector on the NP-200R for use with DNR(A)/DNRW duct smoke detector housings. Features • Separate base allows interchange of photoelectric, ionization and SLC LOOP: thermal sensors • Two-wire SLC loop connection OPTIONS: • Unit uses base for wiring • Optional relay,isolator, and sounder bases • Compatible with FlashScan®and CLIP protocol systems Installation • Stable communication technique with noise immunity NP-200 Series plug-in intelligent smoke detectors use a detachable ADDRESSING: base to simplify installation, service and maintenance. Installation • • Addressable by device instructions are shipped with each detector. • Rotary,decimal addressing Mount detector base(all base types)on an electrical backbox which (Refer to the FireWarden panel manuals for device capacity.) is at least 1.5" (3.81 cm) deep. For a chart of compatible junction ARCHITECTURE: boxes,see DN-60054. • Sleek, low-profile,stylish design NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps"or branches are • Unique single-source design to respond quickly and dependably permitted for Style 4(Class"B")wiring only to a broad range of fires When using relay or sounder bases, consult the N100-ISO installation • Integral communications and built-in device-type identification sheet 156-3625 for device limitations between isolator modules and iso- • Built-in tamper resistant feature latorbases. • Remote test feature from the panel Construction • Walk test with address display (an address on 121 will blink the These detectors are constructed of fire-resistant plastic.The NP-200 detector LED: 12-[pause]-1(FlashScan systems only) Series plug-in intelligent smoke detectors are designed to commer- • Built-in functional test switch activated by external magnet cial standards and offer an attractive appearance. • Removable cover and insect-resistant screen for simple field cleaning Operation • Expanded color options Each NP-200 Series detector uses one of the panel's addresses (total limit is panel dependent)on the FireWarden Signaling Line Cir- OPERATION: cuit (SLC). It responds to regular polls from the control panel and • Designed to meet UL 268 7th Edition reports its type and the status.If it receives a test command from the • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- panel (or a local magnet test), it stimulates its electronics and old level reports an alarm. It blinks its LEDs when polled and turns the LEDs • LED"blinks'when the unit is polled (communicating with the fire on when commanded by the panel. The NP-200 Series offers fea- panel)and latches in alarm. tures and performance that represent the latest in smoke detector technology. • Low standby current MECHANICALS: Detector Sensitivity Test • Sealed against back pressure Each detector can have its sensitivity tested(required per NFPA 72, SEMS screws for wiring of the separate base Chapter 14 on Inspection, Testing and Maintenance)when installed/ connected to an FireWarden Series addressable fire alarm control • Designed for direct-surface or electrical-box mounting panel. The results of the sensitivity test can be printed for record • Plugs into separate base for ease of installation and maintenance keeping. • DN-60979:8•7/1/2019—Page 1 of 3 Product Line Information B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- NOTE:"-IV"suffix indicates CLIP and FlashScan device. 10% with a square wave or its equivalent; designed to meet the NP-200: White, low-profile intelligent photoelectric sensor, FlashS- NFPA 72 sleeping space requirement. Intended for retrofit applica- can only tions.(CSFM:7300-1653:0238) NP-200-IV: Ivory,low-profile intelligent photoelectric sensor MOUNTING KITS AND ACCESSORIES NP-200T:White,same as but includes a built-in 135°F(57°C)fixed- TR300:White, replacement flange for B210LP(A)base temperature thermal device, FlashScan only TR300-IV: Ivory,replacement flange for B210LP(A)base NP-200T-IV: Ivory, same as T but includes a built-in 135°F (57°C) RA100Z(A):Remote LED annunciator.3-32 VDC.Mounts to a U.S. fixed-temperature thermal device single-gang electrical box. For use with B501(A)and B300-6(A). NP-200R:White, low-profile intelligent photoelectric sensor, remote M02-04-00:Test magnet test capable,for use with DNR/DNRW, FlashScan only M02-09-00:Test magnet with telescoping handle NP-200R-IV: Ivory, low-profile intelligent photoelectric sensor, CK300:Color Kit(includes cover and trim ring),white, 10-pack remote test capable,for use with DNR/DNRW CK300-IV:Color Kit(includes cover and trim ring), ivory, 10-pack INTELLIGENT BASES CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack NOTE:For details on intelligent bases, see DN-60981. B300-6:White,6"base,standard flanged low-profile mounting base (CSFM:7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base(CSFM:7300-1653:0109) B300-6-BP:Bulk pack of B300-6, package contains 10 13501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed(CSFM:7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed(CSFM:7300-1653:0109) 8501-IV: Ivory color, 4" standard European flangeless mounting base.UUULC listed(CSFM:7300-1653:0109) B501-WHITE-BP:Bulk pack of B501-WHITE contains 10 B224RB-WH:White,relay base(CSFM:7300-1653:0216) B224RB-IV:Ivory,relay base(CSFM:7300-1653:0216) B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B200S-WH:White, Intelligent addressable sounder base capable of • producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA72 sleeping space requirement.(CSFM:7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) B200SR-WH:White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM:7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM: 7300-1653:0213) B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions.(CSFM:7300-1653:0238) Page 2 of 3—DN-60979:B•7/1/2019 SPECIFICATIONS Sensitivity: Listings and Approvals • ULApplications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the NP-200 Series detectors. • ULC Applications:0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0"(5.3 cm)high;base determines diameter approval agencies, or listing may be in process. Consult factory for latest listing status. —B300-6:6.1"(15.6 cm)diameter —B501:4"(10.2 cm)diameter • UUULC Listing:Sills • For a complete list of detector bases see DN-60981 FM Approved • CSFM:7272-0028:0503 Shipping weight:3.4 oz.(95 g) Operating temperature range: • NP-200:32°F to 122°F(0°C to 50°C) • NP-200T Series:32°F to 100°F(0°C to 38°C) • NP-200R Series installed in a DNR/DNRW, -4°F to 158°F(-20°C to 70°C) UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 mlmin.), suitable for installation in ducts Relative humidity:10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of- rise detection 15°F(8.3°C)per minute,high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200µ4 @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet(9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. �S® OSAIIR IIIY SYSTEMS Q IIAIITY ITEIEMI This document is not intended to be used for installation purposes. We by to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. NOTIFIER Jl specifications are subject to change Othout notice. FreNiarden®.FIasrScan®,NOTIFIER®,and System Sensor®are rags- 12 Clintonville Road tend trademarks of Honeywell International.Inc R. Northford,CT 06472 62019by Honeywell International Inc All rights reserved.Unauthorized ® NOTIFIER 203.484.7161 use of this document a strictly prohibited. www.notifter.com Country of Origin:Mexico by Honeywell NOTI FI ER by Honeywell NH-200 Series Addressable Heat Detectors for FireWarden Series The NOTIFIER® NH-200 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the NH-100 Series.A new modern,sleek,contem- porary design and advanced thermal technologies make the NH-200 Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches, provide speck .-} detector locations. Compatible with FireWarden® Series fire alarm control panels, the series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors.These thermal deter- tors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan®and CLIP applications as designated. Features SLC LOOP: • Two-wire SLC loop connection • Unit uses base for wiring ADDRESSING: • Flanged surface mounting kit • Addressable by device • Rotary,decimal addressing Installation (Refer to the FireWarden panel manuals for device capacity.) NH-200 Series plug-in intelligent thermal detectors use a detachable ARCHITECTURE: base to simplify installation, service and maintenance. Installation • Designed to meet UL 268 7th Edition instructions are shipped with each detector. • Sleek,low-profile,stylish design Mount detector base(all base types)on an electrical backbox which • State-of-the-art thermistor technology for fast response is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes,see DN-60054. • Integral communications and built-in device-type identification Built-in tamper resistant feature NOTE:Because of the inherent supervision provided by the SLC loop, • end-of-line resistors are not required. Wiring "T-taps"or branches am • Built-in functional test switch activated by external magnet permitted for Style 4(Class"B"wiring only. When using relay or sounder bases, consult the N100-ISO installation OPERATION: sheet 156-3625 for device limitations between isolator modules and iso- • Fixed temperature model (NH-200) factory preset to 135°F lator bases. (57°C) • Rate-of-rise model(NH-200R),15°F(8.3°C)per minute Applications • High-temperature model (NH-200H) factory preset to 190°F Use thermal detectors for protection of property.For further informa- (88°C) tion, refer to 156-6522, Applications Manual for System Smoke • 360°-field viewing angle of the two visual alarm indicators, LEDs Detectors,which provides detailed information on detector spacing, blink red in Normal condition and turn on steady red in Alarm placement,zoning,wiring,and special applications. • LEDs blink every time the unit is polled Construction MECHANICALS: These detectors are constructed of fire-resistant plastic. The NH- • Sealed against back pressure 200 Series plug-in intelligent thermal detectors are designed to corn- • SEMS screws for wiring of the separate base mercial standards and offer an attractive appearance. • Designed for direct-surface or electrical-box mounting • Plugs into separate base for ease of installation and maintenance Operation • Separate base allows interchange of photoelectric, ionization and Each NH-200 Series detector uses one of the panel's addresses thermal sensors (total limit is panel dependent)on the FireWarden Signaling Line Cir- cuit(SLC). It responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the • Remote test feature from the panel panel (or a local magnet test), it stimulates its electronics and • Walk test with address display reports an alarm. It blinks its LEDs when polled and turns the LEDs • Low standby current on when commanded by the panel. The NH-200 Series offers fea- tures and performance that represent the latest in thermal detector OPTIONS: technology. • Remote LED output connection to optional RA100Z remote LED annunciator • DN-60960:B•6/26/2019—Page 1 of 3 Product Line Information B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable NOTE:"-IV"suffix indicates CLIP and FlashScandevice. sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NH-200: White, low-profile intelligent 135°F fixed thermal sensor, NFPA 72 sleeping space requirement. Intended for retrofit applica- FlashScan only tions.(CSFM:7300-1653:0238) NH-200-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, MOUNTING KITS AND ACCESSORIES FlashScan and CLIP TR300:White,replacement flange for B210LP(A)base NH-200R: White, low-profile intelligent rate-of-rise thermal sensor, TR300 IV:Ivory,replacement flange for B210LP(A)base FlashScan only NH-200R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal RA100Z:Remote LED annunciator.3-32 VDC.Mounts to a U.S.sin- sensor,FlashScan and CLIP gle-gang electrical box.For use with 13501(A)and B300-6(A). NH-200H: White, low-profile intelligent 190°F fixed thermal sensor, M02-04-00:Test magnet FlashScan only M02-09-00:Test magnet with telescoping handle NH-200H-IV: Ivory, low-profile intelligent 190°F thermal sensor, CK300:Color Kit(includes cover and trim ring),white, 10-pack FlashScan and CLIP CK300-IV:Color Kit(includes cover and trim ring), ivory, 10-pack INTELLIGENT BASES CK300-BL:Color Kit(includes cover and trim ring),black, 10-pack NOTE:For details on intelligent bases,see DN-60981. B300-6:White,6"base,standard flanged low-profile mounting base (CSFM:7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base(CSFM:7300-1653:0109) B300-6-BP:Bulk pack of B300-6,package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base.UUULC listed(CSFM:7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UUULC listed(CSFM:7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base.UUULC listed(CSFM:7300-1653:0109) B501-WHITE-BP:Bulk pack of B501-WHITE contains 10 B224RB-WH:White,relay base(CSFM:7300-1653:0216) B224RB-IV: Ivory,relay base(CSFM:7300-1653:0216) B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224B1-IV: Ivory isolator detector base(CSFM: 7300-1653:0216) B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) B200SR-WH:White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM:7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM:7300-1653:0213) B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- - tions.(CSFM:7300-1653:0238) • Page 2 of 3—DN-60980:B•6/26/2019 SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5%to 3.5% Size:2.0"(5.3 cm) high; base determines diameter —B300-6:6.1"(15.6 cm)diameter —B501: 4"(10.2 cm)diameter For a complete list of detector bases see DN-60981 Shipping weight: 3.4 oz.(95 g) Operating temperature range: • NH-200, NH-200R Series:—4°F to 100°F(-20°C to 38°C) • NH-200H Series:-4°F to 150°F(-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m) center-to-cen- ter, FM approved for 25 x 25 ft. (7.62 x 7.62 m)spacing Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C), rate-of- rise detection 15°F(8.3°C)per minute. high temperature heat 190°F (88°C) Mounting: B300-6(A)flanged base, included See "Product Line Information: Intelligent Bases," if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.): 200NA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA@ 24 VDC("ON") Listings and Approvals Listings and approvals below apply to the NH-200 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listing: S747 • FM Approved • CSFM:7270-0028:0502 ISO MIMICS I MMIIMIMM SMITE SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-10-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to charge without notice. NOTIFIER FireWardenC.FlasnScae®.and NOTIFIERM are registered Irademarns of 12 Clintonville Road Honeywell International,Inc ® E Northford,CT 06472 b2019by Honeywell International Inc.All rights reserved_Unauthoroed NOT 1 F I E R® 203.484.7161 use of this document is strictly prohibited. �� Honeywell www.notifiercom Country of Origin'.Mexico Th SYSTEM � SENSOR' F '1'1'1'1' F Indoor Selectable- 471,e , Output Horns, E Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification „r ,T •-z . ra products are rich with features guaranteed to cut �a L*' s - tit installation times and maximize profits with lower r current draw and modern aesthetics. Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING .001 .® 'i LISTED 55512 FM approveo except 7125-1853O6aa 5a011 for ALERT models 7135-16530503 3057383.3057072 AVDS8ES-04•11/17/2017•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1.2 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25-D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133mm L x 88mm W x 32mm D) 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVD5865-04•11/17/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC . DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 • 10* 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the hor^output remains constantly on. - AVDSe55-04•11/17/2017•Page 3 L-Series Dimensions 1.91' �— 3.42" �_ SAS" 42.5mm $8mm 1.25" 9.57'' 1.55" 99mm - t25' 32mm 19.1 me) I (3.92m) ! 1/ C&YAM ' � 189.Emm 19mm59 .r 1rj4 j4 (� c� �/ \Ifl-• I11111p111111p1 I11111.1 (19.7 an) O t 0 - 11111 � �� A0548-00 A0547-00 A0557.00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70" (11.94 cm) 1.91" I l (ae"Cm) 118 mm 4.22 tK• 1.25" 82 mm (1222 em) (am cm) —__. (3.18 mm) a ��_—,.,.., �� a.J-1 w_ ® o\\ •r+ ui "5.87" '14 an) O It+•a (14.4 cm) INm oa, '�o' L°E. /� IIi!r}f Gam' �1111111 n � _o_jJ _ ' A0550-00 A0549-00 1,0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns - P2RL 2-Wire,Horn Strobe, Red HRL Horn,Red P2WL 2-Wire,Horn Strobe,White HWL Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red P2GWL 2-Wire,Compact Horn Strobe,White HGWL Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4RW 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe, Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover *T SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 02ov System Sensor. I Phone:800-SENSOR2•Fax:630-377-6495 Prcductspeclticalions subject to changewnhout nosoe.Visitsystemsensoccam SENSOR' for current product Information,Including the latest version of this data sheet. 'v ^ www.systemsensor.com 5vcsse5-04.1111 7/2 01 7 SYSTEM SENSOR' •`' T ?;dLx Outdoor Selectable- Output Horns, Strobes, and Horn Strobes r SpectrAlert°Advance outdoor selectable-output horns, , "`' strobes,and horn strobes are rich with features that �y��� cut installation times and maximize profits. SPECTRAlert A V A IV C E Features The SpectrAlert Advance series offers the broadest line of -Automatic selection of 12-or 24-volt operation at 15 and 15/75 outdoor horns,strobes,and horn strobes in the industry.With candela white and red plastic housings,wall and ceiling mounting options, and plain and FIRE-printed devices,SpectrAlert Advance can meet •Field-selectable candela settings on wall and ceiling units:15,15/75, virtually any application requirement. 30,75,95,110,115,135,150,177,and 185 •Plug-in design with minimal intrusion into the back box SpectrAlert Advance outdoor horns,strobes,and horn strobes can •Tamper-resistant construction be used indoors or outdoors in wet or dry applications,and can •Universal mounting plate for wall-and ceiling-mount units provide reliable operation from—40°F to 151°F. •Mounting plate shorting spring tests wiring continuity before Like the entire SpectrAlert Advance product line,these devices devices are installed include a variety of features that increase their application versatility •Weatherproof per NEMA 4X,IP56 while simplifying installation.All devices feature plug-in designs with •Listed to UL 1638(strobe)and UL 464(horn) minimal intrusion into the back box,which make installations fast •Rated from—40°F to 151°F and foolproof while virtually eliminating costly and time-consuming ground faults. •Horn rated at 88+dBA at 16 volts •Rotary switch for horn tone and three volume selections All horns,strobes,and horn strobes use a universal mounting plate •Compatible with System Sensor synchronization protocol and with an onboard shorting spring that tests wiring continuity before legacy SpectrAlert products the device is installed,protecting devices from damage.In addition, field-selectable candela settings,automatic selection of 12-or 24- volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALING UL LISTED ; ®5 MEA 73 0tri 6$}IB i(outdoor Etches) aPProvd7125-155318emmetrnese54011(chimes,horn sant,1,n, APPROVED Si93(outdoor and alert 302172 MEA452,15-E 7135-1653 184(horns.chimes) SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync•Circuit'Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,1 15,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobes entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.I hese options shall be set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangez 8 to 17.5 V(12V nominal)or 16 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mmW x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mmW x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(14S mm L x 130 mmW x 51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions(SA-WBBC) 7.1-diameter x 2.0-high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. ans-o456+x11 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 • Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) • 16-33 Volts 16-33 Volts DClnput 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn Strobe Output(dBA) ratings must be reduced in accordance with this table, 24-Volt Nominal Strobe Output(cd) 8-17.5 16-33 Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non Temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non Temporal Low 75 75 81 81 88 84 96 92 115 115 7' Coded High 82 82 88 88 93 92 101 101 135 135 83 Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 • 177 177 'Settings 7,8,and 9 arc not available on 2-wire horn strobe. 185 18S A05-0=56-001 SpectrAlert Advance Dimensions 4.7 2.5"—ia 6.8 Du. 1■ ■1 I. 1/— /I 1/ $J! : II !IIIP' Wall-mount horn strobes Ceiling-mount horn strobes h yp• Dia. V!:; y � 5.]" 1. O Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor P2RHK't 2-Wire Horn Strobe,High cd,Red,Outdoor PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor P2WK"t 2-Wire Horn Strobe,Standard cd,White,Outdoor PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor - P2WHK"t 2-Wire Horn Strobe,High cd,White,Outdoor PC2WHK 2-Wire,Horn Strobe High cd,White,Outdoor P4RKt 4-W re Horn Strobe,Standard cd,Red,Outdoor PC4WK 4-Wire,Horn Strobe,Standard cd,White,Outdoor P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor PC4WHK 4-Wire,Horn Strobe,High cd,White,Outdoor P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120V Ceiling Strobes Wall Strobes SCRK Strobe,Standard cd,Red,Outdoor SRK't Strobe,Standard cd,Red,Outdoor SCRHK Strobe,High cd,Red,Outdoor SRHK"' Strobe,High cd,Red,Outdoor SCWK Strobe,Standard cd,White,Outdoor SWK't Strobe,Standard cd,White,Outdoor SCWHK Strobe,High cd,White,Outdoor SWHK" Strobe,High cd,White,Outdoor Horns HRK Horn,Red,Outdoor Notes: `Add"-P"to model number for plain housing(no•FIRE"marking on cover),e.g.,P2RK-P t Add"-R•to model number for weatherproof replacement device(no back box included),especially for use with weatherproof outdoor flush mounting plate,WiP and WTPW. 'Standard cd'refers to strobes that include 15,15/75,30,75,9S,110,and 115 candela settings."High ccPrefers to strobes that include 135,150,177,and 185 candela settings. �� ✓I STEM 0200a System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subbente.change without nonce.Vsrtsysremsensormm far �$ SENSOR" Phone:800-SENSOR2•Fax:630-377-6495 current product inrnrnaaon,in:iad the latest version d this data sheet. Ans-nasfAol.116/09.4 21 90 *, Th, SYSTEM SENSOR' tki4 Outdoor Selectable- F 1 r • Output Horns, Strobes, itan. and Horn Strobes SpectrAlert°Advance outdoor selectable-output horns, �. strobes,and horn strobes are rich with features that p cut installation times and maximize profits. SPECTF Alert A IV C Features The SpectrAlert Advance series offers the broadest line of •Automatic selection of 12-or 24-volt operation at 15 and 15/75 outdoor horns,strobes,and horn strobes in the industry.With candela white and red plastic housings,wall and ceiling mounting options, and plain and FIRE-printed devices,SpectrAlert Advance can meet •Field-selectable candela settings on wall and ceiling units:15,15/75, virtually any application requirement. 30,75,95,110,115,135,150,177,and 185 •Plug-in design with minimal intrusion into the back box SpectrAlert Advance outdoor horns,strobes,and horn strobes can •Tamper-resistant construction be used indoors or outdoors in wet or dry applications,and can •Universal mounting plate for wall-and ceiling-mount units provide reliable operation from—40°F to 151°F. •Mounting plate shorting spring tests wiring continuity before Like the entire SpectrAlert Advance product line,these devices devices are installed include a variety of features that increase their application versatility •Weatherproof per NEMA 4X,IP56 while simplifying installation.All devices feature plug-in designs with •Listed to UL 1638(strobe)and UL 464(horn) minimal intrusion into the back box,which make installations fast •Rated from—40°F to 151°F and foolproof while virtually eliminating costly and time-consuming •Horn rated at 88+dBA at 16 volts ground faults. •Rotary switch for horn tone and three volume selections All horns,strobes,and horn strobes use a universal mounting plate •Compatible with System Sensor synchronization protocol and with an onboard shorting spring that tests wiring continuity before legacy SpectrAlert products the device is installed,protecting devices from damage.In addition, field-selectable candela settings,automatic selection of 12-or 24- volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings SIGNALLING 0 :l v MEA LISTED 7125 15511H(horn strobes APPROVED approved 11251553:IRR cb,n strobes) 5401'(mlmes,horn strobes,horny chore strobes) 53�93(MItdoor anti alert strobes) 3023572 MFA65I/15{ 71M-1653.18a(nnms,domes) SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync.Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync-Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110,115,135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 17.5 V(12 V nominal)or 16 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5-high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mmW x 64 mm D) Horn Dimensions 5.6-L x 4.7"W x 1.31)(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"Lx5.1"Wx2.0"D(145mmLx130mmWx51 mm D) Ceiling-Mount Weatherproof Back Box Dimensions(SA-WBBC) 7.1"diameter x 20"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12V nominal only for 15 and 15/75 cd, Ass-5455-00I UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 - Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd( • 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 29/ Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela Horn and Horn Strobe Output(dBA) ratings must be reduced in accordance with this table, 8-17.5 16-33 24-Volt Nominal Strobe Output(cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-Temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non Temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8+ Coded Medium 78 78 85 85 90 90 97 98 150 150 9t Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7,8,and 9 arc not available on 2-wire horn strobe. 185 185 .W-03s6-001 SpectrAlert Advance Dimensions .-4.7'_. 6.6" ,,lot, Die. ---j.' is !! Wall-mount horn strobes Ceiling-mount horn strobes /1 / 2,0" Ole. IY\ / _ o o p, Q' ® o / "'cod 111—(71-11 Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Ceiling Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor PC2RK 2-Wire Horn Strobe,Standard cd,Red,Outdoor P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor PC2RHK 2-Wire Horn Strobe,High cd,Red,Outdoor P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor PC2WK 2-Wire,Horn Strobe,Standard cd,White,Outdoor P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor PC2WHK 2-Wire,Horn Strobe High cd,White,Outdoor P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor PC4WK 4-Wire,Horn Strobe,Standard cd,White,Outdoor P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor PC4WHK 4-Wire,Horn Strobe,High cd,White,Outdoor . P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor,120 V Ceiling Strobes Wall Strobes SCRK Strobe,Standard cd,Red,Outdoor SRK*} Strobe,Standard cd,Red,Outdoor SCRHK Strobe,High cd,Red,Outdoor SRHK*t Strobe,High cd,Red,Outdoor SCWK Strobe,Standard cd,White,Outdoor SWK*t Strobe,Standard cd,White,Outdoor SCWHK Strobe,High cd,White,Outdoor SWHK*t Strobe,I l igh cd,White,Outdoor Horns HRK Horn,Red,Outdoor Notes: "Add"-P"to model number for plain housing(no'FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),especially for use with weatherproof outdoor flush mounting plate,WFP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings. .SYSTEM02009 System Sensor. �_` SENSOR' 3825 Ohio Avenue•St.Charles, L 60174 Pmd cr speoficzwns subject,change rdthcut nrn¢e.ms¢rvsremsenvacnmfn _\`Y\,Yl Phone:800-SENSOR2•Fax:630-37/-6495 ".fens Nodal infnrrnmOn,inchiding the West ve,am d this data sheet. AM-MSF001.WOo.Yl l an SYSTEM SENSOR'` Selectable-Output Low Frequency Sounder and Low F Frequency Sounder Strobes for Wall E x : E Applications RAlert SpectrAlert°Advance audible visible notification products SPECT are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz t 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: 135, 150, 177,and 185 The wall-mount low frequency sounder,and low frequency sounder strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz± 10%and is of a square wave tone.Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming ground faults. • Listed for ceiling or wall mounting To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING 0 MEA t.�) LISTED APPROVEDapproved t��I 54011)sounder) 3047563 ME41452-05-E 7135-1653:0223 85512(strobes) 7125-1653'0224 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•Circuirm MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a • 411/16 x 411/16 x 21/s-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm Lx 119 mm Wx 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm L x 119 mmW x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Low Frequency Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC SpectrAlert Advance Dimensions 4.7 in. ► 2.5 in. ► . ■^� 4.7 in. N �1.3 ino. I'l °' ,I ,= I ��-_-=_ • lir, „ II I iii f „ :, 11 ,,,=2 [E, .._____:.. ; 6.4 in.:E., ® 5.6 in. NI) I. .)) ) , ..,._... , 2 = • �. 1. Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: "High cd"refers to strobes that include 135,150,177,and 185 candela settings. 6.1 ' SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ®2014 System Sensor. $ SENSOR' Phone:800-SENSOR2•Fax 630-377-6495 Produstsoeciilcallons subject to change without notice.Visltsystensensrn.cam "y K for current product hformation.ncluthng the latest version of this dale sheet. Y www.systemsensoccom AVDS16403.5/14 SYSTEM �$ SENSOR' Indoor Selectable- Output Strobes and Horn Strobes for - Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower mir, current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIeruuNG r > LISTED APPROVED 55512 FM approved except 7125-16530504 54011 for ALERT models 7135-16530503 3057383 • AVDS868-02•12/01/2017•Page 3 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor LSeries Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications • Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4'high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVD£868-02•12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Vohs FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 • PVOS868-02•1 210 1/2 01 7•Page 3 L-Series Dimensions 6.83'than1.3T(34.8 mm) 6 .diam. ' —� 2. (173 mm) (17577 mm) \\ (64 m mm) e --I 7.12 li e o O o81 1 1 C III IF A0545-03 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 4e. ]n mo ; ..� ,��° i_ ,J� �i• 0 miki,‘" ' Of,, / ;;'$,.;',.. -.:;,- --i'v,''':: .,';', rj y 10,1 is,, 1 �. f �1� 5V 1i- t*r � l • ,, 30494-0I A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865'Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". SYSTEM 02017 System Sensor. �� SENSOR' 3825 Ohio Avenue•St.Charles, IL Product speaca4on55ubjecttochargewMputwAce.Vsitsystemsensorcorn Phone.800-SENSOR2•Fax:630-377-6495 for current product reformation the 000000n of:Ps data sheet. AVDS858-02.12/01/2017